Mesure probe for gas chromatograph, BNC contact 1 Glass jacket Gas separation column 1 Glass tube, straight, l=80 mm, 10pkg. Soap bubble flow meter 1 Rubber caps, pack of 20 1 Lab thermometer,-10..+100C Stopwatch, digital, 1100 s

24. Kühlmantel, GL 258

1 pcs Made of DURAN® glass; GL 258, outer diameter 20 mm, overall length 200 mm. Two hose connections. For use as a condensor jacket fitted over a glass tube or the side arm of a distillation flask.

25. Separating funnel,50ml,GL18 1

pcs

26. Connecting caps,10 pcs, GL18

1 pcs

27. Gasket for GL18, 8mm hole, 10 pcs

1 pcs

28. Teflon sleeve IGJ 19, 10 pcs 1

pcs

29. Clamp f.ground joint,plastic,NS19 2

pcs

30. Control unit gas chromatograph

1 pcs For voltage supply and for equalisation of the measure probe for gas chromatograph • Zero balance: Push button for rough balance, potentiometer for fine balance • Input: BNC sockets for probe • Output: 4-mm sockets for display device e.g. interface • Dimensions mm: 225 × 113 × 125 • Voltage supply: 110...230 VAC

31. Mesure probe for gas chromatograph, BNC contact 1

pcs

32. Glass jacket

1 pcs Glass jacket, cylindrical glass tube with screw closures for different inserts,used as cooling or heating mantle.

33. Gas separation column 1

pcs DURAN®, enables a didactic gas chromatograph to be set up for the low temperature ranges up to 100°C. The gas separation column is suitable to demonstrate the principle of gas chromatography separations at room temperature separating agent: Dinonyl phthalate on kieselguhr; carrier gas: hydrogen or helium. By inserting the gas separation column in the glass jacket, it can be tempered in the range between 10 and 100 °C. With the aid of a measuring probe, a control unit and an interface system or a Yt-recorder the composition of gas or liquid mixtures can be investigated and recorded using a gas chromatograph. Technical data: • Total length of the insert: 310 mm • Length of the separation column spiral shaped: approx. 1.3 m • Outer diameter of the glass cylinder: 36 mm • Length of the connection tube: 55 mm • Outer diameter of the connection tube: 8 mm

34. Glass tube, straight, l=80 mm, 10pkg.

1 pcs exterior Ø 8mm; interior Ø 5 mm.

35. Soap bubble flow meter 1

pcs for the measurement and adjustment of the flow rate of carrier gas during gas chromatography. A glass tube with a scale with rubber caps for taking the soap solution and a right angled tube connection with hose connectors 8mm to be attached to the column. Total length 280mm Outer diameter 12 mm

36. Rubber caps, pack of 20 1

pcs

37. Lab thermometer,-10..+100C

1 pcs enclosed scale thermometer with coloured liquid filling, diameter 8 mm, length 250 mm, bone glass scale, fixed at the upper part by a molten-on glass pin, holding bead or ring, in protective sheath Subdidisions 1°C Immersion depth 50 mm

38. Stopwatch, digital, 1100 s

1 pcs High quality digital stop watch with 7-digit LCD and 2 operation buttons. Start, stop and split are selected by use of a separate button. Battery included: button cell 389 - Start Stop Reset - Addition Split Dual measurement Resolution: 1100 s Maximum range: 9 h 59 min. 59,99 s Dimensions mm: 66 × 70 × 21 Mass: 62 g Battery life time: 1 years

39. Microliter syringe, 10 micro-l