Testing for Temperature rise
SNI 7368-2007
i
5.3 Stability test 5.3.1 When supporting the flask with Ø 200 mm and height 130 mm at the plane
having slope 10° from horizontal, both the appliance and the flask shall not be fallen over or shifted.
a Put the appliance at the slope plane 10° from horizontal b Put the flask with the specified dimension on the grid of the appliance
c The flask and the appliance shall not shift, fall or tumble
Figure 5 Appliance stability test 5.3.2 When the product supporting a flask with Ø 200 mm and height 130mm
containing water whose surface is at 10 mm from the tip of the flask was shifted 15 mm from the centre of the grid, the flask and the appliance shall not fall over or
tumble a Put the appliance on a horizontal plane
b Place the flask having dimension as specified above containing water as high as 120 mm from the bottom of the flask
c Shift the position of the flask from the centre of the grid with offset 15 mm outward d The flask and the appliance shall not fall over or tumble
Figure 6 The position of appliance and the flask
SNI 7368-2007
15 of 15