Institutional Repository | Satya Wacana Christian University: Comparison Study of Beryllium and Lithium Target System for Beam Shaping Assembly Used in Boron Neutron Capture Therapy

COMPARISON STUDY OF BERYLLIUM AND LITHIUM
TARGET SYSTEM FOR BEAM SHAPING ASSEMBLY USED IN BORON
NEUTRON CAPTURE THERAPY
David Harendza1, Suryasatriya Trihandaru1, Slamet Santosa2 and Yohannes Sardjono2
1

Physics Department, Faculty of Science and Mathematics,
Satya Wacana Christian University
Jalan Diponegoro 52-60, Salatiga, Indonesia
2
Center of Science and Accelerator Technology, National Nuclear Energy Agency
Jalan Babarsari 21, Yogyakarta, Indonesia

ABSTRACT
Boron neutron capture therapy (BNCT) is a selective targeting cancer therapy method that
worked by radiating epithermal neutron beams to a tumor which has been injected by boron10 compound. For this method to work there are two key elements, first the boron-10
compound and second the irradiating neutron beam used must be at epithermal energy level.
The neutron source used in this research is 13 MeV 1mA cyclotron that is still being
developed by Indonesia National Nuclear Energy Agency. This paper focuses in beam
shaping assembly (BSA) target system. BSA target system is used to convert the proton
produced from cyclotron into neutron. IAEA produces a recommendation for BNCT neutron

beam quality, one of them is epithermal neutron flux that is higher than 109 �/��2 . To fulfill
this requirement it is absolutely crucial that the neutron flux in the target system produces the
highest neutron flux possible before moderation. In this paper simulation is conducted to find
the best target system and thickness for cyclotron 13 MeV that can produce the highest
neutron flux before moderation using MCNPX. From the simulation beryllium produces
higher neutron flux compared to lithium. Beryllium neutron flux peaks at 1250 μm with
neutron flux of 4.87E+12 �/��2 and lithium neutron flux peaks at 4000 μm with flux
3.53E+12 �/��2 .
Keywords: bnct, cyclotron, beam shaping assembly, target, mcnpx

Dokumen yang terkait

Comparison Study of Beryllium and Lithium Target System for Beam Shaping Assembly Used in Boron Neutron Capture Therapy

0 3 8

PERANCANGAN PEMANDU BERKAS NEUTRON HASIL REAKSI PROTON 30 MeV PADA TARGET BERILIUM SEBAGAI SUMBER NEUTRON PADA BORON NEUTRON CAPTURE THERAPY (BNCT) MENGGUNAKAN SOFTWARE MCNPX.

0 0 18

Institutional Repository | Satya Wacana Christian University: Optimasi Sudut Penyinaran Boron Neutron Capture Therapy (BNCT) pada Kanker Paru-Paru Menggunakan Simulasi MCNPX

0 0 1

Institutional Repository | Satya Wacana Christian University: Optimalization Design of Beam Shaping Assembly as A BNCT Cancer Treatment Facility using D-T Reaction Neutron Generator

0 0 1

Institutional Repository | Satya Wacana Christian University: Beam Shaping Assembly (BSA) Design Based D-D Neutron Generator 2,45 MeV For BNCT Treatment Facility

0 0 2

Institutional Repository | Satya Wacana Christian University: Beam Shaping Assembly (BSA) Design Based D-D Neutron Generator 2,45 MeV For BNCT Treatment Facility

0 0 1

ANALISIS FLUKS NEUTRON PADA BEAM PORT TEMBUS RADIAL REAKTOR KARTINI UNTUK FASILITAS UJI IN VIVO DAN IN VITROBORON NEUTRON CAPTURE THERAPY (BNCT).

0 0 2

Strathprints Institutional Repository id. pdf

0 1 23

A CONCEPTUAL DESIGN OF NEUTRON COLLIMATOR IN THE THERMAL COLUMN OF KARTINI RESEARCH REACTOR FOR IN VITRO AND IN VIVO TEST OF BORON NEUTRON CAPTURE THERAPY - e-Repository BATAN

0 0 8

OPTIMIZATION OF BIOLOGICAL SHIELD FOR BORON NEUTRON CAPTURE CANCER THERAPY (BNCT) AT KARTINI RESEARCH REACTOR

0 0 10