Correlation between the occlusal vertical dimension and the pupil rima oris distance among Sundanese population | Akhma | Padjadjaran Journal of Dentistry 13657 30087 2 PB
Padjadjaran Journal of Dentistry 2017;29(2):630-137.
Correlation between the occlusal vertical dimension and the
pupil rima oris distance among sundanese population
Nur Emalina Akhma bt. Muhamad Shafree*, Tauik Sumarsongko*, Rasmi Rikmasari*
*Department of Prosthodontics, Faculty of Dentistry Universitas Padjadjaran, Indonesia
ABSTRACT
Introduction: Among the most complex restorative challenges for a dentist is that related to determine
the occlusal vertical dimension (OVD). Objective methods of determining the OVD ofers signiicant
advantages because no radiographs or other special measuring devices are required. Previous review said
that the OVD is similar to the pupil-rima oris distance among the population of India. The purpose of this
study was to compare whether there was diferences between the OVD and the pupil-rima oris distance
among Sundanese population. Method: This study was an analytical cross sectional approach. A total of
ifty Sundanese students of Faculty of Dentistry, Universitas Padjadjaran who have fulilled all criteria
were chosen randomly to be measured the OVD and the pupil-rima oris distance. Result: Results showed
that there was no signiicant diference between the OVD and the pupil-rima oris distance (α=5%). There
were strong correlations between the OVD and the pupil-rima oris distance (p
Correlation between the occlusal vertical dimension and the
pupil rima oris distance among sundanese population
Nur Emalina Akhma bt. Muhamad Shafree*, Tauik Sumarsongko*, Rasmi Rikmasari*
*Department of Prosthodontics, Faculty of Dentistry Universitas Padjadjaran, Indonesia
ABSTRACT
Introduction: Among the most complex restorative challenges for a dentist is that related to determine
the occlusal vertical dimension (OVD). Objective methods of determining the OVD ofers signiicant
advantages because no radiographs or other special measuring devices are required. Previous review said
that the OVD is similar to the pupil-rima oris distance among the population of India. The purpose of this
study was to compare whether there was diferences between the OVD and the pupil-rima oris distance
among Sundanese population. Method: This study was an analytical cross sectional approach. A total of
ifty Sundanese students of Faculty of Dentistry, Universitas Padjadjaran who have fulilled all criteria
were chosen randomly to be measured the OVD and the pupil-rima oris distance. Result: Results showed
that there was no signiicant diference between the OVD and the pupil-rima oris distance (α=5%). There
were strong correlations between the OVD and the pupil-rima oris distance (p