If an additional target is needed, click the Additional Target button on the Service

19-24 Developers Guide for Oracle Application Integration Architecture Foundation Pack If you have selected the AIAAsyncErrorHandlingBPELProcess service WSDL location in the MDS infrastructure library as the Error Handling Service Runtime Location value, perform the following post-service-generation task: a. Access the generated composite to update the location attribute of the binding.ws element within the reference element for AIAAsyncErrorHandlingBPELProcess. b. Update the location with the actual AIAAsyncErrorHandlingBPELProcess runtime location. For example, the location indicated in bold in Example 19–1 , must be updated. Example 19–1 Reference Element for AIAAsyncErrorHandlingBPELProcess reference ui:wsdlLocation=oramds:appsAIAMetaDataAIAComponents InfrastructureServiceLibraryV1wsdlsAIAAsyncErrorHandlingBPELProcess.wsdl name=AIAAsyncErrorHandlingBPELProcess ... binding.ws port=http:xmlns.oracle.comAIAAsyncErrorHandlingBPEL Processwsdl.endpointAIAAsyncErrorHandlingBPELProcessAIAAsyncError HandlingBPELProcess location=oramds:appsAIAMetaDataAIAComponents InfrastructureServiceLibraryV1wsdlsAIAAsyncErrorHandlingBPELProcess.wsdl xmlns:ns=http:xmlns.oracle.comsca1.0 ... reference

2. If an additional target is needed, click the Additional Target button on the Service

Option page to access the Create Additional Target dialog box, as shown in Figure 19–26 , where you can add another invocation for an application that cannot support the EBM through only one invocation. For example, take a scenario in which updating a Person in a participating application may require an invocation to both a Person and an Address service. Error Handling Service Runtime Location Designate the runtime location of the AIAAsyncErrorHandlingBPELProcess service. The default location is the common oramds: location. If you select the AIAAsyncErrorHandlingBPELProcess service WSDL location in the MDS infrastructure library, you must perform the post-service-generation task described following this table. If you select the actual runtime endpoint location value of AIAAsyncErrorHandlingBPELProcess, no post-service-generation task is required. Add Extensions Option to add extensions. If the Enable Extension option is enabled under the Target Service options, then this option is selected by default and is required. Extension WSDL Runtime Location WSDL of extension service. Generate custom fault policy Select to be able to create a custom fault policy. Additional Target Click to add an additional target. Certain participating applications require calls to more than one service interface to complete the necessary steps for message transformation message enrichment, and so on. Table 19–9 Cont. Service Option Elements Element Description Working with Service Constructor 19-25 Figure 19–26 Create Additional Target This dialog box contains the same attributes and features as the primary target dialog box, but consolidates the service details, fault details, and options. The details for the additional target are completed in the same manner discussed for the Target Service Details page, discussed in Section 19.2.4, Defining the Target Services .

3. Optionally, click the Save As button to save a service solution component request