General Advanced Parameters From the menu shown in Step 11, navigate to Advanced Parameters

CTM; Reviewed: SPOC 6282007 Solution Interoperability Test Lab Application Notes ©2007 Avaya Inc. All Rights Reserved. 42 of 64 AC-MP118-FXO Step Description

12. General Advanced Parameters From the menu shown in Step 11, navigate to Advanced Parameters

General Parameters . Configure the parameters as described below. Select Enable for the Enable Polarity Reversal and Enable Current Disconnect fields. This will allow the MP-118 to provide the proper disconnect indication to various line types if supported by the far-end. The Disconnect Call on Silence Detection field may be set to Yes to allow the MP-118 to disconnect a FXO port if silence is detected for a given period of time. Typically, the POTS trunks connected to the MP-118 FXO ports do not provide a disconnect indication when the far-end hangs up. Depending on the needs of the customer, the Disconnect Call on Silence feature may be required to prevent the FXO ports from being tied up indefinitely when interacting with certain PBX features. See Section 6.2 for more details on this topic. For the purposes of the compliance test, this feature was disabled by setting the Disconnect Call on Silence Detection field to No. If this field is set to Yes, then the Silence Detection Period and the Silence Detection Method fields must also be configured. Care should be taken when selecting the silence detection period so that a call between two users with minimal conversation is not disconnected by mistake. Default values may be retained for all other fields. Scroll down to continue configuring parameters on the lower half of the screen. CTM; Reviewed: SPOC 6282007 Solution Interoperability Test Lab Application Notes ©2007 Avaya Inc. All Rights Reserved. 43 of 64 AC-MP118-FXO Step Description 13. Configure the parameters as described below. In the Max Number of Active Calls field, a value can be entered to define the number of active calls allowed on the gateway up to the maximum supported by the MP-118. The maximum number supported is equal to the maximum number of ports FXS + FXO available on the gateway. The default value of 0 will configure the MP-118 to use the maximum. However, for the compliance test, this field was specifically set to the maximum of 8. Default values may be retained for all other fields. Click Submit. CTM; Reviewed: SPOC 6282007 Solution Interoperability Test Lab Application Notes ©2007 Avaya Inc. All Rights Reserved. 44 of 64 AC-MP118-FXO Step Description

14. Supplementary Services From the menu shown in Step 11, navigate to Advanced Parameters