BA.Adendum BAB X Perpres 54 Th. 2010

BAB X
SPESIFIKASI TEKNIS
Spesifikasi pengadaan alat Kesehatan BP2 GAKI
No
1

Nama barang
USG

2

Single channel
Pipette 1 - 10mL

3

Multi Chanel
Pipette (8) 10100µL

Spesifikasi
System

Weight: 3250 grams
Screen: 8.4”
Alphanumeric keyboard and touchpad
Integrated loudspeaker
Interchangeable battery
Long autonomy
Intuitive user interface.
Imaging modes
B, B + B
B + M Mode
CFM: Color Flow Mapping
PW: Pulses Wave Doppler
Zoom
Cineloop
Texs and annotations
Protocols
Measurements and tables
Storing of clips and images
DICOM.
Connectivity:

RJ 45
Composite Video
USB
DVI.
Clinical Applications:
- Abdominal, Gynecology, obstetrics, Musculoskeletal, Superficial and Vascular..
Accessories :
Rigid Transport Case,
Trolley ( original ) ,
Thermal Printer Co- lor,
1 Multifrequency Convex Probes (360), (2,5 ; 3,0;3,5;4,0 and 5,0 MHz )
1 Multifrequency Linier Probe (L738P) ( 3,5 ; 5,0; 6,0; 7,5 ; 9,0 ; 10,0 MHz )
Most advanced materials: PerfectPiston system, made of Fortron; Autoclaveble ; IvD
Confirmity; CE Certificate; resistant to heat, acids and alkalies, mildew, bleaches,aging,
sunlight and abrasion; two button operation; 4 digit display and magnifying shape
Most advanced materials: PerfectPiston system, made of Fortron; Autoclaveble ; IvD
Confirmity; CE Certificate; resistant to heat, acids and alkalies, mildew, bleaches,aging,
sunlight and abrasion; two button operation; 4 digit display and magnifying shape; 8
chanel;volume10 µL: systematic errror ± 3.0 % and random error ± 2.0 %; Volume 50 µL
: siytematic error ± 1.0 % and random error ± 0.8 % ; Volume 100 µL: systematic error ±

0.8 % and random error ± 0.3 %.

4

Fume hood

Unique hot zone baffles capture fumes quickly
The tapered fiberglass exhaust collar reduces airflow turbulence,
static pressure loss, noise level and increases face velocity
Perfect pitch profile. The gentle pitch of the hood profile enchanes visibility
Tri wall constuction and chain and sprocket sash system for maximum durability

Jumlah
1

2

1
1


Sash stop limits sash movement beyond 457 mm (18”).
When raised above this height, sash will automatically
and gentle full back to safe level (ESCO’s CreepDown mechanism.
Sash keylock available to keep sash in place at full open position for equipment loading,
or at full close position to restrict access into hood.
Constant volume / high performance concept eliminates the need
for complex VAV system
The frontier Acela fume hood delivers outstanding containment
(less than 0.05 ppm, as manufactured) down to 60 fpm face velocity at
both 18” restricted and full open sash openings, tested inhouse
in accordance to the ASHRAE-110 and EN14175-3 test protocols.
Independenly certified by Tintschl Engineering, Germany, to comply
with the requirements of the EN14175 fume hood test standart.
External dimension (mm) : 1220 x 900 x 1521
Internal dimension(mm) : 996 x 672 x 1240
Maximum sash opening : 740 mm (29.1”)
Exhaust volume/static pressure required face velocity of 0.3m/s(60fpm)
at 457 mm(18”) sash opening : 541 cmh@14.3Pa31cfm@ 0.06 “ WG
Outer exhaust outlet diameter (mm) : 305 (12”)
4” worktop, phenolic resin, 1 cut out for oval drip-cut on left (std)

EBA base cabinet for 4” fume hood
Blower PP 030 : inlet : 250 mm / outlet diameters : 9.8”
Motor : 1450 rpm
Power consumption : 1.5 kw
220-240 VAC 50 Hz, 1 phase
5

Centrifuge
portable ( 8) hole

Compact and practical centrifuge for small sample volume.
Fitted as standard with an angel rotor for 8 tubes up to a volume of15 mL
Attaning max RCF of 3,461, the EBA 20 is the ideal choice for a medical practice
accept wide variety of commercial tubes
Even glass tubes can be accommodated withough adapter
Adapters for a selection of additional tube are available on request
max capacity :in an angel rotor : 8 x 15 mL
Max speed (RPM) : 6000min -1
Max RCF : 3461
Dimension (H x W x D): 216 x 231 x 292 mm

Weight : approx 4 kg
Refrigeration : Air cooling
Rotor: Angel rotor for 8 x 15 ml tubes inclusive

1