min y °C Inulin Intake

Catalysts 2015 , 5 2299 Table 3. Cont. Run Temperature

T, °C Inulin Intake

C inulin , gmL CuCl 2 Concentration, C cat , M Reaction Time

t, min y

HMF wt. a y LA wt. b 20 160 0.10 0.010 65 23.5 5.2 21 160 0.05 0.005 120 13.6 4.7 22 170 0.10 0.015 65 18.4 14.8 23 180 0.15 0.005 120 1.0 21.6 24 170 0.05 0.010 65 25.4 13.3 25 170 0.10 0.010 65 20.7 10.7 26 180 0.05 0.005 10 30.3 6.5 27 180 0.05 0.015 120 2.0 28.9 28 180 0.15 0.015 120 3.4 27.1 29 170 0.10 0.010 65 19.9 10.6 30 180 0.05 0.005 120 4.4 27.8 a The yield of HMF is defined in Equation 3; b The yield of LA is defined in Equation 4. An extended version with more significant numbers for the coefficients to be used for among other reactor engineering studies is given in the supplementary information. The analysis of variance of the model is given in Table 4. The R-squared value for the model is 0.9764, indicating that the model fits the experimental data well. This is supported by a parity plot in Figure 10 showing the data and model points. Table 4. Analysis of variance of the preferred model for the yield of HMF. Source Sum of Squares df Mean Square F-value p-Value Prob F Model 1831.98 10 183.20 78.50 0.0001 significant A-T 11.81 1 11.81 5.06 0.0365 B-C load 247.48 1 247.48 106.04 0.0001 C-C cat. 0.92 1 0.92 0.39 0.5373 D-t 647.07 1 647.07 277.25 0.0001 AB 91.95 1 91.95 39.40 0.0001 AC 95.09 1 95.09 40.74 0.0001 AD 330.29 1 330.29 141.52 0.0001 CD 63.23 1 63.23 27.09 0.0001 C 2 10.46 1 10.46 4.48 0.0477 D 2 106.06 1 106.06 45.45 0.0001 Residual 44.34 19 - - - The yield of HMF as a function of the process conditions as predicted by the model is given in Figure 11. Clearly, the reaction time has a profound effect on the HMF yield, rationalised by assuming that HMF is an intermediate in the reaction sequence and ultimately will be converted to LA. Due to the interactions between the independent variables, it is difficult to draw general conclusions regarding the effect of individual independent variables on HMF yield. Catalysts 2015 , 5 2300 Figure 10. Parity plot for the HMF yield. a b Figure 11. Modelled HMF yield versus temperature and inulin intake at a 30 min and b 90 min batch time. The yield of LA as a function of the process conditions was also modelled, and the results are given in Table 5 and Equation 2. An extended version of Equation 2 with more significant numbers for the coefficients to be used among other reactor engineering studies is given in the supplementary information. The model describes the data points well, as is expressed by an R-squared value of 0.9651 and a parity plot Figure 12. y LA = 0.17T + 204.63C load + 303.82C cat − 1.2t − 1.38T·C load + 7.73 × 10 −3 T·t −25.22 2 Catalysts 2015 , 5 2301 Figure 12. Parity plot for LA yield. Table 5. Analysis of variance of the preferred model of LA. Source Sum of Squares df Mean Square F-Value p-Value Prob F Model 1538.79 6 256.47 106.20 0.0001 significant A-T 515.98 1 515.98 213.29 0.0001 B-C load 39.77 1 39.77 16.44 0.0005 C-C cat. 41.54 1 41.54 17.17 0.0004 D-t 644.84 1 644.84 266.56 0.0001 AB 7.60 1 7.60 3.14 0.0895 AD 289.06 1 289.06 119.49 0.0001 Residual 55.64 23 - - - The effect of two process conditions temperature and reaction time is presented in Figure 13. The LA yield increases at higher temperatures and longer reaction times, in line with the proposed reaction network Figure 6 where LA is the final product and HMF an intermediate. Figure 13. Modelled LA yield versus temperature and reaction time at a fixed inulin intake 0.1 gmL and CuCl 2 concentration 0.01 M. Catalysts 2015 , 5 2302 3. Experimental Section 3.1. Chemicals Inulin isolated from Dahlia tubers was purchased from Acros Organic Geel, Belgium. D -fructose 99 and levulinic Acid ≥97 were obtained from Acros Organic Geel, Belgium. Formic Acid and D -glucose were purchased from Merck KGaA Darmstadt, Germany. 5-Hydroxymethylfurfural HMF ≥99 was obtained from Aldrich Steinheim, Germany. Copper II chloride dihydrate ≥99 was bought from Acros Organics Geel, Belgium. All other salts were obtained from Acros Organics Geel, Belgium. All chemicals were used without purification. Deionized water was used to prepare the solutions. 3.2. Experimental Procedures 3.2.1. Catalyst Screening Experiments For the catalyst screening experiments, 2 mL of a solution of inulin 0.2 g inulin and the metal salt 5 mM in water was placed in a microwave tube. The tube was sealed with a plastic cap and placed in the microwave device CEM Synthesis Explorer 48, CEM, Matthews, NC, USA, heated to 170 °C, and stirred for 1 h at this temperature. After reaction, the tube was rapidly cooled; the contents were filtered, and the liquid phase was analysed by HPLC. 3.2.2. Experimental Design Experiments A similar experimental procedure as for the screening experiments was applied; the only difference being that solely copper II chloride was used as the catalyst. In addition, a broad window of process variables was used, viz temperatures in the range of 160–180 °C, initial inulin loadings in the range of 0.05–0.15 gmL, copper II chloride concentrations between 0.005–0.015 M, and reaction times between 10 and 120 min. 3.3. Analyses HPLC was used to identify and quantify the components in the liquid product after reaction. An Agilent technologies Santa Clara, CA, USA, 1200 series HPLC equipped with an isocratic pump, a Bio-Rad Hercules, CA, USA Aminex HPX-87H organic acid column 300 mm × 7.8 mm, and a Waters Milford, MA, USA 410 differential refractive index detector was used. Sulfuric acid in water 5 mM was used as the eluent with a constant flow rate of 0.55 mLmin. The column was operated at 60 °C. The analysis time for each sample was 60 min. The HPLC was calibrated with solutions of known compounds. Using the chromatogram peak area and the external calibration curve, the unknown concentrations of components in the liquid phase were determined. MALDI-TOFMS on a Voyager-DE PRO Applied Biosystems, Foster City, CA, USA was used to determine the molecular weight of the inulin sample. 2,5-Dihydroxybenzoic acid DHB was used as the matrix. Catalysts 2015 , 5 2303 The composition of the inulin sample, particularly the type and amount of C6-sugars, was determined by an acid-catalysed hydrolysis reaction. For this purpose, inulin 2.5 g was dissolved at 70 °C in 150 mL of water under stirring. The pH was adjusted to 1.4–1.6 by adding an aqueous HCl solution. Then, the solution was placed in a water bath for 30 min at 90 °C. A liquid sample was taken and analysed by HPLC. 3.4. Definitions The HMF yield y HMF is reported on a wt. basis and defined as follows: HMF HMF HMF ln 100 C M V y W     g HMFg inulin intake 3 The yield of LA is defined as: LA LA LA ln 100 C M V y W     g LAg inulin intake 4 In Equations 3 and 4, C HMF and C LA represent the concentration of HMF and LA, respectively molL as measured with HPLC, M HMF and ML A the molecular weight of HMF and LA g·mol, V the water intake L, and W in the intake of inulin on a weight basis g. The yield of HMF was converted from wt. to mol by assuming that inulin consists of linked glucosefructose units C 6 H 10 O 5 which react to HMF according to the following stoichiometry: C 6 H 10 O 5 → C 6 H 6 O 3 + 2 H 2 O 5 As such, the maximum yield of HMF is 78 wt. . Thus, the yield of HMF in mol may be calculated from the yield in wt. by dividing the latter by 0.78. 3.5. Statistical Modelling The yield of HMF as a function of process variables was modelled using the Design-Expert 7 software package Stat-Ease, Minneapolis, MN, USA using a standard expression given in Equation 6: 4 4 4 HMF 1 1 1 i i ij i j i i j y b b x b x x         6 The process variables x i : inulin intake, temperature, copper II chloride concentration, and reaction time are represented by the indices 1–4. The regression coefficients were obtained by statistical analyses of the data. Significance of factors was determined by their p-value in the ANOVA analyses. A factor was considered significant if the p-value is below 0.05, meaning that the probability of noise causing the correlation between a factor and the response is lower than 0.05. Insignificant factors were eliminated using backward elimination, and the significant factors were used to model the data.

4. Conclusions

An exploratory screening study revealed that metal salts may be used as catalysts for the reaction of inulin to HMF in water. Best results were obtained using CuCl 2 , giving an HMF yield of 30.3 wt. 39 mol at 180 °C, 0.05 g inulinmL, a 0.005 M CuCl 2 solution, and a reaction time of 10 min. The