CHECK LIST PREVENTIVE MAINTENANCE MECHANICAL ELECTRICAL

  Protelindo Site ID Protlindo Site Name Date Time

WIB / WITA / WIT

Grounding Measurement : Ohm ( < 1 Ohm )

  Grounding Well : Ohm ( < 1 Ohm ) Tower Leg : Ohm ( < 1 Ohm ) Fence : Ohm ( < 1 Ohm ) Genset Tank : Ohm ( < 1 Ohm )

  

LIGHTING

FENCE

ENVA STATUS

PT NOKIA SIEMENS NETWORK

  ( HARI )

  Obstruction Light Failure : OK NOK N/A Remark : ( uninstalled, undetected ), …………. Grounding System : OK NOK N/A Remark : ( uninstalled, undetected ), …………. Fence Break : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

  Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), …………. Site Cleaning : OK NOK Remark : ( cleaning for grass / garbage )…………………… Flume Cleaning : OK NOK Remark : …………………… Paving Block or Gravel : OK NOK Remark : …………………… Barbared Wire : OK NOK Remark : …………………… Fence Door (Swing/Sliding) : OK NOK Remark : …………………… ENVA Check Respons Lightening Alarm : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

  Yard Lamp Condition : OK NOK N/A Remark : ( broken, cracked, unshielded), …………. Site Photo Sensor : OK NOK N/A Remark : ( sensor respon checking ), …………. Yard Lamp Shield : OK NOK N/A Remark : ( lamp shield checking broken / no ), …….

  4 Unit Yard Lamp Amount (Mercury & TL) :

  

TOWER

LIGHTING

Tower Lamp (OBL) Amount :

  0,33 0,36 N/A

  ……………………….

  

GROUNDING

……………………….

  : JAW-CJV-0004-D-P : TEMBALANG (SEMARANG) : 06/03/2012 : 10:18:00 AM

  Base Service

CHECK LIST PREVENTIVE MAINTENANCE

MECHANICAL ELECTRICAL

  BAR grounding tower : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… BAR grounding well : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… Down conductor Cable : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… Bolt Connection : OK NOK Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… Tower Type : SST Monopole Triangle Pole Mini Tower Painting Condition : OK NOK Remark : ( tower loosen paint 70 % ), GALVANIS Construction Condition : OK NOK Remark : ( paving down/ tower leg cracked ), …………. Tower Cleaning : OK NOK Remark : ( cleaning from spider nest / bee / etc ), …………. Tower Lamp / OBL : OK NOK N/A Remark : ( broken, cracked, unshielded), …………. Photo Sensor : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….

  Grounding Status : Lightening Rod : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...

1 Unit Tower Lamp (OBL) Condition : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….

INSPECTION BY

CHECK LIST PREVENTIVE MAINTENANCE

  Protelindo Site ID Date Protlindo Site Name Time WIB / WITA / WIT Operator

  B. R, S & T Indicator Lamps are lit : OK NOK NA MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..…… KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……

  Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) :

  V Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record : AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH

  :

  OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition ) COS : OK NOK N/A Remark : ( clean, neat, broken ) PLN Power Supplied : kVA MCB input :

  MCB Condition : OK NOK NA

  1 Phase : A pcs

  3 Phases : A pcs COS : A PLN ID : Seal

  KWH Record : OK NOK NA ( Good Sealed ), ………..…… Terminal / OKA : OK NOK NA ( Good Sealed ), ………..…… MCB : OK NOK NA ( Good Sealed ), ………..……

  MCB in the KWH 'ON' Position

  A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..……

  Measurement 0,39 0,37 0,53

  211 378

  Control Box : Ohm ( < 1 Ohm ) External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm ) Base Frame Condition : OK NOK N/A Remark : ...............................

  

OUTDOOR TYPE

KWH ELECTRICAL MEASUREMENT

  217 371

  216 373

  35037

  

ELECTRICAL VISUAL CHECK

PLN VISUAL CHECK

  52-3040397908

  23 ……………… ………………

  35

  3

  40

  Dynabolt Condition : OK NOK N/A Remark : ............................... Base Frame Foundation : OK NOK N/A Remark : ...............................

  Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...

  Equipment Type

  : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

  :

  Indoor Outdoor AC Amount

  :

  2 unit AC Mark : Daikin National Others / PANASONIC 1,5 PK Broken AC YES NO YES NO YES NO YES NO Power 1,5 1,5 Pressure

  70

  70 Current Max Current Measurement AC Indoor Condition OK NOK OK NOK OK NOK OK NOK Pipe Condition OK NOK OK NOK OK NOK OK NOK Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A Switch Contactor OK NOK OK NOK OK NOK OK NOK AC Temperature Setting OK NOK OK NOK OK NOK OK NOK Room Temperature : Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK Shelter Roof : OK NOK N/A Remark : ( leak, broken ), ………….

  Dinding Shelter

  : OK NOK N/A Remark : ( cracked, leak, broken ), ………….

  Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), …………. Room Cleaning : OK NOK Leak Remark : …………………… Roof Cleaning : OK NOK Leak Remark : …………………… Benzoic Spreading

  :

  OK NOK Remark : ( cleaning for grass / garbage )…………………… Door Hinge Lubrication : OK NOK Remark : …………………… Shelter Foundation : OK NOK Remark : …………………… Heat Detector

  Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), …………. Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

  

EXHAUST FAN

SHELTER

Alarm System

GROUNDING

  6,72 8,28

  Tenant

  : JAW-CJV-0004-D-P : 06/03/2012 : TEMBALANG (SEMARANG) : 10:18:00 AM

  : FLEXI

  

AIR CONDITIONER

Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4

  AC Status PK Psi

  According with data signed at AC Outdoor

  Ampere Leak / Not Leak Leak / Not Leak

  Operation test switch < 24

  o

  C 20,7

PLN FUNCTION TEST

CHECK LIST PREVENTIVE MAINTENANCE

  : JAW-CJV-0004-D-P : 06/03/2012 : TEMBALANG (SEMARANG) : 10:18:00 AM

  Protelindo Site ID Date Protlindo Site Name Time WIB / WITA / WIT Operator

  Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...

  

EXHAUST FAN

SHELTER

Alarm System

GROUNDING

  C

  o

  Operation test switch < 24

  Ampere Leak / Not Leak Leak / Not Leak

  According with data signed at AC Outdoor

  AC Status PK Psi

  

AIR CONDITIONER

Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4

  : ISAT

  Control Box : Ohm ( < 1 Ohm ) External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm ) Base Frame Condition : OK NOK N/A Remark : ...............................

  Measurement 0,37

  Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), …………. Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

  : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

  OK NOK Remark : ( cleaning for grass / garbage )…………………… Door Hinge Lubrication : OK NOK Remark : …………………… Shelter Foundation : OK NOK Remark : …………………… Heat Detector

  :

  Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), …………. Room Cleaning : OK NOK Leak Remark : …………………… Roof Cleaning : OK NOK Leak Remark : …………………… Benzoic Spreading

  : OK NOK N/A Remark : ( cracked, leak, broken ), ………….

  …………. unit AC Mark : Daikin National Others / …………….. Broken AC YES NO YES NO YES NO YES NO Power Pressure Current Max Current Measurement AC Indoor Condition OK NOK OK NOK OK NOK OK NOK Pipe Condition OK NOK OK NOK OK NOK OK NOK Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A Switch Contactor OK NOK OK NOK OK NOK OK NOK AC Temperature Setting OK NOK OK NOK OK NOK OK NOK Room Temperature : Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK Shelter Roof : OK NOK N/A Remark : ( leak, broken ), …………. Dinding Shelter

  :

  Indoor Outdoor AC Amount

  :

  Equipment Type

  Tenant

  • N/A

  V Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record : AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH

  212 212 212

  Dynabolt Condition : OK NOK N/A Remark : ............................... Base Frame Foundation : OK NOK N/A Remark : ...............................

  40

  1 …………… …………..

  35

  7,7

  N/A

  

ELECTRICAL VISUAL CHECK

PLN VISUAL CHECK

  2472

  

OUTDOOR TYPE

KWH ELECTRICAL MEASUREMENT

  :

  Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) :

  B. R, S & T Indicator Lamps are lit : OK NOK NA MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..…… KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……

  A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..……

  MCB in the KWH 'ON' Position

  KWH Record : OK NOK NA ( Good Sealed ), ………..…… Terminal / OKA : OK NOK NA ( Good Sealed ), ………..…… MCB : OK NOK NA ( Good Sealed ), ………..……

  3 Phases : A pcs COS : A PLN ID : Seal

  1 Phase : A pcs

  MCB Condition : OK NOK NA

  OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition ) COS : OK NOK N/A Remark : ( clean, neat, broken ) PLN Power Supplied : kVA MCB input :

PLN FUNCTION TEST

CHECK LIST PREVENTIVE MAINTENANCE

  Protelindo Site ID Date Protlindo Site Name Time WIB / WITA / WIT Operator

  Measurement 0,33 0,42

  :

  OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition ) COS : OK NOK N/A Remark : ( clean, neat, broken ) PLN Power Supplied : kVA MCB input :

  MCB Condition : OK NOK NA

  1 Phase : A pcs

  3 Phases : A pcs COS : A PLN ID : Seal

  KWH Record : OK NOK NA ( Good Sealed ), ………..…… Terminal / OKA : OK NOK NA ( Good Sealed ), ………..…… MCB : OK NOK NA ( Good Sealed ), ………..……

  MCB in the KWH 'ON' Position

  A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..……

  B. R, S & T Indicator Lamps are lit : OK NOK NA MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..…… KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……

  N/A

  Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) :

  

OUTDOOR TYPE

KWH ELECTRICAL MEASUREMENT

  212 213 212

  1311

  

ELECTRICAL VISUAL CHECK

PLN VISUAL CHECK

  N/A

  7,7

  16

  2 …………… ……………

  40

  V Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record : AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH

  Dynabolt Condition : OK NOK N/A Remark : ............................... Base Frame Foundation : OK NOK N/A Remark : ...............................

  Equipment Type

  Tenant

  :

  Indoor Outdoor AC Amount

  :

  …………. unit AC Mark : Daikin National Others / …………….. Broken AC YES NO YES NO YES NO YES NO Power Pressure Current Max Current Measurement AC Indoor Condition OK NOK OK NOK OK NOK OK NOK Pipe Condition OK NOK OK NOK OK NOK OK NOK Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A Switch Contactor OK NOK OK NOK OK NOK OK NOK AC Temperature Setting OK NOK OK NOK OK NOK OK NOK Room Temperature : Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK Shelter Roof : OK NOK N/A Remark : ( leak, broken ), …………. Dinding Shelter

  : OK NOK N/A Remark : ( cracked, leak, broken ), ………….

  Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), …………. Room Cleaning : OK NOK Leak Remark : …………………… Roof Cleaning : OK NOK Leak Remark : …………………… Benzoic Spreading

  :

  OK NOK Remark : ( cleaning for grass / garbage )…………………… Door Hinge Lubrication : OK NOK Remark : …………………… Shelter Foundation : OK NOK Remark : …………………… Heat Detector

  : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

  Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), …………. Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

  : JAW-CJV-0004-D-P : 06/03/2012 : TEMBALANG (SEMARANG) : 10:18:00 AM

  Control Box : Ohm ( < 1 Ohm ) External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm ) Base Frame Condition : OK NOK N/A Remark : ...............................

  : TSEL

  

AIR CONDITIONER

Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4

  AC Status PK Psi

  According with data signed at AC Outdoor

  Ampere Leak / Not Leak Leak / Not Leak

  Operation test switch < 24

  o

  C

  

EXHAUST FAN

SHELTER

Alarm System

GROUNDING

  Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...

PLN FUNCTION TEST

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Contractor : NOKIA SIEMENS NETWORK

PREVENTIVE MAINTENANCE

PHOTO REPORT

  Base Service Foto A - 1

  Foto A - 2

Tampak halaman site sebelum dibersihkan Tampak halaman site setelah dibersihkan

Foto A - 3

  Foto A - 4

Tampak tower bagian atas (tampak mounting & lampu halaman) Tampak tower bagian bawah (tampak pedestal/kaki tower)

Foto A - 5

  Foto A - 6

Tampak pagar / tembok Tampak paving block / gravel

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Contractor : NOKIA SIEMENS NETWORK

PREVENTIVE MAINTENANCE

PHOTO REPORT

  Base Service Foto B - 1

  Foto B - 2 Status grounding - Tampak lightning rod (Splitzen) Status grounding - Grounding ke Pagar Foto B - 5

  Foto B - 6

Pengukuran grounding - Grounding ke Pagar Pengukuran grounding - Grounding ke kaki tower

Foto B - 3

  Foto B - 4 Status grounding - Down Conductor cable Status grounding - Bolt Connection

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Contractor : NOKIA SIEMENS NETWORK

PREVENTIVE MAINTENANCE

PHOTO REPORT

  Base Service Foto C - 1

N/A

  Foto C - 2 Pengukuran grounding - Tangki genset (if any) Pengukuran grounding - Box control

  

Tampak Access Lease Area Site View - Tampak Atas (Sisi -1)

Foto C - 3 Foto C - 4

OBL - Berfungsi dengan baik Yard Lamp - Berfungsi dengan baik

  Foto C - 5 Foto C - 6

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Contractor : NOKIA SIEMENS NETWORK Site View - Tampak Atas (Sisi - 2) Safety Tools (Safety belt, helm, sepatu, sarung tangan)

  

PREVENTIVE MAINTENANCE

PHOTO REPORT

Base Service

  Foto D - 1 Foto D - 2

N/A

  Foto D - 5 Foto D - 6 Foto D - 3 Foto D - 4 Tampak warning sign board (if any)

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : FLEXI PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Indoor Foto A-1

  Foto A-2 Tampak Bagian Luar Shelter Tampak Bagian Dalam Shelter Foto A-3

  Foto A-4 Tampak Cable Tray Tampak Lampu di dalam shelter Foto A-6

  Foto A-5

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : FLEXI

Tampak Grounding di dalam shelter Tampak pondasi shelter

  PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Indoor Foto B-1

  Foto B-2 Foto B-5

  Foto B-6 Foto B-3 Foto B-4

Tampak Fire Extinguisher Tampak Panel Alarm

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : FLEXI Foto C-1

  Foto C-2 Tampak AC Indoor Tampak AC Outdoor PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Indoor

  Pengukuran - Tekanan AC Pengukuran - Temperature Shelter Foto C-5

  Foto C-6 Foto C-3 Foto C-4

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : FLEXI PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Indoor Foto D-1

  Foto D-2 Pengukuran - Tegangan T - N (Panel KWH) Pengukuran - Tegangan R - S (Panel KWH) Foto D-3

  Foto D-4 Pengukuran - Tegangan S - T (Panel KWH) Pengukuran - Tegangan R - T (Panel KWH) Foto D-5

  Foto D-6

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : FLEXI Pengukuran - Tegangan S - N (Panel ACPDB) Pengukuran - Tegangan T - N (Panel ACPDB)

  PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Indoor Foto D-1

  Foto D-2 Foto D-3

  Foto D-4 Pengukuran - Tegangan R - S (Panel ACPDB) Pengukuran - Tegangan S - T (Panel ACPDB) Foto D-5

  Foto D-6

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : FLEXI PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Indoor Foto E-1

  Foto E-2 Status grounding - Control Box Status grounding - External Grounding Bar Foto E-3

  Foto E-4

Status grounding - Internal Grounding Bar Pengukuran grounding - Control Box

Foto E-5

  Foto E-6

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : FLEXI Tampak Pole KWH Box Kondisi KWH Panel (Keadaan tertutup)

  PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Indoor Foto F-1

  Foto F-2 Foto F-5

  Foto F-6 Foto F-3 Foto F-4 Kondisi KWH Panel (Keadaan terbuka) Kondisi MCB KWH Meter

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : FLEXI PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Indoor Foto G-1

  Foto G-2 Kondisi segel pada MCB KWH meter KWH meter record Foto G-5

  Foto G-6 Foto G-3 Foto G-4

  ID Pelanggan

  Protelindo ID : JAW-CJV-0004-D-P Date Protelindo Name : TEMBALANG (SEMARANG) Tenant : ISAT PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto A-1

  Foto A-2

Tampak Kondisi Base Frame Tampak Kondisi Dyna Bolt

: 06/03/2012

  Foto A-3 Foto A-4 Tampak Pondasi Base Frame Pengukuran - Tegangan R - N (Panel KWH)

  Foto A-6 Foto A-5

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : ISAT

Pengukuran - Tegangan R - S (Panel KWH) Pengukuran - Tegangan S - T (Panel KWH)

  PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto B-1

  Foto B-2 Foto B-5

  Foto B-6 Foto B-3 Foto B-4

Pengukuran - Tegangan R - T (Panel KWH) Pengukuran - Tegangan G- N (Panel KWH)

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : ISAT Foto C-1

  Foto C-2 Pengukuran - Tegangan T - N (Panel ACPDB) Pengukuran - Tegangan R - S (Panel ACPDB) PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor

  

Pengukuran - Tegangan S - T (Panel ACPDB) Pengukuran - Tegangan R - T (Panel ACPDB)

Foto C-5

  Foto C-6 Foto C-3 Foto C-4

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : ISAT PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto D-1

  Foto D-2

Status grounding - External Grounding Bar Status grounding - Internal Grounding Bar

NA

  Foto D-3 Foto D-4 Pengukuran grounding - Control Box Pengukuran grounding - External Grounding Bar

  Foto D-5 Foto D-6

  NA

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : ISAT

Kondisi KWH Panel (Keadaan tertutup) Kondisi KWH Panel (Keadaan terbuka)

  PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto E-1

  Foto E-2 Foto E-5

  Foto E-6 Foto E-3 Foto E-4 Kondisi MCB KWH Meter Kondisi Segel pada Terminal KWH

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : ISAT Foto F-1

N/A

  Foto F-2 KWH meter record

  ID Pelanggan PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor

  Foto F-5 Foto F-6 Foto F-3 Foto F-4

  Protelindo ID : JAW-CJV-0004-D-P Date Protelindo Name : TEMBALANG (SEMARANG) Tenant : TSEL PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor : 06/03/2012 Foto A-1

  Foto A-2

Tampak Kondisi Base Frame Tampak Kondisi Dyna Bolt

Foto A-3

  Foto A-4 Tampak Pondasi Base Frame Pengukuran - Tegangan R - N (Panel KWH) Foto A-6

  Foto A-5

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : TSEL PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto B-1

  Foto B-2

Pengukuran - Tegangan R - S (Panel KWH) Pengukuran - Tegangan S - T (Panel KWH)

Foto B-3

  Foto B-4

Pengukuran - Tegangan R - T (Panel KWH) Pengukuran - Tegangan G- N (Panel KWH)

Foto B-5

  Foto B-6

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : TSEL PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto C-1

  Foto C-2 Pengukuran - Tegangan T - N (Panel ACPDB) Pengukuran - Tegangan R - S (Panel ACPDB) Foto C-3

  Foto C-4

Pengukuran - Tegangan S - T (Panel ACPDB) Pengukuran - Tegangan R - T (Panel ACPDB)

Foto C-5

  Foto C-6

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : TSEL PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto D-1

  Foto D-2

Status grounding - External Grounding Bar Status grounding - Internal Grounding Bar

NA

  Foto D-3 Foto D-4 Pengukuran grounding - Control Box Pengukuran grounding - External Grounding Bar

  Foto D-5 Foto D-6

  NA

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : TSEL PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto E-1

  Foto E-2

Kondisi KWH Panel (Keadaan tertutup) Kondisi KWH Panel (Keadaan terbuka)

Foto E-3

  Foto E-4 Kondisi MCB KWH Meter Kondisi Segel pada Terminal KWH Foto E-5

  Foto E-6

  Protelindo ID : JAW-CJV-0004-D-P Date : 06/03/2012 Protelindo Name : TEMBALANG (SEMARANG) Tenant : TSEL PREVENTIVE MAINTENANCE PHOTO REPORT Tenant Outdoor Foto F-1

N/A

  Foto F-2 KWH meter record

  ID Pelanggan

  Foto F-3 Foto F-4

  Foto F-5 Foto F-6