CTM; Reviewed: SPOC 6282007
Solution Interoperability Test Lab Application Notes ©2007 Avaya Inc. All Rights Reserved.
42 of 64 AC-MP118-FXO
Step Description
12. General Advanced Parameters From the menu shown in Step 11, navigate to Advanced Parameters
General Parameters
. Configure the parameters as described below.
Select Enable for the Enable Polarity Reversal and Enable Current Disconnect
fields. This will allow the MP-118 to provide the proper disconnect indication to various line types if supported by the far-end.
The Disconnect Call on Silence Detection field may be set to Yes to allow the
MP-118 to disconnect a FXO port if silence is detected for a given period of time. Typically, the POTS trunks connected to the MP-118 FXO ports do not
provide a disconnect indication when the far-end hangs up. Depending on the needs of the customer, the Disconnect Call on Silence feature may be required
to prevent the FXO ports from being tied up indefinitely when interacting with certain PBX features. See Section 6.2 for more details on this topic. For the
purposes of the compliance test, this feature was disabled by setting the Disconnect Call on Silence Detection
field to No. If this field is set to Yes, then the Silence Detection Period and the Silence Detection Method fields
must also be configured. Care should be taken when selecting the silence detection period so that a call between two users with minimal conversation is
not disconnected by mistake.
Default values may be retained for all other fields. Scroll down to continue configuring parameters on the lower half of the screen.
CTM; Reviewed: SPOC 6282007
Solution Interoperability Test Lab Application Notes ©2007 Avaya Inc. All Rights Reserved.
43 of 64 AC-MP118-FXO
Step Description
13. Configure the parameters as described below.
In the Max Number of Active Calls field, a value can be entered to define the
number of active calls allowed on the gateway up to the maximum supported by the MP-118. The maximum number supported is equal to the maximum
number of ports FXS + FXO available on the gateway. The default value of 0 will configure the MP-118 to use the maximum. However, for the compliance
test, this field was specifically set to the maximum of 8.
Default values may be retained for all other fields. Click Submit.
CTM; Reviewed: SPOC 6282007
Solution Interoperability Test Lab Application Notes ©2007 Avaya Inc. All Rights Reserved.
44 of 64 AC-MP118-FXO
Step Description
14. Supplementary Services From the menu shown in Step 11, navigate to Advanced Parameters