Perhitungan Volume Tanki-Tanki Lain

GENERAL ARRANGEMENT MT “SAFINA SYUMADHANI” Tanker 3600 BRT TUGAS AKHIR PROGRAM STUDI D III TEKNIK PERKAPALAN PROGRAM DIPLOMA FAKULTAS TEKNIK UNIVERSITAS DIPONEGORO SEMARANG ANDHIKA ADI. S L0G006007 III - 29 = 9,6 x 13,41 x 6,9 = 888,2784 m 3 f. Volume Tangki Muat I Tanki muat I terletak pada frame 136–frame152 dengan jarak 9,6 m. P = 9,6 L = 13,41 T = 6,9 Volume Tangki Muat I = P x L x T = 9,6 x 13,41 x 6,9 = 888,2784 m 3 Volume Tangki Muat total = TM I + TM II + TM III + TM IV + TM V + TM VI = 888,2784 + 888,2784 + 888,2784 + 888,2784 + 888,2784 + 888,2784 = 5329,6704 m 3 Koreksi Volume Muatan Volume Tanki Muat Rencana Volume Muatan Perhitungan Awal 5329,4704 m 3 5306,0091 m 3 = 100 x n Perencanaa Volume n Perhitunga Volume n Perencanaa Volume - = 100 5329,4704 0091 , 5306 4704 , 5329 - = 0,44 0,5 memenuhi

5. Perhitungan Volume Tanki-Tanki Lain

1. PerhitunganVolume Tanki Minyak Lumas Volume Tanki Minyak Lumas Perhitungan tangki minyak pelumasan direncanakan terletak pada Kamar Mesin dengan panjang Tanki Minyak Pelumas p = 2,4 m l = 1,8 m t = 1,2 m GENERAL ARRANGEMENT MT “SAFINA SYUMADHANI” Tanker 3600 BRT TUGAS AKHIR PROGRAM STUDI D III TEKNIK PERKAPALAN PROGRAM DIPLOMA FAKULTAS TEKNIK UNIVERSITAS DIPONEGORO SEMARANG ANDHIKA ADI. S L0G006007 III - 30 Volume Tanki Minyak Lumas = p x l x t = 2,4 x 1,8 x 1,2 = 5,184 m 3. Koreksi Perhitungan Tanki Minyak pelumas : Vol. Tanki Minyak pelumas Vol. Minyak pelumas yang dibutuhkan 5,184 m 3 3,638 m 3 à memenuhi 2. Perhitungan Volume Ruang Pompa Frame Luas FS Hasil 40 106,330 1 106,330 41 107,771 4 431,084 42 109,155 2 218,310 43 110,453 4 441,812 44 111,634 0,5 55,817 45 112,684 2 225,468 46 113,605 0,5 56,803 S 1535,524 Volume = k . h . S = 13 x 0,6 x 1535,524 = 307,1047 m 3 3. Perhitungan Volume air tawar Frame Luas FS Hasil 46 113,605 1 106,330 47 114,403 4 457,612 48 115,089 1 115,089 S 679,031 Volume = k . h . S = 13 x 0,3 x 679,031 = 135,8062 m 3 4. Perhitungan Cofferdam I Buritan Frame Luas FS Hasil 48 115,089 1 115,089 GENERAL ARRANGEMENT MT “SAFINA SYUMADHANI” Tanker 3600 BRT TUGAS AKHIR PROGRAM STUDI D III TEKNIK PERKAPALAN PROGRAM DIPLOMA FAKULTAS TEKNIK UNIVERSITAS DIPONEGORO SEMARANG ANDHIKA ADI. S L0G006007 III - 31 49 115,674 4 462,696 50 116,168 1 116,168 S 693,953 Volume = k . h . S = 13 x 0,6 x 693,953 = 138,790 m 3 5. Perhitungan Tangki Bahan Bakar Frame Luas FS Hasil 50 116,168 1 116,168 51 116,586 4 466,344 52 116,944 1 116,944 S 699,456 Volume = k . h . S = 13 x 0,6 x 699,456 = 139,891 m 3 Volume Tangki Bahan Bakar = 199,672 m 3 6. Perhitungan Volume Slop Tank Frame Luas FS Hasil 52 116,944 1 116,944 53 117,254 4 469,016 54 117,524 1,5 176,286 55 117,762 2 235,524 56 117,973 0,5 58,987 S 1056,757 Volume = k . h . S = 13 x 0,6 x 1056,757 = 211,3513 m 3 Koreksi volume Slop Tank ± 3 dari volume Tangki Muat = 100 x Muat Tangki Volume Tank Slop Volume = 100 0252 , 5597 3513 , 211 x = 3,77 memenuhi GENERAL ARRANGEMENT MT “SAFINA SYUMADHANI” Tanker 3600 BRT TUGAS AKHIR PROGRAM STUDI D III TEKNIK PERKAPALAN PROGRAM DIPLOMA FAKULTAS TEKNIK UNIVERSITAS DIPONEGORO SEMARANG ANDHIKA ADI. S L0G006007 III - 32 7. Perhitungan Cofferdam II Haluan Frame Luas FS Hasil 152 54,324 1 54,324 153 50,353 4 201,412 154 46,369 1 46,369 S 302,105 Volume = k . h . S = 13 x 0,6 x 302,105 = 60,421 m 3 8. Perhitungan Tangki Ballas Ceruk Buritan Frame Luas FS Hasil 1 2,849 1 2,849 2 5,712 4 22,848 3 8,605 2 17,210 4 11,544 4 46,176 5 14,545 2 29,090 6 17,607 4 70,428 7 20,720 2 41,440 8 23,872 4 95,488 9 27,050 1 27,050 S 352,579 Volume = k . h . S = 13 x 0,6 x 352,579 = 70,5158 m 3 9. Volume Tangki Ballas Ceruk Haluan I Frame Luas FS Hasil 154 46,369 1 46,369 155 42,359 4 169,436 156 38,300 2 76,600 157 34,512 4 138,048 158 30,644 2 61,288 159 26,721 4 106,884 160 22,787 2 45,574 161 18,887 4 75,548 162 14,990 2 29,980 163 11,176 4 44,704 164 7,419 2 14,838 GENERAL ARRANGEMENT MT “SAFINA SYUMADHANI” Tanker 3600 BRT TUGAS AKHIR PROGRAM STUDI D III TEKNIK PERKAPALAN PROGRAM DIPLOMA FAKULTAS TEKNIK UNIVERSITAS DIPONEGORO SEMARANG ANDHIKA ADI. S L0G006007 III - 33 165 3,701 4 14,804 FP 0,000 1 0,000 S 824,073 Volume’ = k . h . S = 13 x 0,6 x 824,073 = 164,8146 m 3 Total Volume Tanki Ballas : = V.T.Ballas Ceruk Haluan + V.T.Ballas Ceruk Buritan = 164,8146 + 70,5158 = 235,3304 m 3 Volume Double Bottom = Double Bottom I + Double Bottom II + Double Bottom III + Double Bottom IV + Double Bottom V + Double Bottom VI = 96,8054 + 135,5534 + 144,5632 + 144,966 + 144,9792 + 144,1964 = 811,0636 m 3 Volume Tanki Ballast Total = Vol.Ceruk Haluan Buritan + Vol.Doub.Bottom R. Muat = 235,3304 + 811,0636 = 1046,394 m 3 Berat jenis air laut = 1,025 ton m 3 Berat air ballast = 1046,394 x 1,025 = 1072,554 ton Koreksi berat air terhadap displacement kapal 10 – 17 = 100 x nt Displaceme ballast air Berat = 100 677 , 8197 554 , 1072 x = 13,08 memenuhi

6. Pembagian Ruang Akomodasi