Open the Load Plan Editor and go to the Steps tab.

14-12 Oracle Fusion Middleware Developers Guide for Oracle Data Integrator Set Advanced Options for Run Scenario Steps You can set the following properties for Run Scenario steps in the Property Inspector: ■ Priority : Priority for this step when the scenario needs to start in parallel. The integer value range is from 0 to 100 100 being the highest priority. Default is 0. The priority of a Run Scenario step is evaluated among all runnable scenarios within a running Load Plan. The Run Scenario step with the highest priority is executed first. ■ Context : Context that is used for the step execution. Default context is the Load Plan context that is defined in the Start Load Plan Dialog when executing a Load Plan. Note that if you only specify the Context and no Logical Agent value, the step is started on the same physical agent that started the Load Plan, but in this specified context. ■ Logical Agent : Logical agent that is used for the step execution. By default, the logical agent, which is defined in the Start Load Plan Dialog when executing a Load Plan, is used. Note that if you set only the Logical Agent and no context, the step is started with the physical agent corresponding to the specified Logical Agent resolved in the context specified when starting the Load Plan. If no Logical Agent value is specified, the step is started on the same physical agent that started the Load Plan whether a context is specified for the step or not. Open the Linked Object of Run Scenario Steps Run Scenario steps can be created for packages, integration interfaces, variables, procedures, or scenarios. Once this Run Scenario step is created, you can open the Object Editor of the original object to view and edit it. To view and edit the linked object of Run Scenario steps: 1. In the Steps Hierarchy table of the Steps or Exceptions tab, select the Run Scenario step.

2. Right-click and select Open the Linked Object.

The Object Editor of the linked object is displayed. Change the Test Variable in Case Steps To change the variable that is used for evaluating the tests defined in the WHEN statements: 1. In the Steps Hierarchy table of the Steps tab or Exceptions tab, select the Case step.

2. In the Step Properties section of the Properties Inspector, click Lookup Variable.

This opens the Modify Case Step Dialog.

3. In the Modify Case Step Dialog, click Lookup Variable and follow the instructions

in Table 14–3 corresponding to the Case step. Define the Exception and Restart Behavior Exception and Restart behavior can be set on the steps in the Steps Hierarchy table. See Section 14.2.4, Handling Load Plan Exceptions and Restartability for more information. Regenerate Scenarios To regenerate all the scenarios of a given Load Plan step, including the scenarios of its child steps: