82
4.2 Menghitung kapasitas daya dukung tiang dari data SPT
Perhitungan kapasitas daya dukung tiang pancang perlapisan dari data SPT memakai metode Meyerhoff dan data diambil pada BH-1
A. Perhitungan pada titik 1 BH-1:
Daya dukung ujung pondasi tiang pada tanah non kohesif adalah :
Q
p
= 40 . N-SPT .
D L
. A
p
400 . N-SPT . A
p
= 40 . 6 .
225 .
1
. 0,0219263 400 . 6 . 0,0219263
= 23,39 kN 52,62 kN
Untuk tahanan geser selimut tiang pada tanah non kohesif adalah: Q
s
= 2 . N-SPT . p . L
i
= 2 . 6. 0,675 . 1 = 8,1 kN
Universitas Sumatera Utara
83 Tabel IV.2 Perhitungan daya dukung tiang berdasarkan data SPT BH-1
Depth Soil
N Cu
α Skin Friction
End Q
ult
Q
ult
Layer kN
Bearing m
kNm
2
Local Cumm
kN kN
ton
0,00
1 _
_ 0,000
0,000 0,000
0,000 0,000
0,50 6
_ _
8,100 8,100
23,388 31,488
3,149 1,00
10 _
_ 13,500 21,600 38,980
60,580 6,058
1,50 13
_ _ 17,550 39,150
50,674 89,824
8,982 2,00
15 _
_ 20,250 59,400 58,470
117,870 11,787
2,50 19
_ _ 25,650 85,050
74,062 159,112
15,911 3,00
2 18
_ _ 24,300 109,350
70,164 179,514
17,951 3,50
17 _
_ 22,950 132,300 66,266
198,566 19,857
4,00 16
_ _ 21,600 153,900
62,368 216,268
21,627 4,50
15 _
_ 20,250 174,150 58,470
232,620 23,262
5,00 16
_ _ 21,600 195,750
62,368 258,118
25,812 5,50
17 _
_ 22,950 218,700 66,266
284,966 28,497
6,00 18
_ _ 24,300 243,000
70,164 313,164
31,316 6,50
19 _
_ 25,650 268,650 74,062
342,712 34,271
7,00 20
_ _ 27,000 295,650
77,960 373,610
37,361 7,50
22 _
_ 29,700 325,350 85,756
411,106 41,111
8,00 25
_ _ 33,750 359,100
97,450 456,550
45,655 8,50
27 _
_ 36,450 395,550 105,246 500,796 50,080
9,00 29
_ _ 39,150 434,700 113,042 547,742
54,774 9,50
30 _
_ 40,500 475,200 116,940 592,140 59,214
10,00 32
_ _ 43,200 518,400 124,736 643,136 64,314
10,50 33
_ _ 44,550 562,950 128,634 691,584 69,158
11,00
3 30
_ _ 40,500 603,450 116,940 720,390 72,039
11,50 28
_ _ 37,800 641,250 109,144 750,394
75,039 12,00
26 _
_ 35,100 676,350 101,348 777,698 77,770
12,50 22
_ _ 29,700 706,050
85,756 791,806
79,181 13,00
26 _
_ 35,100 741,150 101,348 842,498 84,250
Universitas Sumatera Utara
84 Lanjutan tabel IV.2
Depth Soil
N Cu
α Skin Friction
End Q
ult
Q
ult
Layer kN
Bearing m
kNm
2
Local Cumm
kN kN
ton
13,50
4 30
_ _
40,500 781,650
116,940 898,590
89,859 14,00
34 _
_ 45,900
827,550 132,532
960,082 96,008
14,50 38
_ _
51,300 878,850
148,124 1026,974 102,697 15,00
36 _
_ 48,600
927,450 140,328 1067,778 106,778
15,50 31
_ _
41,850 969,300
120,838 1090,138 109,014 16,00
26 _
_ 35,100 1004,400 101,348 1105,748 110,575
16,50 17
_ _
22,950 1027,350 66,266
1093,616 109,362 17,00
5 17
_ _
22,950 1050,300 66,266
1116,566 111,657 17,50
17 _
_ 22,950 1073,250
66,266 1139,516 113,952
18,00 17
_ _
22,950 1096,200 66,266
1162,466 116,247 18,50
18 _
_ 24,300 1120,500
70,164 1190,664 119,066
19,00 20
_ _
27,000 1147,500 77,960
1225,460 122,546 19,50
21 _
_ 28,350 1175,850
81,858 1257,708 125,771
20,00 23
_ _
31,050 1206,900 89,654
1296,554 129,655 20,50
25 _
_ 33,750 1240,650
97,450 1338,100 133,810
21,00 27
_ _
36,450 1277,100 105,246 1382,346 138,235 21,50
29 _
_ 39,150 1316,250 113,042 1429,292 142,929
22,00 30
_ _
40,500 1356,750 116,940 1473,690 147,369 22,50
33 _
_ 44,550 1401,300 128,634 1529,934 152,993
23,00 33
_ _
44,550 1445,850 128,634 1574,484 157,448 23,50
32 _
_ 43,200 1489,050 124,736 1613,786 161,379
24,00 31
_ _
41,850 1530,900 120,838 1651,738 165,174 24,50
30 _
_ 40,500 1571,400 116,940 1688,340 168,834
25,00 34
_ _
45,900 1617,300 132,532 1749,832 174,983 25,50
39 _
_ 52,650 1669,950 152,022 1821,972 182,197
26,00 42
_ _
56,700 1726,650 163,716 1890,366 189,037 26,50
46 _
_ 62,100 1788,750 179,308 1968,058 196,806
27,00 50
_ _
67,500 1856,250 194,900 2051,150 205,115 27,50
54 _
_ 72,900 1929,150 210,492 2139,642 213,964
28,00 6
57 _
_ 76,950 2006,100 222,187 2228,287 222,829
28,50 60
_ _
81,000 2087,100 233,881 2320,981 232,098 29,00
60 _
_ 81,000 2168,100 233,881 2401,981 240,198
29,50 60
_ _
81,000 2249,100 233,881 2482,981 248,298 30,00
60 _
_ 81,000 2330,100 233,881 2563,981 256,398
Universitas Sumatera Utara
85
4.3 Perhitungan kapasitas daya dukung pondasi tiang pada saat penekanan berdasarkan bacaan manometer pada test pemancangan
Kapasitas daya dukung tiang dapat diketahui berdasarkan bacaan manometer yang tersedia pada alat pancang. Kapasitas daya dukung pondasi tiang
dapat dihitung dengan rumus
A P
Q
Keterangan : Q = Daya dukung tiang pada saat pemancangan Ton
P = Bacaan manometer kgcm
2
A = Total luas efektif penampang piston cm
2
Sistem pemancangan pada proyek pembangunan laboratorium akademi keselamatan penerbangan menggunakan hydraulic jack dengan kapasitas 120 ton.
Luas piston A untuk mesin kap. 120 ton = 485,833cm² Working load
= 60 ton P
ult
= 200 x Working load = 200 x 60
= 120 ton Daya dukung berdasarkan bacaan manometer alat hydraulic jack dengan
mesin 120 ton :
Q = P x A = P
x 485,833cm = 485,833P kg
Universitas Sumatera Utara
86 Tabel IV.3 Perhitungan daya dukung tiang berdasarkan bacaan manometer
No Bacaan Manometer kgcm²
Daya Dukung Mesin Kap. 120 ton ton
1 20
18,448 2
40 36,896
3 60
55,344 4
80 73,792
5 100
92,240 6
120 110,688
Tabel IV.4 Perhitungan daya dukung tiang pada saat pemancangan berdasarkan data daily piling record
Pile Cap Kedalaman Pancang
Manometer Mpa
Daya Dukung
P
ijin
Nomor Titik
m ton
ton
C7 - 07 17
12 58,300
29,150 C7 - 08
17 11
53,441 26,721
B1 - 08 17
13 63,158
31,579 B3 - 07
17 12
58,300 29,150
Daya dukung = didapat dari bacaan manometer dikali luas piston P
ijin
= didapat dari nilai daya dukung dibagi 200
Universitas Sumatera Utara
87
4.4. Menghitung daya dukung ultimit tiang dengan menggunakan program Allpile