Addendum Spek Pengadaan Alkes
KOP PERUSAHAAN
Kegiatan
Pekerjaan
Tahun Anggaran
NO
1
:
:
:
NAMA BARANG
VOLUME
NEBULIZER
TECHNICAL
Features :
a.
Full transparent structure of ultrasonic working parts, beautifully shaped
and in a novel style
b.
Automized fog feeding bellows to be bent freely in any angle, easy in use
by patient
c.
Various protection functions such as automatic water cut protection for
the tank and water level indicating optically
d.
Full plastic enclosure, and closed duct, etc.
Principal technical data :
:
*
Ultrasonic frequency
1.7MHZ ± 10%
:
*
Continuous working time
≥ 4 hours
:
*
Consumed power
≤ 50 VA
:
Maximum capacity of sm
150mL
*
:
*
Maximum capacity of big
350mL
:
*
Maximum atomizing rate
≥4mL/min
:
*
Power supply voltage
~220V, 50Hz
:
*
Timing range
stepless adjustable 0~60min
:
*
Water tank capacity
300mL (observed by water level line)
:
*
Safety Class
Class II, B Type
Page 1
5 Unit
KET
NO
2
3
NAMA BARANG
HEMOGLOBIN METER ELECTRIC
TECHNICAL
1
Measurement range
2
Dilute Ratio
3
Sample Quantity
4
Measurement Time
5
Wavelength
6
Linear
7
Space
8
Accuracy
VOLUME
5 Unit
:
:
:
:
:
:
:
:
9
10
Crossed Contamination
Precision
:
:
11
12
Stability Deviation
Environment Condition
:
:
13
14
Power source
Input power
:
:
0 ~ 200 (g/L)
1 : 251
≤3mL
≤8s
540nm
r≤0.99
no more than 1 g/L
30g/L ~ 100g/L, ±3g/L
101g/L ~ 200g/L, ≤3%
no more than 2%
30g/L ~ 100g/L, SD≤3g/L
101g/L ~ 200g/L, CV≤1.5%
no more than 5g/L
atmospheric pressure 76Kpa ~ 106Kpa
Temperature : 5°C ~ 40°C
relative humidity
Kegiatan
Pekerjaan
Tahun Anggaran
NO
1
:
:
:
NAMA BARANG
VOLUME
NEBULIZER
TECHNICAL
Features :
a.
Full transparent structure of ultrasonic working parts, beautifully shaped
and in a novel style
b.
Automized fog feeding bellows to be bent freely in any angle, easy in use
by patient
c.
Various protection functions such as automatic water cut protection for
the tank and water level indicating optically
d.
Full plastic enclosure, and closed duct, etc.
Principal technical data :
:
*
Ultrasonic frequency
1.7MHZ ± 10%
:
*
Continuous working time
≥ 4 hours
:
*
Consumed power
≤ 50 VA
:
Maximum capacity of sm
150mL
*
:
*
Maximum capacity of big
350mL
:
*
Maximum atomizing rate
≥4mL/min
:
*
Power supply voltage
~220V, 50Hz
:
*
Timing range
stepless adjustable 0~60min
:
*
Water tank capacity
300mL (observed by water level line)
:
*
Safety Class
Class II, B Type
Page 1
5 Unit
KET
NO
2
3
NAMA BARANG
HEMOGLOBIN METER ELECTRIC
TECHNICAL
1
Measurement range
2
Dilute Ratio
3
Sample Quantity
4
Measurement Time
5
Wavelength
6
Linear
7
Space
8
Accuracy
VOLUME
5 Unit
:
:
:
:
:
:
:
:
9
10
Crossed Contamination
Precision
:
:
11
12
Stability Deviation
Environment Condition
:
:
13
14
Power source
Input power
:
:
0 ~ 200 (g/L)
1 : 251
≤3mL
≤8s
540nm
r≤0.99
no more than 1 g/L
30g/L ~ 100g/L, ±3g/L
101g/L ~ 200g/L, ≤3%
no more than 2%
30g/L ~ 100g/L, SD≤3g/L
101g/L ~ 200g/L, CV≤1.5%
no more than 5g/L
atmospheric pressure 76Kpa ~ 106Kpa
Temperature : 5°C ~ 40°C
relative humidity