The thickness swelling Linear Expansion only apply for The determination of moisture The determination of Modulus Internal Bond the determination of The determination of wet bending The determination of screw holding

The Fifth Meeting of ACCSQ Wood Based PWG Brunei Darussalam, 11-12 July 2007

3. Moisture content

- The dimension of test pieces - The minimum number of test pieces is 1 pieces - The minimum number of test pieces is 4 pieces - 100 mm x 100 mm - The dimension is not specified but the minimum weight of the test piece is 20 g 1 2 3 4

4. The determination of density

- The dimension of test pieces the minimum number of test pieces is 1 piece - the minimum number of test pieces is 6 pieces - 100 mm x 100 mm 1 piece sample for - 50 mm x 50 mm both density and moisture content - The thickness is measured at 25 mm from - The thickness is measured at a point of inter- each corner 4 point section of the diagonals - The length and width are measured at along - The length and width are measured at two lines, two lines parallel to and at a distance of 25 mm parallel to the edges, along lines which pass from the edges through the center of opposite edges - The test pieces are conditioned before testing, at the humidity 65 ± 5 and temperature 20 ± 2°C

5. The thickness swelling

- The dimensions of test pieces the minimum number of test pieces is 1 piece the minimum number of test pieces is 6 pieces - 50 mm x 50 mm, to an accuracy of 0,05 mm - 50 mm x 50 mm, to an accuracy of 0,01 mm - Test condition - water temperature Fibre board 20° C, - water temperature 20 ± 1°C and pH 7 ± 1 Particle board 25°C - The duration of immersion: - The duration of immersion depend on panel types - 2 hours for LDF - 24 hours for MDF,HDF and Particle board

6. Linear Expansion only apply for

fibreboard - The dimensions of test pieces - 70 mm x 200 mm - 300 ± 1 mm x 50 ± 1 mm - Test methods - Based on water immersion - Based on the changes of relative humidity The Fifth Meeting of ACCSQ Wood Based PWG Brunei Darussalam, 11-12 July 2007 - Test condition - Immerse in water at room temperature for 24 hours applied for fibreboard only

7. The determination of moisture

resistance Not available Available under cyclic test conditions 8. The determination of surface soundness Not available Available 1 2 3 4

9. The determination of Modulus

Elasticity in bending and of bending strength - The distance between supports - 15 x thickness, with the minimum distance of - ≥ 20 x thickness 150 mm - the length of test pieces - 15 x thickness + 50 mm - ≥ 20 x thickness + 50 mm

10. Internal Bond the determination of

tensile strength perpendicular to the plane of the panel - test block - test block made from metal - test block could be made from metal, hardwood or hardwood plywood as long as they have an air dry density 600 kg m3

11. The determination of wet bending

strength - without conditioning - Conditioning of the test pieces before testing - cooling in water bath for 60 minutes - Cooling in water bath for 75 ± 25 minutes

12. The determination of screw holding

ability - The dimension of the test pieces - 50 mm x 100 mm - 75 ± 1 mm square The Fifth Meeting of ACCSQ Wood Based PWG Brunei Darussalam, 11-12 July 2007 - The dimension of screw - Diameter = 2.7 mm - for face withdrawal of screw , diameter = 2.9 mm, Length = 16 mm the length = not arranged, and the threated pitch the threated pitch = 11 mm 11 ± 0.5 mm - for edge withdrawal of screw , diameter = 4.2 mm, the length = not arranged, and the threated pitch 15 ± 0.5 mm - types of the screw only apllied in face withdrawal - applied for face and edge withdrawal the threated pitch 15 ± 0.5 mm - Expression of result - Expressed in kgf cm2 - only measured the maximum load, expressed in Newton N 1 2 3 4

13. Determination of Formaldehyde