2-4 Oracle Fusion Middleware Installation Guide for Oracle Data Integrator
Figure 2–1 Repository Creation Utility Select Components Screen
4. On the Custom Variables screen, provide the following information as shown in
Figure 2–2 :
Component Variable Description
Master Repository ID A specific ID for the new Master Repository. Master
Repository ID values must be between 0 and 899. Default value is 001.
Supervisor Password Password of the supervisor user. You must confirm
this password on the following line. Work Repository Type
Specify how the Work Repository will be used:
■
Use Development D for creating a development repository. This type of repository
allows management of design-time objects such as data models and projects including interfaces,
procedures, etc. A development repository also includes the run-time objects scenarios and
sessions. This type of repository is suitable for development environments.
D is the default work repository type.
■
Use Runtime R for creating an execution repository: This type of repository only includes
run-time objects scenarios, schedules and sessions. It allows launching and monitoring of
data integration jobs in Operator Navigator. Such a repository cannot contain any design-time
artifacts. Designer Navigator cannot be used with it. An execution repository is suitable for
production environments.
Installing Oracle Data Integrator 2-5
Figure 2–2 Repository Creation Utility Custom Variables Screen
5. Click Next to continue through the remaining screens as described in Repository
Creation Utility Screens in the Oracle Fusion Middleware Repository Creation Utility Users Guide.
Work Repository ID A specific ID for the new Work Repository. Default
value is 001. Work Repository Name
A unique name for the Work Repository. Default is WORKREP.
Work Repository Password Provide a password for the Work Repository.
Note: This version of Repository Creation Utility RCU does not
perform extensive validation on the user entries of Repository ID and Repository Type.
Master Repository ID values must be between 0 and 899 and Work Repository ID values must be between 0 and 899. Repository Type
value must be either D Development or R Runtime.
When incorrect values are entered for either of these, RCU fails during the repository creation process with the following error:
RCU-6135: Error while trying to execute Java action If you receive this error, go back to the
Repository Creation Utility Custom Variables Screen
and provide the correct values.
Component Variable Description