PERBEDAAN KEBOCORAN MIKRO ANTARA KOMPOMER DENGAN KOMPOSIT SELF-ADHERED PADA RESTORASI KELAS V.

Perbedaan Kebocoran Mikro Antara Kompomer Dengan Komposit SelfAdhered Pada Restorasi Kelas V – Bagoes Prakoso Utomo – 160110090004

ABSTRAK
Perbedaan sistem adhesif dan karakteristik antara kompomer dengan
komposit self-adhered menghasilkan kekuatan ikat yang berbeda. Tujuan dari
penelitian untuk melihat perbedaan kebocoran mikro antara kompomer dengan
komposit self-adhered.
Jenis penelitian yang dilakukan adalah penelitian eksperimental laboratoris
dengan jumlah sampel 30 gigi premolar yang dibagi menjadi 2 kelompok dan
dipreparasi kavitas kelas V komposit. Kelompok I direstorasi menggunakan
kompomer merek Dyract® flowable compomer restorative. Kelompok II
direstorasi menggunakan komposit self-adhered merek Dyad™ Flow. Sampel
direndam dalam campuran larutan methylene blue 2% dan saliva buatan selama 24
jam di dalam inkubator dengan suhu 37°C. Setelah perendaman, gigi dipotong
arah vertikal sesuai sumbu panjang gigi. Pada potongan gigi tersebut dilakukan
pengamatan adanya penetrasi cairan di antara tepi kavitas gigi dengan bahan
restorasi. Pengamatan dilakukan menggunakan mikroskop stereo perbesaran 50
kali menggunakan skor 0-3. Data diuji statistik menggunakan uji kesamaan
proporsi.
Hasil penelitian diuji statistik dengan menggunakan uji kesamaan proporsi,
yang menunjukan hasil kebocoran mikro yang sama antara kompomer dengan

komposit self-adhered (p-value 0,271 > 0,05).
Simpulan dari penelitian ini adalah tidak terdapat perbedaan yang signifikan
antara kompomer dengan komposit self-adhered.

Kata kunci: kebocoran mikro, kompomer, komposit self-adhered.

iv 

Different of Microleakage Between Compomer and Composite Self-Adhered on
Class V Restorations – Bagoes Prakoso Utomo – 160110090004

ABSTRACT
The differences of adhesive systems and characteristics between compomer
and composite self-adhered produce different connective strength. The purpose of
this research was to see the different on microleakage between compomer with
composite self-adhered.
Type of the research is laboratory experimental research with total sample of
30 premolars divided into 2 groups and prepared for composite class V cavities.
Group I was restored with Dyract® flowable compomer restorative. Group II was
restored with composite self-adhered Dyad™ flow brand. Samples were restored

in a mixture of 2% methylene blue solution and artificial saliva for 24 hours in
incubator at temperature of 37°C. After soaking, tooth pieces were observed to
see the penetration of liquids among of the edge of cavities with the restoration.
Observations were made using a stereo microscope with magnification 50 times
based on the score of 0-3. Data was statically tested using same proportion.
The results of research are tested using statistic same proportion test, showed
results same microleakage between compomer and composite self-adhered (pvalue 0.271> 0.05).
Summary of the research there is no significant difference of microleakage
between compomer with composite self-adhered.

Keywords : mikroleakage, compomer, composite self-adhered.