Validasi Metode Analisis Logam Aluminium, Barium, dan Besi dalam Plasma Darah Menggunakan ICPS - Ubaya Repository

VALIDASI METODE ANALISIS LOGAM ALUMINIUM,
BARIUM, DAN BESI DALAM PLASMA DARAH
MENGGUNAKAN ICPS
Gresia Stefani, 2016
Pembimbing : Indrajati Kohar dan Ratih

ABSTRAK
Pabrik kembang api menggunakan berbagai macam logam terutama logam
aluminium, barium, dan besi. Logam-logam tersebut dapat terhirup dan
terakumulasi dalam tubuh. Akumulasi logam tersebut dapat dianalisis dengan
menggunakan sampel darah yaitu plasma karena logam yang terakumulasi
berikatan dengan protein (albumin) dalam plasma darah. Metode analisis yang
akan digunakan adalah metode terapan yang diambil dari National Institute for
Occupational Safety and Health (NIOSH) Manual of Analytical Methods tahun
1994 mengenai Elements in Blood or Tissue. Validasi metode analisis logam
aluminium, barium, dan besi dalam plasma darah menggunakan ICPS penting
untuk dilakukan agar hasil analisis yang didapatkan dengan metode tersebut
merupakan hasil yang akurat dan presisi. Parameter validasi meliputi selektivitas,
batas deteksi (LLOD), batas kuantitasi (LLOQ), linieritas, akurasi dan presisi.
Dari penelitian yang dilakukan, logam aluminium dianalisis pada panjang
gelombang 394,401 nm dengan nilai r = 0,9993; nilai LLOD = 0,2029 bpj; nilai

LLOQ = 0,6765 bpj; dan rentang %Recovery = 103,57%-113,74% dengan nilai
KV = 3,34%. Logam barium dianalisis pada panjang gelombang 455,403 nm
dengan nilai r = 0,9994; nilai LLOD = 0,0149 bpj; nilai LLOQ = 0,0497 bpj; dan
rentang %Recovery = 94,18%-107,09% dengan nilai KV = 4,55%. Logam besi
dianalisis pada panjang gelombang 259,940 nm dengan nilai r = 0,9990; nilai
LLOD = 0,0736 bpj; nilai LLOQ = 0,2453 bpj; dan rentang %Recovery = 87,53%105,29% dengan nilai KV = 7,44%. Hasil penelitian menunjukkan bahwa metode
yang digunakan memenuhi persyaratan validasi untuk penelitian ini berdasarkan
batasan validasi yang ditentukan oleh USP dan ICH.

Kata Kunci : validasi metode, ICPS, plasma darah, aluminium, barium, besi

vi

VALIDATION OF ANALYTICAL METHOD OF
ALUMINUM, BARIUM, AND IRON METAL
IN BLOOD PLASMA USING ICPS
Gresia Stefani, 2016
Advisor : Indrajati Kohar and Ratih

ABSTRACT

The fireworks factory used many metals especially aluminum, barium, and iron
metal. The metals can be inhaled and accumulated in the body. The accumulation
of metal can be analyzed in blood sample which is blood plasma because metal
that accumulates can bind with protein (albumin) in blood plasma. The method of
analysis that will be used is the method from National Institute for Occupational
Safety and Health (NIOSH) Manual of Analytical Methods on 1994 about
Elements in Blood or Tissue. Validation of analytical method of aluminum,
barium, and iron metal in blood plasma using ICPS is important to do so that the
result of the analysis that was obtained through this method is accurate and
precision. Parameters of validation are selectivity, linearity, detection limit
(LLOD), quantitation limit (LLOQ), accuracy and precise. From a research
conducted by, aluminum is analyzed at wavelengths 394,401 nm with r value =
0,9993; LLOD = 0,2029 ppm; LLOQ = 0,6765 ppm; and the range of %Recovery
= 103,57% - 113,74% with KV = 3,34%. Barium is analyzed at wavelengths
455,403 nm with r value = 0,9994; LLOD = 0,0149 ppm; LLOQ = 0,0497 ppm;
and the range of %Recovery = 94,18% - 107,09% with KV = 4,55%. Iron metal is
analyzed at wavelengths 259,940 nm with r value = 0,9990; LLOD = 0,0736 ppm;
LLOQ = 0,0736 ppm; and the range of %Recovery = 87,53% - 105,29% with KV
= 7,44%. The results show that the methods used meet the requirements of
validation based on the validation determined by USP and ICH.


Keyword : validation method, ICPS, blood plasma, aluminum, barium, iron metal

vii

Dokumen yang terkait

Hubungan Antara Masa Kerja Dan Kadar Logam Timbal (pb) Dalam Darah Sopir Angkutan Umum Lin S Kotamadya Surabaya Dengan Metode Inductively Coupled Plasma Spectrometry (ICPS) - Ubaya Repository

0 0 1

Validasi Metode Analisis Penetapan Kadar Teofilin dalam Plasma Darah in Vitro secara Kromatografi Cair Kinerja Tinggi - Ubaya Repository

0 0 1

Validasi Metode Analisis Logam Berat Pb, Cu, Dan Zn Dalam Saus Tomat X Dari Pasar Tradisional L Di Kota Blitar Dengan ICPS - Ubaya Repository

0 0 1

Analisis Fe(II) dalam Kapsul dan Tablet Multivitamin Penambah Darah Produk X dan Z dengan Metode ICPS (Inductively Coupled Plasma Spectrometry) - Ubaya Repository

0 0 1

Analisis Fe(II) dalam Sirup Multivitamin X dan Y dengan Metode ICPS (Inductively Coupled Plasma Spectrometry) - Ubaya Repository

0 0 1

Pengaruh Interferensi Logam Magnesium, Besi, Krom Terhadap Pengamatan Kadar Logam Timbal Pada Panjang Gelombang 383,306nm Dengan Menggunakan ICPS (Inductively Coupled Plasma Spectrometer) - Ubaya Repository

0 0 1

Pengaruh Interferensi Logam Aluminium Dan Besi Terhadap Logam Kadmium Pada Panjang Gelombang 226,502nm Dan 228,802nm Yang Diamati Dengan Inductively Coupled Plasma Spectrometer - Ubaya Repository

0 0 1

Validasi Metode Destruksi Kering Penetapan Kadar Logam Arsen (Aa) dan Timbal (Pb) Dalam Udang Putih (Metapenacus Monocerus) Secara ICPS (Inductively Coupled Plasma Spectrometer). - Ubaya Repository

0 0 1

Pengaruh Interferensi Logam Magnesium dan Besi Terhadap Pengamatan Kadar Logam Timbal Pada Panjang Gelombang 283,306 nm Dengan Menggunakan ICPS (Inductively Coupled Plasma Spektrometer) - Ubaya Repository

0 0 1

Pengaruh Interferensi Logam Besi Dan Aluminium Terhadap Logam Kalsium Pada Panjang Gelombang 396,847nm Dan 422,673nm Yang Dianalisis Dengan Inductively Coupled Plasma Spectrometer - Ubaya Repository

0 0 1