From the File Format list, select the log format.

9-26 Oracle Fusion Middleware Administrators Guide for Oracle Web Cache To remove a time from the schedule list, select the time, and then click Remove . The value moves to the left list, where you can modify it. See Section 9.8 for instructions on immediately rolling over log files.

d. In the Rollover by Size field, enter the maximum size of the log file size at

which rollover occurs. Specify 0 for unlimited size.

e. In the Retention by Time field, specify how long to keep log files before

purging the oldest ones. In the Every field, enter the quantity and from the list of Hours, Days, Weeks, Months , Years, select the duration. A quantity of 0 means unlimited time, which means Oracle Web Cache does not retain files based on time.

f. In the Retention by Size field, enter the total size of all log files before purging

oldest ones. Specify 0 for unlimited size. This value must be larger than the value you specify for the Rollover Size field. If neither Retention by Time or Retention by Size is set, then log files can grow without limits. The log files could end up consuming all available space on the disk where this file is located.

g. Click OK.

6. Click Apply and restart Oracle Web Cache. See

Section 2.13 .

9.4 Configuring Access Logs

To configure access log settings: 1. Navigate to the Web Cache Home page in Fusion Middleware Control. See Section 2.6.2 .

2. From the Web Cache menu, select Administration and then Access Logs.

The Access Log Configuration page displays.

3. Specify the following settings for each cache in the Cache-Specific Settings table:

a. In the Directory field, enter the directory in which to write access logs.

By default, the event log is stored in the following directories: UNIX ORACLE_INSTANCEdiagnosticslogsWebCachewebcache_name Windows ORACLE_INSTANCE\diagnostics\logs\WebCache\webcache_name b. Click Enable Logging? to enable logging; deselect to disable logging. c. Click Enable Buffering? to enable buffered logging; deselect the check box to disable buffered logging. Weekly 1. Add a time by selecting a day of the week, and entering values in the hours and minutes fields. The default 0 means at the start of the week. 2. Click Add. 3. From the Time Style list, select either Local or GMT Greenwich Mean Time