Analisis Pengaruh Polutan Pada Isolator Kaca Terhadap Distribusi Tegangan Isolator Rantai
LAMPIRAN
HASIL PENGUKURAN SUHU DAN KONDUKTIVITAS
LARUTAN
Tabel A.1 Pengukuran Nilai Konduktivitas dan Suhu Larutan
NO
Larutan yang Diukur
Nilai Konduktivitas (μS/m)
Suhu (˚C)
1
Air
111
27
2
50 gram NaCl
190
27
3
200 gram NaCl
251
27.2
4
550 gram NaCl
356
27
5
100 gram CaCO3
170
27.2
6
500 gram CaCO3
226
27.2
7
900 gram CaCO3
311
27
8
80 gram C
181
27
9
300 gram C
231
27.2
10
700 gram C
320
27
Nilai D1 ( Salinitas Air Bersih)
σ = 111 μS/m
σ = 111 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 111 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.009533 S/m
D1
= ( 5.7 x 0.009533 )1.03
= 0.04979 mg/cm3
Perhitungan Konduktivitas dan salinitas air polutan 50 gram NaCl
σ = 190 μS/m
σ = 190 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 190 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.016318 S/m
D2
= ( 5.7 x 0.016318 )1.03
= 0.08661 mg/cm3
Maka nilai ���� = 1500 �
0.08661 −0.04979
1300
= 0.0424 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi ringan.
Perhitungan Konduktivitas dan salinitas air polutan 200 gram NaCl
σ = 251 μS/m
σ = 251 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 251 x 10-4 ( 1 – 0.020106 ( 27.2 – 20 )
= 0.021458 S/m
D2
= ( 5.7 x 0.021458 )1.03
= 0.11484 mg/cm3
Maka nilai ���� = 1500 �
0.11484 −0.04979
1300
= 0.0750 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi sedang.
Perhitungan Konduktivitas dan salinitas air polutan 550 gram NaCl
σ = 356 μS/m
σ = 356 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 356 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.030575 S/m
D2
= ( 5.7 x 0.030575 )1.03
= 0.165378 mg/cm3
Maka nilai ���� = 1500 �
0.165378 −0.04979
1300
= 0.153 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi berat.
Perhitungan Konduktivitas dan salinitas air polutan 100 gram CaCO3
σ = 170 μS/m
σ = 170 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 170 x 10-4 ( 1 – 0.020106 ( 27.2 – 20 )
= 0.014533 S/m
D2
= ( 5.7 x 0.014533 )1.03
= 0.07687 mg/cm3
Maka nilai ���� = 1500 �
0.07687 −0.04979
1300
= 0.031 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi ringan.
Perhitungan Konduktivitas dan salinitas air polutan 500 gram CaCO3
σ = 226 μS/m
σ = 226 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 226 x 10-4 ( 1 – 0.020106 ( 27.2 – 20 )
= 0.019321 S/m
D2
= ( 5.7 x 0.019321 )1.03
= 0.10307 mg/cm3
Maka nilai ���� = 1500 �
0.10307 − 0.04979
= 0.062 mg/cm
1300
2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi sedang.
Perhitungan Konduktivitas dan salinitas air polutan 900 gram CaCO3
σ = 311 μS/m
σ = 311 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 311 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.02671 S/m
D2
= ( 5.7 x 0.02671 )1.03
= 0.14389 mg/cm3
Maka nilai ���� = 1500 �
0.14389 −0.04979
1300
= 0.1105 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi berat.
Perhitungan Konduktivitas dan salinitas air polutan 180 gram C
σ = 181 μS/m
σ = 181 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 181 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.015545 S/m
D2
= ( 5.7 x 0.015545 )1.03
= 0.08239 mg/cm3
Maka nilai ���� = 1500 �
0.08239 −0.04979
1300
= 0.376 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi ringan.
Perhitungan Konduktivitas dan salinitas air polutan 300 gram C
σ = 231 μS/m
σ = 231 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 231 x 10-4 ( 1 – 0.020106 ( 27.2 – 20 )
= 0.019748 S/m
D2
= ( 5.7 x 0.019748 )1.03
= 0.1054 mg/cm3
Maka nilai ���� = 1500 �
0.1054 −0.04979
1300
= 0.064 mg/cm
2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi sedang.
Perhitungan Konduktivitas dan salinitas air polutan 700 gram C
σ = 320 μS/m
σ = 320 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 320 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.027483 S/m
D2
= ( 5.7 x 0.027483 )1.03
= 0.14818 mg/cm3
Maka nilai ���� = 1500 �
0.14818 −0.04979
1300
= 0.125 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi berat.
HASIL PENGUKURAN SUHU DAN KONDUKTIVITAS
LARUTAN
Tabel A.1 Pengukuran Nilai Konduktivitas dan Suhu Larutan
NO
Larutan yang Diukur
Nilai Konduktivitas (μS/m)
Suhu (˚C)
1
Air
111
27
2
50 gram NaCl
190
27
3
200 gram NaCl
251
27.2
4
550 gram NaCl
356
27
5
100 gram CaCO3
170
27.2
6
500 gram CaCO3
226
27.2
7
900 gram CaCO3
311
27
8
80 gram C
181
27
9
300 gram C
231
27.2
10
700 gram C
320
27
Nilai D1 ( Salinitas Air Bersih)
σ = 111 μS/m
σ = 111 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 111 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.009533 S/m
D1
= ( 5.7 x 0.009533 )1.03
= 0.04979 mg/cm3
Perhitungan Konduktivitas dan salinitas air polutan 50 gram NaCl
σ = 190 μS/m
σ = 190 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 190 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.016318 S/m
D2
= ( 5.7 x 0.016318 )1.03
= 0.08661 mg/cm3
Maka nilai ���� = 1500 �
0.08661 −0.04979
1300
= 0.0424 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi ringan.
Perhitungan Konduktivitas dan salinitas air polutan 200 gram NaCl
σ = 251 μS/m
σ = 251 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 251 x 10-4 ( 1 – 0.020106 ( 27.2 – 20 )
= 0.021458 S/m
D2
= ( 5.7 x 0.021458 )1.03
= 0.11484 mg/cm3
Maka nilai ���� = 1500 �
0.11484 −0.04979
1300
= 0.0750 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi sedang.
Perhitungan Konduktivitas dan salinitas air polutan 550 gram NaCl
σ = 356 μS/m
σ = 356 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 356 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.030575 S/m
D2
= ( 5.7 x 0.030575 )1.03
= 0.165378 mg/cm3
Maka nilai ���� = 1500 �
0.165378 −0.04979
1300
= 0.153 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi berat.
Perhitungan Konduktivitas dan salinitas air polutan 100 gram CaCO3
σ = 170 μS/m
σ = 170 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 170 x 10-4 ( 1 – 0.020106 ( 27.2 – 20 )
= 0.014533 S/m
D2
= ( 5.7 x 0.014533 )1.03
= 0.07687 mg/cm3
Maka nilai ���� = 1500 �
0.07687 −0.04979
1300
= 0.031 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi ringan.
Perhitungan Konduktivitas dan salinitas air polutan 500 gram CaCO3
σ = 226 μS/m
σ = 226 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 226 x 10-4 ( 1 – 0.020106 ( 27.2 – 20 )
= 0.019321 S/m
D2
= ( 5.7 x 0.019321 )1.03
= 0.10307 mg/cm3
Maka nilai ���� = 1500 �
0.10307 − 0.04979
= 0.062 mg/cm
1300
2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi sedang.
Perhitungan Konduktivitas dan salinitas air polutan 900 gram CaCO3
σ = 311 μS/m
σ = 311 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 311 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.02671 S/m
D2
= ( 5.7 x 0.02671 )1.03
= 0.14389 mg/cm3
Maka nilai ���� = 1500 �
0.14389 −0.04979
1300
= 0.1105 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi berat.
Perhitungan Konduktivitas dan salinitas air polutan 180 gram C
σ = 181 μS/m
σ = 181 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 181 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.015545 S/m
D2
= ( 5.7 x 0.015545 )1.03
= 0.08239 mg/cm3
Maka nilai ���� = 1500 �
0.08239 −0.04979
1300
= 0.376 mg/cm2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi ringan.
Perhitungan Konduktivitas dan salinitas air polutan 300 gram C
σ = 231 μS/m
σ = 231 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 231 x 10-4 ( 1 – 0.020106 ( 27.2 – 20 )
= 0.019748 S/m
D2
= ( 5.7 x 0.019748 )1.03
= 0.1054 mg/cm3
Maka nilai ���� = 1500 �
0.1054 −0.04979
1300
= 0.064 mg/cm
2
Dari perhitungan diatas, maka terbukti bahwa isolator terpolusi sedang.
Perhitungan Konduktivitas dan salinitas air polutan 700 gram C
σ = 320 μS/m
σ = 320 x 10-4 S/m
σ(20˚C)
= σ x ( 1 – b( t – 20 )
= 320 x 10-4 ( 1 – 0.020166 ( 27 – 20 )
= 0.027483 S/m
D2
= ( 5.7 x 0.027483 )1.03
= 0.14818 mg/cm3
Maka nilai ���� = 1500 �
0.14818 −0.04979
1300
= 0.125 mg/cm2