X-Ray DR Imaging System 1. X-Ray Imaging Principle

 ISSN: 1693-6930 TELKOMNIKA Vol. 14, No. 3A, September 2016 : 224 – 228 225 2. X-Ray DR Imaging System 2.1. X-Ray Imaging Principle X-ray digital imaging technology is a new X-ray nondestructive testing technology that is developed in recent years. Compared with the traditional film type of test method, it is characterized of fast test speed, strong portability, high test sensitivity, test results managed easily, and small field radiation, etc. After X-ray passes through the tested object, the ray detector converts the X-ray test signals into digital signals that are received by the computer to form the digital image and stored in the computer according to certain format. The black level of images depends on the radiation exposure also called exposure. Since the ray intensity of defect parts and good parts is different, image corresponding parts will have the difference of black degree. The blackness difference of image adjacent area is defined as “contrast ratio” [1]. According to the different shapes of images formed by the contrast ratio, experimenters can judge the defects of equipment to reach the goal of defect state evaluation. 2.2. X-Ray DR Imaging System The industrial X-ray imaging principle is the same as the principle of X-ray, CT and security system. When penetrating the different objects, X-ray interacts with the matter. Due to the absorption and scattering, intensity is changed. The photosensitive material IP plate receives the signal of intensity change to form the common images [2, 3] through the signal processing. A complete set of test system, which is used in the test of switch devices, includes the radiation source, sensitive plate IP plate, CR scanner, image display system including the software of image processing analysis, the on-site mobile scaffold, mobile workstation, etc. The specific process sees the principle Figure 1. First connect the connecting line between components, set the test parameters through the control box. X-ray from the ray generator penetrates the tested part. After the part is subject to the sensitization of the IP imaging plate directly facing the back of the equipment, it is scanned by CR scanner to form the digital image. Figure 1. X-ray DR imaging principle

3. The Typical Defects of Switch Devices