42
4.3 Analisa Data
Berdasarkan data-data yang diperoleh dari hasil pengujian, maka dilakukan perhitungan untuk mendapatkan efisiensi generator arus searah
penguatan kompon kumulatif dan kompon diferensial. a. Untuk Generator DC Penguatan Kompon Panjang Kumulatif
1. Arus medan I = 0.17 A,
Tegangan terminal V = 122 Volt
P = V
t
x I
L
P = 122 x 4.83
P = 589,26 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 122 + 5 x 3,8 + 4,83 x 0,6 = 143,898 Volt
P = E
a
x I
a
P = 143,898 x 5 P = 719,49 watt
η =
P P
x 100
η =
V I E I
x 100
η =
589,26 719,49
x 100 η
= 81,899 2. Arus medan
I = 0.16 A, Tegangan terminal
V = 118 Volt P
= V
t
x I
L
P = 118 x 4,84
Universitas Sumatera Utara
43
P = 571,12 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 118 + 5 x 3,8 + 4,84 x 0,6 = 139,904 Volt
P = E
a
x I
a
P = 139,904 x 5 P = 699,52 watt
η =
P P
x 100
η =
V I E I
x 100
η =
571,12 699,52
x 100 η
= 81,644 3. Arus medan
I = 0.15 A, Tegangan terminal
V = 116 Volt P
= V
t
x I
L
P = 116 x 4,85
P = 562,6 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 116 + 5 x 3,8 + 4,85 x 0,6 = 137,91 Volt
P = E
a
x I
a
P = 137,91 x 5 P = 689,55 watt
Universitas Sumatera Utara
44
η =
P P
x 100
η =
V I E I
x 100
η =
562,6 689,55
x 100 η
= 81,589 4. Arus medan
I = 0.14 A, Tegangan terminal
V = 113 Volt P
= V
t
x I
L
P = 113 x 4,86
P = 549,18 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 113 + 5 x 3,8 + 4,86 x 0,6 = 134,916 Volt
P = E
a
x I
a
P = 134,916 x 5 P = 674,58 watt
η =
P P
x 100
η =
V I E I
x 100
η =
549,18 674,58
x 100 η
= 81,410
Universitas Sumatera Utara
45
Dengan melakukan perhitungan seperti di atas pada berbagai besar tegangan, maka akan diperoleh nilai E
a
, P
in
, P
out
dan efisiensi lainnya seperti pada tabel 4.5.
Tabel 4.5
Data Hasil Analisa Pengujian Generator DC Penguatan Kompon Panjang Kumulatif
amp volt
amp ohm
volt watt
watt η
0.17 122
4.83 30.0
143.898 589.26
719.49 81.899
0.16 118
4.84 27.9
139.904 571.12
699.52 81.644
0.15 116
4.85 25.4
137.91 562.6
689.55 81.589
0.14 113
4.86 24.2
134.916 549.18
674.58 81.410
0.13 104
4.87 20.6
125,922 506.48
629.61 80.443
0.12 102
4.88 19.7
123.928 497.76
619.64 80.330
0.11 97
4.89 18.2
118.934 474.33
594.67 79.763
0.10 87
4.9 16.8
108.94 426.3
544.7 78.263
0.09 84
4.91 16.0
105.946 412.44
529.73 77.858
0.08 78
4.92 14.4
99.952 383.76
499.76 76.788
0.07 64
4.93 11.3
85.958 315.52
429.79 73.412
0.06
`57 4.94
9.6
78.964 281.58
394.82 71.318
0.05
43 4.95
7.9
64.97 212.85
324.85 65.522
0.04
32 4.96
6.8
53.976 158.72
269.88 58.811
0.03
24 4.97
5.0
45.982 119.28
229.91 51.881
0.02
15 4.98
3.7
36.988 74.7
184.94 40.391
0.01
9 4.99
2.9
30.994 44.91
154.97 28.979
Universitas Sumatera Utara
46
b. Untuk Generator DC Penguatan Kompon Pendek Kumulatif 1. Arus medan
I = 0.17 A, Tegangan terminal
V = 124 Volt P
= V
t
x I
L
P = 124 x 4,83
P = 598,92 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 124 + 5 x 3,8 + 4,83 x 0,6 = 145,898 Volt
P = E
a
x I
a
P = 145,898 x 5 P = 729,49 watt
η =
P P
x 100
η =
V I E I
x 100
η =
598,92 729,49
x 100 η
= 82,101 2. Arus medan
I = 0.16 A, Tegangan terminal
V = 120 Volt P
= V
t
x I
L
P = 120 x 4,84
P = 580,8 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 120 + 5 x 3,8 + 4,84 x 0,6 = 141,904 Volt
Universitas Sumatera Utara
47
P = E
a
x I
a
P = 141,904 x 5 P = 709,52 watt
η =
P P
x 100
η =
V I E I
x 100
η =
508,8 709,52
x 100 η
= 81,858 3. Arus medan
I = 0.15 A, Tegangan terminal
V = 117 Volt P
= V
t
x I
L
P = 117 x 4,85
P = 567,45 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 117 + 5 x 3,8 + 4,85 x 0,6 = 138,91 Volt
P = E
a
x I
a
P = 138,91 x 5 P = 694,55 watt
η =
P P
x 100
η =
V I E I
x 100
η =
567,45 694,55
x 100
Universitas Sumatera Utara
48
η = 81,700
4. Arus medan I = 0.14 A,
Tegangan terminal V = 113 Volt
P = V
t
x I
L
P = 113 x 4,86
P = 549,18 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 113 + 5 x 3,8 + 4,86 x 0,6 = 134,916 Volt
P = E
a
x I
a
P = 134,916 x 5 P = 674,58 watt
η =
P P
x 100
η =
V I E I
x 100
η =
549,18 674,58
x 100 η
= 81,410
Universitas Sumatera Utara
49
Dengan melakukan perhitungan seperti di atas pada berbagai besar tegangan, maka akan diperoleh nilai E
a
, P
in
, P
out
dan efisiensi lainnya seperti pada tabel 4.6.
Tabel 4.6
Data Hasil Analisa Pengujian Generator DC Penguatan Kompon Pendek Kumulatif
amp volt
amp ohm
volt watt
watt η
0.17 124
4.83 31.0
145.898 598.92
729.49 82.101
0.16 120
4.84 28.7
141.904 580.8
709.52 81.858
0.15 117
4.85 25.9
138.91 567.45
694.55 81.700
0.14 113
4.86 24.3
134.916 549.18
674.58 81.410
0.13 106
4.87 21.4
127.922 516.22
639.61 80.708
0.12 103
4.88 20.2
124.928 502.64
624.64 80.473
0.11 99
4.89 19.5
120.934 484.11
604.67 80.061
0.10 89
4.9 17.8
110.94 436.1
554.7 78.619
0.09 86
4.91 16.4
107.946 422.26
539.73 78.235
0.08 78
4.92 14.6
99.952 383.76
499.76 76.788
0.07 66
4.93 11.8
87.958 325.38
439.79 73.985
0.06
58 4.94
10.3
79.904 286.52
399.52 71.716
0.05
45 4.95
8.4
66.97 222.75
334.85 66.522
0.04
35 4.96
7.6
56.976 173.6
284.88 60.937
0.03
27 4.97
5.5
48.982 134.19
244.91 54.791
0.02
18 4.98
4.1
39.988 89.64
199.94 44.833
0.01
10 4.99
3.3
31.994 49.9
159.97 31.193
Universitas Sumatera Utara
50
c. Untuk Generator DC Penguatan Kompon Panjang Diferensial 1. Arus medan
I = 0.17 A, Tegangan terminal
V = 155 Volt P
= V
t
x I
L
P = 155 x 4,83
P = 748,65 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 155 + 5 x 3,8 + 4,83 x 0,6 = 176,898 Volt
P = E
a
x I
a
P = 176,898 x 5 P = 884,49 watt
η =
P P
x 100
η =
V I E I
x 100
η =
748,65 884,49
x 100 η
= 84,641 2. Arus medan
I = 0.16 A, Tegangan terminal
V = 149 Volt P
= V
t
x I
L
P = 149 x 4,84
P = 721,16 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 149 + 5 x 3,8 + 4,84 x 0,6 = 170,904 Volt
Universitas Sumatera Utara
51
P = E
a
x I
a
P = 170,904 x 5 P = 854,52 watt
η =
P P
x 100
η =
V I E I
x 100
η =
721,16 854,52
x 100 η
= 84,393 3. Arus medan
I = 0.15 A, Tegangan terminal
V = 145 Volt P
= V
t
x I
L
P = 145 x 4,85
P = 703,25 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 145 + 5 x 3,8 + 4,85 x 0,6 = 166,91 Volt
P = E
a
x I
a
P = 166,91 x 5 P = 834,55 watt
η =
P P
x 100
η =
V I E I
x 100
η =
703,25 834,55
x 100
Universitas Sumatera Utara
52
η = 84,266
4. Arus medan I = 0.14 A,
Tegangan terminal V = 140 Volt
P = V
t
x I
L
P = 140 x 4,86
P = 680,4 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 140 + 5 x 3,8 + 4,86 x 0,6 = 161,916 Volt
P = E
a
x I
a
P = 161,916 x 5 P = 809,58 watt
η =
P P
x 100
η =
V I E I
x 100
η =
680,4 809,58
x 100 η
= 84,043
Universitas Sumatera Utara
53
Dengan melakukan perhitungan seperti di atas pada berbagai besar tegangan, maka akan diperoleh nilai E
a
, P
in
, P
out
dan efisiensi lainnya seperti pada tabel 4.7.
Tabel 4.7
Data Hasil Analisa Pengujian Generator DC Penguatan Kompon Panjang Diferensial
amp volt
amp ohm
volt watt
watt η
0.17 155
4.83 32.3
176.898 748.65
884.49 84.641
0.16 149
4.84 30.7
170.904 721.16
854.52 84.393
0.15 145
4.85 28.8
166.91 703.25
834.55 84.266
0.14 140
4.86 27.0
161.916 680.4
809.58 84.043
0.13 127
4.87 25.6
148.922 618.49
744.61 83.062
0.12 124
4.88 24.8
145.928 605.12
729.64 82.934
0.11 115
4.89 23.7
136.934 562.35
684.67 82.134
0.10 104
4.9 22.5
125.94 509.6
629.7 80.927
0.09 96
4.91 20.7
117.946 471.36
589.73 79.928
0.08 84
4.92 19.4
105.952 413.28
529.76 78.012
0.07 77
4.93 18.3
98.958 379.61
494.79 76.721
0.06
61 4.94
15.8
82.964 301.34
414.82 72.643
0.05
49 4.95
13.5
70.97 242.55
354.85 68.352
0.04
37 4.96
10.6
58.976 183.52
294.88 62.235
0.03
26 4.97
8.7
47.982 129.22
239.91 53.861
0.02
15 4.98
6.3
36.988 74.7
184.94 40.391
0.01
10 4.99
4.8
31.994 49.9
159.97 31.193
Universitas Sumatera Utara
54
d. Untuk Generator DC Penguatan Kompon Pendek Diferensial 1. Arus medan
I = 0.17 A, Tegangan terminal
V = 157 Volt P
= V
t
x I
L
P = 157 x 4,83
P = 758,31 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 157 + 5 x 3,8 + 4,83 x 0,6 = 178,898 Volt
P = E
a
x I
a
P = 178,898 x 5 P = 894,49 watt
η =
P P
x 100
η =
V I E I
x 100
η =
758,31 894,49
x 100 η
= 84,775 2. Arus medan
I = 0.16 A, Tegangan terminal
V = 151 Volt P
= V
t
x I
L
P = 151 x 4,84
P = 730,84 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 151 + 5 x 3,8 + 4,84 x 0,6 = 172,904 Volt
Universitas Sumatera Utara
55
P = E
a
x I
a
P = 172,904 x 5 P = 864,52 watt
η =
P P
x 100
η =
V I E I
x 100
η =
730,84 864,52
x 100 η
= 84,537 3. Arus medan
I = 0.15 A, Tegangan terminal
V = 147 Volt P
= V
t
x I
L
P = 147 x 4,85
P = 712,95 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 147 + 5 x 3,8 + 4,85 x 0,6 = 168,91 Volt
P = E
a
x I
a
P = 168,91 x 5 P = 844,55 watt
η =
P P
x 100
η =
V I E I
x 100
η =
712,95 844,55
x 100
Universitas Sumatera Utara
56
η = 84,417
4. Arus medan I = 0.14 A,
Tegangan terminal V = 140 Volt
P = V
t
x I
L
P = 140 x 4,86
P = 680,4 watt
E
a
= V
t
+ I
a
R
a
+ I
L
R
s
= 140 + 5 x 3,8 + 4,86 x 0,6 = 161,916 Volt
P = E
a
x I
a
P = 161,916 x 5 P = 809,58 watt
η =
P P
x 100
η =
V I E I
x 100
η =
680,4 809,58
x 100 η
= 84,043
Universitas Sumatera Utara
57
Dengan melakukan perhitungan seperti di atas pada berbagai besar tegangan, maka akan diperoleh nilai E
a
, P
in
, P
out
dan efisiensi lainnya seperti pada tabel 4.8.
Tabel 4.8 Data Hasil Analisa Pengujian Generator DC Penguatan Kompon
Pendek Diferensial
amp volt
amp ohm
volt watt
watt η
0.17 157
4.83 33.4
178.898 758.31
894.49 84.775
0.16 151
4.84 31.2
172.904 730.84
864.52 84.537
0.15 147
4.85 29.4
168.91 712.95
844.55 84.417
0.14 140
4.86 27.2
161.916 680.4
809.58 84.043
0.13 129
4.87 26.5
150.922 628.23
754.61 83.252
0.12 125
4.88 26.0
146.928 610
734.64 83.033
0.11 118
4.89 25.1
139.934 577.02
699.67 82.470
0.10 106
4.9 24.2
127.94 519.4
639.7 81.194
0.09 101
4.91 23.4
122.946 495.91
614.73 80.671
0.08 93
4.92 20.3
114.952 457.56
574.76 79.608
0.07 78
4.93 18.7
99.958 384.54
499.79 76.940
0.06
68 4.94
16.6
89.964 335.92
449.82 74.678
0.05
52 4.95
14.3
73.97 257.4
369.85 69.595
0.04
40 4.96
11.4
61.976 198.4
309.88 64.024
0.03
29 4.97
9.1
50.982 144.13
254.91 56.541
0.02
18 4.98
6.8
39.988 89.4
199.94 44.833
0.01
10 4.99
5.3
31.994 49.9
159.97 31.193
Universitas Sumatera Utara
4.4 Grafik Pengu