Daily and Common Maintenance

  Read this instruction manual attentively and keep this operating handbook well for future reference uses

  INSTRUCTION MANUAL ENGLISH PACKING LIST RES-ED440H-W RES-ED450H-W RES-ED480H-W RES-ED4100H-W

  CORPORATION ELECTRIC STORAGE WATER HEATER RIT-0003-154 NO. NAME

  UNIT (Pcs)

  1

  1

  2

  1

  3

  4

  5

  2

  1

  2 Electric Water Heater Instruction Manual Hanging Bolt Pressure Relief Valve Hook

  012313 Indonesia

  PT. BAHAGIA INTI TAMA Jakarta - Indonesia

  Troubleshooting Remedy Methods Problem Causes

  Check electricity source

  1. No power or power plug is and fixing plug must be not connected well good.

  CATALOG Adjust the temperature

  2. Too low temperature control to be the highest adjustment temperature.

  I n d i c a t o r l a m p n o t Before Use..........1

  3. ELCB not yet switch on Switch on the ELCB lighting

  4. The interior wire material Product’s Features..........1 damaged Request to After Sales

  5. Indicator lamp damaged Part Names..........2 Service for repair.

  6. Heating element damaged Specification..........3

  7. Water is over heated Dimension..........3

  1. Deficient heating time. Keep on heating Installation..........4~6

  2. Mix water valve for hot Adjust the mixed water water too low valve for hot water to be Installation Notice..........6 high.

  No hot water coming out

  3. Temperature-controller Operating Instructions..........7 malfunction Request to After Sales Service for repair.

  Daily and Common Maintenance..........7

  4. Heating element damaged Electrical Diagram..........8

  1. Water tap is turned off Turn on the water tap

  2. Water pressure is too low Add water pump Troubleshooting..........9

  No water coming out

  3. Pipe connection is not Correctly connect it Packing List ..........Back Cover connected properly according to diagram’s requirements

  1. The various mouth’s Hermetically seal the connection are not connection mouth well hermetically sealed Water leakage from tank

  2. The tank leakage Request to After Sales Service for repair.

  1. ELCB damaged Request to After Sales ELCB can’t reset Service for repair.

  2. Electric leakage

  Operating Instructions Part Names

  To start using, open the tap at heater outlet and then inlet valve to fill in the

  l

  tank, when the tank fulfilled, water will come steadily out of the tap. Close the outlet tap now.

  Wattage Selector Switch

  Plug in the power supply and press reset of the ELCB switch till indicator

  l goes on.

  Turn on power knob and select which wattage will use (500W, 1000W,

  l 1500W selectable).

  Select maximal water temperature with turn temperature knob clockwise to

  l

  low, medium or high temperature. (if after selected max water temperature the lamp indicator not goes on please select water temperature to be higher). Hot water operations: After the electrical water heater normally works and

  l

  the heats for a long period of time, you can use the hot water in the tank, you

  Machine body

  need mixed water valve to mixing hot water and cold water, as your proper temperature after finishing uses, shut off the mixed water valve.

  Cautions: Plug

  When adjusting the water temperature of the water exiting mouth, the Ø shower must not spray directly to the human body; you should test the

  Power source wire water temperature first to avoid burning or damages. with electricity

  Temperature setting: According to your required temperature, rotate the

  leakage protection Ø

  temperature adjusting knob by the clockwise direction. You can select to

  Temperature

  use the heating temperatures with grades in the temperature ranges of

  selector switch

  thirty to seventy five degrees Celsius from closing to the low, medium and

  Temperature high bands or from low to high. indicator

  Indicator lamp Power selecting: This unit offers three power band for your selections.

  Ø

  Hot water Pressure-relief valve

  Band 1: 500W, Band 2 : 1000W, Band 3 : 1500W.

  outlet pipe Drainage pipe joint Daily and Common Maintenance

  Frequently checking the connection of power source’s plug and the outlet is

  l in good condition. The plug’s outlet is well connected the ground or not.

  When it isn’t operated for a long period of time, typically in the low

  l

  temperature zones, you must empty the tank to avoid the water freeze in the tank which will cause the tank damage. In order to assure the electrical water heater work with high efficiency, you

  l

  had better clean the heating parts once a year. Remove the water dirt’s deposits accumulated on the electrical heating parts and the tank base.

  Electrical Diagram Before Use

  Ultra thick, micro hole polyurethane foaming technique, superior thermal retardation, power/energy saving.

  Power Selection Thermostat Element Element Indicator lamp Thermo

  C Product's Features

  This heaters are advanced style of our product, so please refer to the manual to use it. Safe:

  l For families, companies, hotel, beauty parlor and other service places. l

  Closed structure, can provide hot water for toilet, kitchen and other places.

  l

  5. Multifunction:

  l Adjustable heating temperature between 30 - 80 . l Three power selection (500W, 1000W, 1500W).

  4. Convenience:

  l

  Thank you for using Rinnai electric storage water heater . We would like to invite you to read this manual carefully before using and pay attention to the security characteristics and installation instructions especially.

  3. Energy saving:

  Tank with titanium enameled, good toughness, high strength, prolong its life.

  l Advanced durable outer shell. l

  2. Durable:

  Automatic over temperature protection device and over pressure protection device.

  l

  Reliable heating element advanced stainless heater, with electricity leakage protection device.

  l

  1.

  Keep this instruction manual well for future reference.

  Breaker ELCB L N E

RES-ED440H-W RES-ED450H-W RES-ED480H-W

  l

  Hand-rinsing basin E F G B C D A H

  Water inlet valve Shower Tap water pipe Mixed water valve Pressure-relief pipe

  Diagram 5 Mono-directional security valve

  Hot water outlet Cold water inlet Power source wire with electricity leakage protection RES-ED4100H-W

  Machine body Connection mouth for pipe

  Dimension Dimension

  1118 263 580 442 227 G ½”

  430 958 263 420 442 227 G ½” 430

  A B C D E F G H 380 380 801 685 238 238 316 200 392 392 202 202 G ½” G ½” 100 100 100 100

  Installation Notice RES-ED440H-W RES-ED450H-W RES-ED480H-W RES-ED4100H-W MODEL

  The power plug must be properly grounded and it is prohibited to use the tap water pipe line as grounding. In the power plug, the nul line shall not be connected the ground wire. To prevent electric shock, the ground wire shall not be electrified.

  l

  If don't comply to above items and cause some accident, our company won't hold any responsibilities to the direct loss or indirect caused by that.

  40L

  0.70

  l

  In order to prevent accident, only use the accessories our company offer and couldn't changed or replace without any notice.

  Security caution: l

  The wall where electric water heater hang on should be firm, and can hold two times as the weight of the electric water heater fully filled with water.

  IPX4 Specification l The water inlet and outlet pipe should not be connected in reverse. l

  24 Hours

  Rated capacity Rated voltage Rated pressure Rated temperature Rated power Water proof degree Socket Heating effeciency Structure type Installation method Heat Loss in (kWh)

  Horizontal Model

  500W, 1000W, 1500W (Selectable) 220V ~ 10A > 90 % Hermetical type water storage style

  0.7 mPa 30 ~ 80 C (Selectable) ° °

  1.4 100L 1.6 220V

  80L

  1.05

  50L

  If the accessory is damaged, should be notify our after sales service department to maintain and replace with the accessories our company offer.

  (Note: This installation is only for indicating diagram reference). l

  Note: the direction of hanging bolt must be installed correctly, perpendicular to ground and face up, shouldn't slantwise .

  l

  The electric water heater must be installed by professional of our after sales service department or installed by qualified technician.

  l Installing way is hanging on the walls. l

  Select proper height and position, then determine the installation position at the same level.

  l

  Drill two corresponding holes with distance as diagram 1, then insert the bolts and firmly fixed, hang the electrical water heater lastly.

  l

  l Confirm whether it already fixed firmly or not.

  l

  Installation Firm Cement Wall Hanging Bolt

  Diagram 1

  0.7MPa Water-drainage Position Water-drainage Spanner 0.7MPa Fixed screw nail

  Pressure-relief mouth Hot water outlet pipe Mono-directional security valve

  Cold water inlet pipe Pressure relief hold Water entering Mouth’s copper nut

  Mixed water valve’s regulation handle Hot water-exiting mouth’s nut

  Power source wire with electricity leakage protection Shower

  Installation refer to diagram 2. This diagram is an installation sketch, the specification is according to user's circumstance.

  ” nut in the proper position of water inlet and outlet pipes in order to install and knock down easily. Confirm the position where need water, connect the cold water outlet pipe and hot water outlet pipe respectively. Note: the pipes of electric water heater should be not too long to reduce heat losses.

  Connect the drainage pipe with pressure relief valve, (refer to diagram 4), connect the other end of the drainage pipe with drainage mouth to avoid the room becomes dirty. It may exist water drops fall down at the pressure relief mouth sector when water heater is operating and heating the water, this is normal because of the water in the tank expanding when heated. In any conditions, this pressure relief hole must not be blocked. You can drain the drops to drainage, the drainage pipe connecting with pressure relief valve should be installed facing down.

  If want to distribute the hot water to many outlet, you can refer to diagram 5.

  l

  Confirm proper position, fix the shower hand hanger on the wall, connect the shower hand tube into pipe line.

  l

  Turn on the mix-water valve connected with electric water heater and rotate to water outlet pipe direction (left), then turn on tap water valve, filling tank. It indicates the tank is fully filled with water when the water flow out from water outlet mouth continuously, then close the mix-water valve. Check whether every connection joint is leaking or not.

  l

  Plug the power source when tank is fully filled with water, there is no leakage and electricity meet the requirement.

  l

  l

  1/2

  Usage of mixed water valve: Connection: Add seal to screw cap of cold water inlet mouth and hot water outlet mouth, connect to mixed water valve's water inlet mouth and hot water outlet pipe (refer to diagram 2 and 3), confirm fixed and no water leakage. Use: After connection according to diagram 2 and 3, pull the handle up and down to adjust the water flow, pull to up, the water flow is bigger, pull to down is smaller. Turn left and right to adjust the water temperature, turn left for higher temperature and turn right for lower temperature.

  Hot water outlet Pressure-relief valve of cold water inlet Cold water

  Water outlet (connect to shower hand) Temperature turn to high

  Diagram 3 Diagram 4 l Install the pressure relief valve and other accessories refer to diagram 2.

  Use seal to avoid water leakage.

  l

  We suggest to install extra G

  Diagram 2 230mm

DAFTAR PACKING

  Unit (Pcs) NO. Nama

  INDONESIA

  1

  1 Electric Water Heater

  2

  1 Petunjuk Penggunaan

  3

  2 Baut Gantungan

  4

  1 Pressure Relief Valve

ELECTRIC STORAGE WATER HEATER

  5

2 Hook

  RES-ED440H-W RES-ED450H-W RES-ED480H-W RES-ED4100H-W

PETUNJUK PENGGUNAAN

  PT. BAHAGIA INTI TAMA Jakarta - Indonesia Baca buku petunjuk ini dengan seksama dan simpan dengan baik sebagai referensi dimasa

  012313 yang akan datang

  Cara Mengatasi Masalah Penyebab Masalah Cara Mengatasi

  Periksa aliran listrik dan

  1. Tidak ada aliran listrik p e r b a i k i p e m a s a n g a n atau pemasangan steker steker ke stop kontak listik kurang sempurna.

  DAFTAR ISI Atur temperature control

  2. Pengaturan suhu terlalu kesuhu yang lebih tinggi rendah lagi.

  Lampu indicator tidak Sebelum Menggunakan..........1

  3. ELCB belum dinyalakan Nyalakan ELCB menyala

  4. Ada kabel yang putus Fitur Produk..........1

  5. Indicator lampu rusak H u b u n g i L a y a n a n Nama Bagian..........2

  6. Heating element rusak Purna Jual kami

  Spesifikasi..........3

  7. Temperatur air telalu panas Dimensi..........3

  1. Waktu pemanasan kurang. Panaskan kembali Pemasangan..........4~6

  2. Bukaan kran pencampur Atur bukaan kran untuk air panas terlalu pencampur untuk air Catatan Saat Pemasangan..........6 kecil. panas lebih besar lagi Air panas tidak keluar

  3. Temperature-control tidak Petunjuk Penggunaan..........7 berfungsi H u b u n g i L a y a n a n Purna Jual kami.

  Perawatan Rutin Harian..........7

  4. Heating element rusak Diagram Listrik..........8

  1. Kran air belum dibuka Buka kran air

  2. Tekanan air terlalu rendah Gunakan pompa air Cara Mengatasi Masalah..........9

  Air tidak keluar

  3. Sambungan pipa tidak Perbaiki sambungan Daftar Packing..........Cover Belakang tersambung dengan benar pipa sesuai dengan diagram.

  1. Seal sambungan tidak Sambungan pipa diseal rapat dengan rapat Air bocor dari tangki

  2. Tangki bocor H u b u n g i L a y a n a n Purna Jual kami.

  1. ELCB rusak H u b u n g i L a y a n a n ELCB tidak bisa me-reset Purna Jual kami.

  2. Ada kebocoran listrik

  Nama Bagian Petunjuk Penggunaan

  Untuk memulai penggunaan, buka kran air panas lalu buka kran air masuk ke

  l

  pemanas, biarkan air terus mengalir, saat tangki sudah penuh, air akan keluar dari kran air panas dan tutup kran air panas.

  Tombol pengatur watt Pasang steker listrik dan tekan tombol reset yang terdapat pada ELCB dan l lampu indicator pada ELCB akan menyala.

  Putar tombol power dan pilih watt (daya listrik) yang akan kita gunakan

  l (500W, 1000W, 1500W dapat diatur/dipilih).

  Pilih suhu maksimal air dengan memutar tombol pengatur suhu searah jarum

  l

  jam ke posisi low, medium dan high temperature (bila setelah memilih suhu air maksimal lampu indicator pada water heater tidak menyala, silakan pilih suhu air lebih tinggi lagi). Pengoperasian air panas: Setelah water heater bekerja normal dan air sudah

  l

  dipanaskan pada waktu yang lama (sampai lampu indikator water heater

  Body mesin

  padam). Air panas dapat digunakan dengan menggunakan kran mixing untuk mencampur air panas dan dingin sesuai dengan yang kita inginkan. Setelah digunakan tutup kembali kran mixing.

  Perhatian: Steker

  Saat mengatur suhu air jangan sampai shower langsung mengenai tubuh Ø kita, pertama kita harus mencoba suhu air untuk mencegah kulit terbakar.

  Steker listrik

  Temperatur e setting: Sesuai suhu yang anda inginkan, putar tombol Ø

  dengan pencegah

  pengatur suhu searah jarum jam, anda dapat memilih suhu dengan cakupan

  kebocoran listrik suhu dari 30 - 75 C dari off ke low, medium dan high, atau dari low ke high.

  Tombol pengatur suhu Indikator

  Pemilihan daya listrik: Water heater ini menawarkan 3 pilihan daya listrik Ø

  temperatur Lampu indikator yang dapat dipilih: 500W, 100W, dan 1500W.

  Pressure-relief valve Pipa air panas Saluran pembuangan

  Perawatan Rutin Harian

  Periksa sambungan listrik secara berkala, apakah sambungan dalam kondisi

  l baik, steker listrik tersambung dengan ground atau tidak.

  Ketika water heater tidak dipergunakan dalam waktu yang lama, khususnya

  l

  didaerah yang suhu nya rendah, untuk menghindari air membeku didalam tangki yang akan menyebabkan kerusakan pada tangki, setelah selesai digunakan air didalam tangki harus dikosongkan.

  k

  Untuk menjaga ele trik water heater bekerja dengan efesiensi yang tinggi,

  l

  sebainya heating element dibersihkan setahun sekali, bersihkan kotoran dari endapan air kotor yang menempel diheating element dan permukaan tangki.

  Diagram Listrik Sebelum Menggunakan

  4. Kenyamanan:

  Power Selection Thermostat Element Element Indicator lamp Thermo

  C Fitur Produk

  Pemanas air ini merupakan model yang canggih, jadi mohon untuk membaca buku petunjuk dengan seksama untuk menggunakannya.

  l

  Untuk keluarga, perusahaan, hotel, salon kecantikan serta tempat jasa lainnya.

  l

  Struktur tertutup bisa memberikan air panas untuk toilet, dapur maupun tempat lainnya.

  l

  6. Multifungsi:

  l Pengaturan suhu pemanas pada range 30 - 80 .

  Dilengkapi reservasi mode dengan dua periode ON dan OFF sehingga dapat menghemat energi.

  Kami ucapkan terima kasih anda telah menggunakan storage water heater listrik Rinnai. Kami mohon anda untuk membaca manual ini secara seksama sebelum anda menggunakan produk storage water heater listrik ini. Mohon untuk memberi perhatian pada karakteristik keamanan serta pada cara pemasangan. Dan simpan dengan baik buku petunjuk penggunaan ini, sebagai referensi dimasa yang akan datang.

  l

  Lapisan polyurethane yang tebal dengan daya sekat panas yang baik dan hemat energi.

  l

  3. Hemat Energi:

  Tangki terbuat dari enamel titanium yang kuat serta usia pakai yang panjang.

  l Bagian luar water heater yang kuat dan tahan lama. l

  2. Daya tahan:

  Perlindungan dari suhu yang terlalu tinggi, serta perlindungan dari tekanan yang berlebihan.

  l Elemen pemanas yang bagus dengan fitur anti kebocoran listrik. l

  1. Aman:

  Breaker ELCB L N E

  40L

  l

  430 958 263 420 442 227 G ½” 430

  380 380 801 685 238 238 316 200 392 392 202 202 G ½” G ½” 100 100 100 100

  MODEL A B C D E F G H

  Hand-rinsing basin RES-ED440H-W RES-ED450H-W RES-ED480H-W RES-ED4100H-W

  Water inlet valve Shower Tap water pipe Mixed water valve Pressure-relief pipe

  Diagram 5 Mono-directional security valve

  Steker listrik dengan pencegah kebocoran listrik

  Pipa air panas Pipa air dingin

  Catatan Saat Pemasangan Body mesin Koneksi ke pipa air panas

  .

  S t e k e r l i s t r i k h a r u s m e m i l i k i g r o u n d y a n g b a i k d a n d i l a r a n g menghubungkan ground ke pipa air, pada stop kontak line nul jangan dihubungkan dengan grounding . U ntuk menghindari sengatan listrik kabel ground jangan dialiri listrik

  l

  Kami tidak akan bertanggung jawab atas kecelakaan yang terjadi sebagai akibat jika tidak memenuhi aturan diatas, serta semua kerugian langsung maupun tidak langsung yang diakibatkannnya.

  Jika aksesories rusak, harus menghubungi layanan purna jual kami untuk mendapatkan aksesories yang kami sediakan.

  0.70

  l

  Untuk mencegah terjadinya kecelakaan, gunakan hanya aksesories yang disediakan oleh perusahaan kami, dan tidak bisa dirubah atau diganti tanpa pemberitahuan.

  Perhatian untuk keamanan: l

  Dinding untuk menggantung water heater harus kokoh dan sanggup menahan dua kali berat water heater saat penuh berisi air.

  Dimension Dimensi l Pemasangan pipa air panas dan dingin jangan sampai terbalik. l

  IPX4 Spesifikasi

  Kapasitas air Voltase Tekanan air maksimal Suhu air maksimal Daya listrik Tingkat kekedapan air Soket Efesiensi panas Jenis struktur Metode pemasangan Energi yang hilang dalam 24 (kWh)

  Horizontal Model

  500W, 1000W, 1500W ( ) dapat diatur 220V ~ 10A > 90 % Hermetical type water storage style

  0.7 mPa 30 ~ 80 C ( ° ° dapat diatur)

  1.4 100L 1.6 220V

  80L

  1.05

  50L

  1118 263 580 442 227 G ½” E F G B C D A H

  Penggunaan kran mixing

  l Pemasangan

  Koneksi: Tambahkan packing pada

  Pressure-relief v alve

  kedua pipa air, hubungkan dengan

  Saluran air panas saluran air dingin

  Water heater ini harus dipasang oleh tenaga terlatih

  l 230mm

  kran (lihat diagram 2 dan 3) atau orang yang ditunjuk oleh servis center kami. pastikan tidak ada kebocoran. Pemasangan dengan cara digantung ditembok.

  l Air dingin

  Diagram 1 P e n g g u n a a n : S e t e l a h s e m u a

  Pilih ketinggian serta posisi yang cocok dan

  l pastikan pada posisi yang rata.

  terhubung sesuai dengan diagram, gerakan tuas kran naik dan turun Bor dua lubang yang sesuai dengan jarak seperti

  l

  d i a g r a m 1 , m a s u k a n b a u t d a n k e n c a n g k a n , untuk mengatur aliran air. Ke atas Saluran air keluar kemudian gantungkan water heater.

  (terhubung ke shower) Suhu lebih

  untuk air yang lebih besar dan ke

  panas

  Perhatikan: arah gantungan harus dipasang dengan

  l b a w a h u n t u k a i r l e b i h k e c i l .

  benar, tegak lurus terhadap lantai dan tidak boleh Gerakan ke kiri untuk suhu lebih miring. tinggi dan ke kanan untuk suhu

  Baut gantungan Diagram 3

  Pastikan lagi apakah water heater sudah terpasang

  l lebih rendah.

  dengan benar.

  Tembok semen

  Hubungkan pressure relief valve dengan pipa pembuangan (lihat diagram

  l

  Pasang over pressure relief valve dan aksesoris lainnya sesuai dengan

  l

  4), hubungkan pipa pembuangan dengan lubang pada kran agar ruangan diagram 2. Gunakan seal untuk mencegah kebocoran. tidak kotor. Mungkin ada tetesan air pada lubang buang kran, saat pemanas

  Kami sarankan menggunakan water mur G1/2" tambahan pada pipa air masuk

  l

  dinyalakan dan mulai memanaskan air. Itu adalah proses yang normal dan keluar, untuk memudahkan pemasangan dan pada saat membuka. karena air yang ada didalam tangki mengembang saat dipanaskan. Pada Tentukan posisi untuk air serta hubungkan pipa air dingin dan air panas. kondisi apapun, saluran pembuangan dari kran ini tidak boleh tertutup dan harus dipasang menghadap ke bawah. Catatan: Usahakan agar pipa air panas tidak terlalu panjang agar tidak kehilangan banyak panas.

  Setelah posisi benar, pasang shower dan hubungkan dengan pipa air.

  l

  Pemasangan mengacu pada diagram 2. Diagram ini adalah sketsa

  l

  Buka kran air panas dan buka kran air dingin untuk mengisi air ke water

  l pemasangan, untuk spesifikasi tergantung pada masing-masing pengguna.

  heater. Ketika air sudah mulai keluar dari kran air panas, tutup kran dan perhatikan apakah ada kebocoran.

  Diagram 2

  Hubungkan koneksi listrik ketika water heater sudah terisi penuh dengan

  l

  air, dan sudah tidak ada kebocoran serta listrik sudah sesuai yang

  (Catatan: Instalasi ini dibutuhkan. adalah sebagai diagram petunjuk untuk

  Steker listrik

  Jika menginginkan air panas untuk beberapa titik, silahkan mengacu pada

  l referensi). dengan pencegahan diagram 5. kebocoran listrik

  Fixed Screw Nail Koneksi ke pipa air panas Water-drainage Position Pressure-relief valve

  Pipa air panas 0.7MPa 0.7MPa Saluran pembuangan Kran mixing Koneksi ke pipa air dingin

  Shower Pipa air dingin Pressure-relief Water-drainage Spanner Mouth

  Diagram 4