USK PP 04R BAB XII SPEK. TEKNIS

(1)

PEKERJAAN : PENGADAAN MEUBELAIR UNIVERSITAS SYIAH KUALA

PAKET : USK-PP-04

LOKASI : KAMPUS UNSYIAH BANDA ACEH

TAHUN : 2012

Satuan Jumlah

1 Manual centrifuge f. 4 specimens Function and Applications 2 pcs

Manual centrifuge with for 4 specimens. Benefits

To attach to the work bench Combined plastic / metal housing

The gearbox is self lubricating and very smooth with sleeves made of plastic Comes with four centrifuge tubes

Equipment and technical data Speed: 3,000 rpm

Centrifuge tube: contents 15 ml, conical, ungraduated 2 Determining the molecular weight of a polymer

from intrinsic viscosity measurements

Principle 1 set

The viscosity of a liquid is effectively determined by the strength of the intermolecular attractive forces. In the case of solutions, the viscosity of the solvent can alter significantly depending on the type and concentration of the solute. Due to their size, macromolecules have a very considerable impact on the viscosity of the solvent. Viscosity measurements can be used to estimate the mean molecular mass of a macromolecule if something is known about its conformation.

Tasks

1. Use a thermostatted capillary viscometer to measure the viscosities of solutions of polystyrene in toluene over a range of five polymer concentrations.

2. Determine the instrinsic viscosity and from that estimate the molecular weight (relative molecular mass) of the polymer in this solution.

What you can learn about Viscosity of liquids Ostwald capillary viscometer Poiseuilles's equation Macromolecules

Mass average and number average molecular weights The Mark-Houwink equation

Alternative techniques e.g. osmosis Sedimentation (ultracentrifuge methods) Light scattering

BAB XII. SPESIFIKASI TEKNIS

VOL HARGA

(Rp.)

NO NAMA ALAT DESKRIPSI/SPESIFIKASI MERK TYPE NEGARA


(2)

Consist of :

1. Set of Analytical Balance Sartorius CPA 224S 1 pcs

and measure software, 230 V Function and Applications

The balances of the Sartorius CPA series convince already at first sight through an attractive, high-quality design - of the display up to the weighing pan. Onto the second look the "inner values" impress and that amazing price/power ratio. The "mechanical heart" of these balances is the patented monolithic weighing system which guarantees for confident and extremely precise weighing-results and beats in all models of the Sartorius CPA series. That ensures extremely precise weighing-results to your lab at shortest measuring times. Premium balances is also at Sartorius in any case: very best product quality with lasting reliability. All CPA models are equipped with the internal calibrating and adjusting-function isoCAL. When the ambient temperature changes by a specific value or once a defined time interval has elapsed, isoCAL performs internal calibration and adjustment fully automatically. That shows two decisive advantages for your practice: The prescribed, regular calibration and adjusting according to a QM-system is in a fully automatically way guaranteed. The balances works at any time on an unchangeably high accuracy level.

Equipment and technical Data

The analytical balance Competence CPA 224S is equipped with following features: weighing capacity: 220 g

readability: 0.1 mg

four digital filter levels allow the balance to be optimally adapted to the particular ambient conditions at the place of installation built-in, motorized calibration weight; for the highest weighing accuracy at the touch of a key

isoCAL calibration and adjustment function; through regular, fully automatic calibration, this function ensures that the balance's high level of accuracy remains constant

excellent, high-contrast, easy-to-read display, with especially large digits (16.5 mm) very easy to operate; all keys feature positive click action

clear and logically arranged keypad

innovative all-glass draft shield, with smooth-action doors that open extremely wide; ideally designed for thorough cleaning (removable weighing chamber base plate) and amply sized weighing chamber

large weighing pan: for more convenience during weighing weighing pan made of high-grade steel: Ø 80 mm

built-in application programs: counting, weighing in %, net-total formulation; animal weighing; mass unit conversion by toggling between 2 units adjustable feet for a planar placement

dimensions: 213 x 342 x 340 mm

integrated Bi-directional serial interface (RS232) for easy data transmission to PC mechanical overload protection

anti-theft locking device mains supply 230 V~ / 50 Hz Accessories


(3)

classrooms / lecture halls:

Digital large display with RS232, digit height 56 mm (07157-93) Cobra3-Display-Unit, digit height 20 mm (12154-00)

2. Immersion thermostat Alpha A, 230 V 1 pcs

Function and Applications

Immersion circulator with simple,reliable options for obtaining consistent results. Compact unit can be combined with any existing baths up to 25 mm wallthickness. Equipment and technical data

Heater capacity: 1.5 kW Temperature accuracy: ± 0.05 K Working temperature range: 25 to 85°C With additional cooling: -25 to 85°C Power supply: 230 V; 50-60 Hz

Dimensions (WxDxH): 125 x 125 x 300 mm Accessories

Cooling coil (08493-01) Pump set (08493-02)

3. Ubbelohde viscosimeter, 0.4 mm 1 pcs

4. Bath for thermostat, Makrolon 1 pcs

for immersion thermostat, 'safe for upto 10°C continuous use Dimensions: 430 x 140 x 160 mm

5. External circulation set for thermostat Alpha A 1 pcs

The pump set facilitates together with the thermostat Alpha A the

thermostatting of external systems and enlarges thus the field of application ot the thermostat.

The pump set consists of one pump adapter and one reflux adapter with olives to the connection of external devices' at the thermostat.

All necessary mounting hardware are in the scope of delivery contained. Outer diameter of the olives: 12 mm

6. Retort stand, h 750 mm 1 pcs

7. Water jet pump, plastic 1 pcs

8. Nitric acid , 65% 1000 ml 1 pcs

9. Stopwatch, digital, 1/100 s 1 pcs

High quality digital stop watch with 7-digit LCD and 2 operation buttons. Start, stop and split are selected by use of a separate button.

Battery included: button cell 389 - Start / Stop / Reset

- Addition / Split / Dual measurement Resolution: 1/100 s Maximum range: 9 h 59 min. 59,99 s


(4)

Dimensions (mm): 66 × 70 × 21 Mass: 62 g Battery life time: 1 years

10. Water, distilled 5 l 1 pcs

11. Styropor P, 250 g 1 pcs

12. Hydrochloric acid 37 %, 1000 ml 1 pcs

13. Pipette dish 1 pcs

For depositing used pipettes or holding clean pipettes ready for use, plastic, dimensions 220 mm x 300 mm.

14. Acetone, chem.pure 250 ml 1 pcs

15. Pipettor 1 pcs

16. Universal clamp 1 pcs

particularly suited to hold thin pipes and rods; round gripping clamping jaws with cork lining.

Clamping range: 0...80 mm Total length: 230 mm Rod diameter: 10 mm

17. Volumetric flask 250 ml, IGJ14/23 1 pcs

18. Toluene 250 ml 3 pcs

19. Pasteur pipettes, 250 pcs 1 pcs

For single use only; with constriction in the upper part, approx. 2 ml; long drawn out, fine tip; inner diameter at the tip approx. 1 mm; with constriction for cotton wool plug.

20. Weighing dishes, square shape, 84 x 84 x 24 mm, 25 pcs. 1 pcs

Material: impact Polystyrene (PS).Wall thickness approx. 0.2 mm. Light an flat design. Ideal for weighing.

Dimension (LXWXH)/mm: 84 x 84 x 24 Weight approx. 2 g

Pack of 25

21. Rubber tubing,vacuum,i.d.6mm 2 pcs

22. Volumetric flask 100 ml, IGJ12/21 4 pcs

23. Right angle clamp 1 pcs


(5)

25. Graduated cylinder 100 ml 1 pcs

26. Rubber caps, 10 pcs 1 pcs

27. Glass beaker DURAN®, tall, 250 ml 4 pcs

DURAN

28. Volumetric pipette, 20 ml 1 pcs

29. Funnel, glass, top dia. 80 mm 1 pcs

30. Volumetric pipette, 10 ml 1 pcs

31. Volumetric pipette, 5 ml 6 pcs

32. Spoon, special steel 1 pcs

double ended, one end spoon and 'other end spatula,stainless steel polished, length 150mm

33. Wash bottle, plastic, 500 ml 1 pcs

34. Rubber tubing, i.d. 6 mm 4 pcs

or interior pressure of little more than 1 bar; soft rubber, red one meter. Wall thickness 1.5 mm.

35. Hose clip, diam. 8-16 mm, 1 pc. 4 pcs

36. Glass rod,boro 3.3,l=200mm, d=5mm 1 pcs

37. Laboratory Experiments Physics, Chemistry, Biology and 1 pcs

Applied Sciences, CD-ROM, incl. operating manuals 3 Fractional distillation with the bubble tray

column (with the Cobra3 Chem-Unit)

What you can learn about: 1 set

- Bubble tray column - Rectification

- Continuous and discontinuous - distillation

- Gas chromatography Principle and tasks:

In countercurrent distillation (rectification) using a column, the rising va-pour can enter into interactions with the condensate. In this manner, a frac-tional distillation, i.e. a distillation in several steps for the separation of

can be performed in a single apparatus. If bubble tray columns are used conden-sate can be removed from the individual bubble trays. The sump product, the head products and the condensates of both trays are examined and compared gas


(6)

chromatographically. Consist of :

1. Cobra3 Chem-Unit 1 pcs

allows to measure all important measuring quantities in chemistry and biology. You can run the Chem Unit with a computer (via serial interface) or without a computer (combined with the Com-Unit). Inputs:

-pH/Potential 0-14 pH (0.01 pH) -2.2-2.2 V (+/-1mV) 10 Giga-Ohm, BNC

-Conductivity 6 ranges of measure ment 0-1000 mS/cm. pH/Potential and

Conductivity are el ectrically isolated

-Temperature NiCr-Ni-Thermoelem. T1,T2,T3 -100 to +1500 degrC -Temperature Pt1000 sensor T4 -100 to +850 degr.C

-Temperature sensor in housing T0 0 to 85 degr.C. -Analog In 3 ranges of measur. +/-3.2V; 32V; 81V -TTL In/Out for drop counter or motor piston burett General technical data:

-Voltage output 5V / 0.2A e.g. for drop counter -Connections RS232-D-Sub-9 jack

-Bit rate up to 115200 bit/s -Voltage supply 12V / 6W

-shock-resistant plastic housing with support bases, a wide range of fixing possibilities and two lateral connectors for cascading further units

2. Power supply 12V / 2A 1 pcs

Small switching power supply with safetey class 2. Stabilised output voltage and short circuit resistant.

Including power supply cable.Recommended for use with Cobra3. Supply voltage: 100...230 V AC

Supply frequency: 50...60 Hz

3. Data cable, plug/ socket, 9 pole 1 pcs

RS232 data cable with two 9-pin SubD plugs. Cable length: appr. 1.8 m

Mass: 200 g

4. Software Cobra3 Chem-Unit 1 pcs

Measuring software for the Cobra3 CHEM-UNIT from the "measure"-family for data recording, data representation and data analysis:

- software is easy and intuitive to use

- during the measurement you can choose between analogue displays, digital displays and diagrams

- it is possible to activate up to 8 digital dispays plus up to 4 analogue displays plus up to 2 diagrams (each with up to 3 measurment curves) at the same time - manual or automatic data recording (time controled)


(7)

- integrated support for 3 different methods to record titrations manual reagent addition, registration of reagent volume by drop counter, remote control of an automatic motor piston burette - innumerable integrated analysis and display possibilities:

automatic estimation of equivalence point with or without calculation of pKa-values, mean values, integrals and differentials of curves, curve fitting, smoothing of curves, and many more

- export function to any other WINDOWS application - free updates of the software by internet

5. Temp. probe, imm. type, Pt1000, Cobra3 1 pcs

6. Immers. probe NiCr-Ni, teflon, 200°C 3 pcs

NiCr-Ni thermocouples with 2 pin 'standard flat plug Type K, free of thermal tension. Suitable for e.g. 'Digital Thermometer Hand-held measuring device Temperature or interfaces.

Technical data:

Temperature range: - 50…+ 300 °C Response time: approx. 10 s Length of lead: 150 cm Dimensions of the probe Diameter: 7 mm Length: 250 mm

7. Protective sleeves f.temp.probe,2 1 pcs

8. Heating mantle for roundbottom flask, 250 ml, 230 V, 1 pcs

with saftey switch 'Heating mantle for round bottom flasks

with a heating element which is laid out 'for a temperature up to a maximum of 450°C. The heating mantle is built-in 'into a plastic-coated metal case and lined with woven glass fiber cloth 'inside. The case is to the outside

thermally insulated against loss of heat 'and protection-grounded. At the back two tapped holes are made in order to be 'able to attach a tripod (accessories). The current supply occurs via a 1.5 m 'long power cable with earthed plug and a heating zone . A personal security 'adapter which is stipulated to the is enclosed in the scope of delivery. The 'heating mantle has two heating zones and a maximum power consumption of 150 W.

9.Clamp for heating mantle 1 pcs

10. Power regulator 1 pcs

electronic AC power controller for stageless power control of heating devices, ovens, heating mantles, water bathes etc.

Adjustment range: 0, 20 to 75 and 100% Operating Voltage: 230 Volt - 50/60 Hz

Consumer Connection: Schuko power outlet power connector Switching power max. 3450 W ohmsche load


(8)

11. H-base -PASS-, with 5 fixing points 2 pcs H-base for rods 5 to 15 mm diam., '5 clamping positions, weight

approx. 1.4 kg

12. Support rod, stainless steel, 1000 mm 2 pcs

Polished and massive; 'length 1000 mm, diameter 12 mm.

13. Support rod, stainless steel, 750 mm 2 pcs

Polished and massive; 'length 750 mm, diameter 12 mm.

14. Support rod, stainless steel, l = 250 mm, d = 10 mm 1 pcs

Polished and massive; 'length 250 mm, diameter 10 mm.

15. Retort stand, 210 mm × 130 mm, h = 500 mm 1 pcs

16. Right angle clamp 14 pcs

17. Universal clamp 12 pcs

particularly suited to hold thin 'pipes and rods; round gripping clamping jaws with cork lining.

Clamping range: 0...80 mm Total length: 230 mm Rod diameter: 10 mm

18. Bubble tray column, model, with 2 trays 1 pcs

Made of DURAN® glass. For the 'demonstration of fractionating countercurrent distillation. 'The tube of the column has two bubble

trays. The overflow from them flows back 'down inside for a better separation effect. Two upward pointing side arms 'with GL 18/8 threaded connectors for holding thermometers and two 'downward pointing delivery tubes controlled by valve-type taps with 'Teflon spindles. Tube of 12 mm outer diameter at the bottom, GL 25/12 'threaded connector at the top.

19. Round bottom flask, 250 ml, 2-neck, GL25/12, GL18/8 1 pcs

20.Connecting tube,IGJ 19/26-GL25/12 1 pcs

IGJ 19/26 to 12 mm o.d. glass tube.

21.Column head,w. stopcock, NS19 1 pcs

NS19/26 ground glass socket and 'cone to connect to column and 'a condenser Gl18/8 srew cap adaptor to 'insert thermometer

Valve type tap with Teflon 'spindle to remove small 'condensate samples

22. Condenser,Dimroth,IGJ19/26,210mm 1 pcs


(9)

24. Kühlmantel, GL 25/8 1 pcs Made of DURAN® glass; GL 25/8, outer 'diameter 20 mm, overall length 200 mm.

Two hose connections. For use as a con'densor jacket fitted over a glass tube or the side arm of a distillation flask.

25. Separating funnel,50ml,GL18 1 pcs

26. Connecting caps,10 pcs, GL18 1 pcs

27. Gasket for GL18, 8mm hole, 10 pcs 1 pcs

28. Teflon sleeve IGJ 19, 10 pcs 1 pcs

29. Clamp f.ground joint,plastic,NS19 2 pcs

30. Control unit gas chromatograph 1 pcs

For voltage supply and for equalisation 'of the measure probe for gas chromatograph

• Zero balance: Push button for rough 'balance, potentiometer for fine balance • Input: BNC sockets for probe

• Output: 4-mm sockets for display 'device (e.g. interface) • Dimensions (mm): 225 × 113 × 125

• Voltage supply: 110...230 VAC

31. Mesure probe for gas chromatograph, BNC contact 1 pcs

32. Glass jacket 1 pcs

Glass jacket, cylindrical glass 'tube with screw closures for different inserts,used as cooling 'or heating mantle.

33. Gas separation column 1 pcs

DURAN®, enables a didactic gas 'chromatograph to be set up for the low temperature ranges up to 100°C. The 'gas separation column is suitable to demonstrate the principle of gas 'chromatography separations at room temperature (separating agent: Dinonyl 'phthalate on kieselguhr; carrier gas: hydrogen or helium). 'By inserting the gas separation column

in the glass jacket, it can be tempered 'in the range between 10 and 100 °C. With the aid of a measuring probe, a 'control unit and an interface system (or a Yt-recorder) the composition of gas or 'liquid mixtures can be investigated and recorded using a gas chromatograph.

Technical data:

• Total length of the insert: 310 mm • Length of the separation column (spiral shaped): approx. 1.3 m • Outer diameter of the glass cylinder: 36 mm

• Length of the connection tube: 55 mm • Outer diameter of the connection tube:


(10)

8 mm

34. Glass tube, straight, l=80 mm, 10/pkg. 1 pcs

exterior Ø 8mm; interior Ø 5 mm.

35. Soap bubble flow meter 1 pcs

for the measurement and 'adjustment of the flow rate of 'carrier gas during gas 'chromatography. 'A glass tube with a scale with 'rubber caps for taking the soap 'solution and a right angled tube 'connection with hose connectors 8mm to be attached to the 'column. Total length 280mm

Outer diameter 12 mm

36. Rubber caps, pack of 20 1 pcs

37. Lab thermometer,-10..+100C 1 pcs

enclosed scale thermometer 'with coloured liquid filling, diameter 8 mm, length 250 mm, 'bone glass scale, fixed at the

upper part by a molten-on glass 'pin, holding bead or ring, 'in protective sheath Subdidisions 1°C

Immersion depth 50 mm

38. Stopwatch, digital, 1/100 s 1 pcs

High quality digital stop watch 'with 7-digit LCD and 2 operation 'buttons. Start, stop and split are selected 'by use of a separate button.

Battery included: button cell 389 - Start / Stop / Reset

- Addition / Split / Dual measurement Resolution: 1/100 s Maximum range: 9 h 59 min. 59,99 s Dimensions (mm): 66 × 70 × 21 Mass: 62 g Battery life time: 1 years

39. Microliter syringe, 10 micro-l 1 pcs

40. Connecting cord, 32 A, 250 mm, red 1 pcs

42. Connecting cord, 32 A, 250 mm, blue 1 pcs

43. Immersion thermostat Alpha A, 230 V 1 pcs

Features

- Immersion circulator with simple, reliable options for obtaining consistent results

- Compact unit can be combined with any existing baths up to 25 mm wall thickness

- Wide temperature range to meet application needs - Digital settings for simple operation


(11)

- To be used with water as heat transfer liquid - Screw clamp for bath walls up to 25 mm

- Robust design using high grade stainless steel and temperature resistant polymer - Wear-free; integrated overload protection

Technical Data - Heater capacity: 1.5 kW - Temperature accuracy: ± 0.05 K - Working temperature range: 25 to 85°C - With additional cooling: -25 to 85°C - Power supply: 230 V; 50-60 Hz

- Dimensions (WxDxH): 125 x 125 x 300 mm

44. External circulation set for thermostat Alpha A 1 pcs

The pump set facilitates together with

The pump set facilitates together with the thermostat Alpha A the

thermostatting of external systems and enlarges thus the field of application ot the thermostat.

The pump set consists of one pump adapter and one reflux adapter with olives to the connection of external devices' at the thermostat.

All necessary mounting hardware are in the scope of delivery contained. Outer diameter of the olives: 12 mm

45. Bath for thermostat, Makrolon 10 pcs

for immersion thermostat, 'safe for upto 10°C continuous use Dimensions: 430 x 140 x 160 mm

46. Rubber tubing, i.d. 6 mm 2 pcs

or interior pressure of little 'more than 1 bar; soft rubber, red one meter. Wall thickness 1.5 mm.

47. Rubber tubing,vacuum,i.d.6mm 4 pcs

48. Hose clip f.12-20 diameter tube 10 pcs

49. Hose clip, diam. 8-12mm 1 pcs

50. Steel cylinder Helium, 2l, filled 1 pcs

small steel cylinder, 'suitable for set-up on the desk 'valve according to DIN 477 and in compliance with 'pressure gas regulations '(officially approved) purity 99.996% (4.6 ppm) 'content app. 400 l gas

filling pressure 200 bar

colour grey 'pressure reducing valve 'to be ordered separately

51. Table stand f.2 l steel cylinders 1 pcs

52. Reducing valve for CO2 / He 1 pcs


(12)

Round-bott.flask, 500ml,IGJ 29/32

54. Connecting tube,IGJ29/32-GL18/8 1 pcs

55. Teflon sleeve IGJ 29, 10 pcs 1 pcs

56. Stopper,IGJ 29/32,glass,clear 1 pcs

57. Dish, plastic, 150x150x65 mm 1 pcs

58. Water jet pump, plastic 1 pcs

59. Sec.bottle500ml,2xGl18/8,1x25/12 1 pcs

60. Spring manometer, 0...-1000 mbar 1 pcs

61. Stopcock,3-way,t-shaped, glass 1 pcs

62. Glass tube, right-angled 1 pcs

63. Spoon, special steel 1 pcs

double ended, one end spoon and 'other end spatula,stainless steel polished, length 150mm

64. Funnel, glass, top dia. 55 mm 1 pcs

65. Funnel, glass, top dia. 80 mm 1 pcs

66. Graduated cylinder 100 ml 1 pcs

to measure volumes of liquids; 'graduated standing cylinders, glass, calibrated for filling at '+20°C, subdivision 1 ml tall form, with hexagonal base, 'with spout

67. Pasteur pipettes, 250 pcs 1 pcs

For single use only; with constriction 'in the upper part, approx. 2 ml; long drawn out, fine tip; inner diameter at 'the tip approx. 1 mm; with constriction for cotton wool plug.

68. Rubber caps, 10 pcs 1 pcs

69. Snap-cap vials,d=24mm,h=52mm,10p. 2 pcs

70. Glass beaker DURAN®,tall, 150 ml 2 pcs

DURAN

71. Glass beaker DURAN®, tall, 250 ml 1 pcs


(13)

72. Glass rod,boro 3.3,l=200mm, d=5mm 1 pcs

73. Lab. pencil, waterproof 1 pcs

For writing on glass, porcelain or pla'stic surfaces, black.

74. Quartz glass wool 10 g 1 pcs

75. Chromosorb, PAW, 80/100 Mesh, 20 g 1 pcs

76. Boiling chips, 200 g 1 pcs

77. Silicon grease, 100g 1 pcs

78. n-pentane 250 ml 1 pcs

79. n-hexane,puriss. 100 ml 1 pcs

80. n-heptane, extra pure 250 ml 1 pcs

81. Acetone, chem.pure 250 ml 1 pcs

82. Dinonyl phthalate, 100 ml 1 pcs

83. Water, distilled 5 l 2 pcs

84. PC Desktop 1 set

4 Water distiller, 4l/h Function and Application 2 set

Production of distilled water. Equipment and Technical Data Capacity 4 l/h

Low-gas, bacteria and pyrogen free distillate Conductivity approx. 2,5 µS/cm

Thermostatic low water cut-off to protect the heating element

Cooling water requirement approx. 32 l/h Power consumption 3 kW

Dimensions (cm): 28,5 x 51 x 25 Electrical connection: 230 V

5 Calorimetric bomb Function and Applications 1 pcs

Calorimetric bomb for the quantitative determination of combustion heat of liquid and solid organic substances under high oxygen pressure.

Equipment and technical data Stainless steel body contents approx. 120 ml stainless steel lid with valve oxygen filling connection


(14)

max. oxygen pressure 25 bar ignition wire.

6 pH/Potenial meter, Cobra4-Mobile Link, hand-held

Function and Applications 2 pcs

A combination of the Cobra4-Mobile-Link unit with the Cobra4 Chemistry sensor unit containing a pH sensor and 2 x NiCr-Ni thermocouples is ideal for the measurement of pH values, potentials and up to 2 temperatures simultaneously. Equipment and technical data

Temperature:

Measuring range: -200..+1200 °C Resolution: 0.1 K

Measuring accuracy: equal to the accuracy of the gauges used pH:

Measuring range: 0...14 Resolution 0.01K

Measuring accuracy: ± 0,5% Potential:

Measuring range -2000..+2000 mV Resolution: 0.1 mV

Measuring accuracy: ± 0.5% General:

Data flow rate: 5 Hz

Dimensions: approx. 62 mm x 63 mm Weight: 95 g

Power supply: 2 x Mignon rechargeable batteries (AA) Current consumption: < 300 mA

Measurements can be saved on SD memory cards Water resistant case

Dimensions: 210 x 70 x 32 mm approx. Weight: 300 g

7 Set of Analytical Balance Sartorius TE 214S and measure software balances, 230V

Function and applications 2 pcs

Sartorius Talent series precision balances are the alternative for all your simple weighing operations: economically priced yet with an uncompromisingly high degree of quality, reliability and sophisticated weighing technology. Whether you need to operate a balance in the lab, at school or a university, a balance from the Sartorius Talent series will always be the No. 1 choice. The right weighing capacity for every application and every budget? No problem with the Talent series. When it comes to strictly weighing, easy operation is top priority. The balances of the Talent series prove to be particularly talented in this area: just set up the balance, turn it on, and you'll be "on your weigh." It couldn't be any easier than this! The clarity of the display and the "one-key-to-a-function" design of the keypad ensure error-free operation. Equipment and technical data

The analytical balance Talent TE 214S is equipped with following features: weighing capacity: 210 g


(15)

compact design, robust construction, reliable weighing technology all-glass draft shield chamber with smooth-running doors weighing pan made of high-grade steel: Ø 90 mm high-contrast display with large digits

total ease of operation, 2 ergonomically placed tare keys (for left - and right-hander) built-in bidirectional serial interface (RS232)

mains operation for all models of the Talent series, power supply in the scope of delivery integrated application programs: weighing in percent, counting, net-total formulation, dynamic weighing / averaging

mechanical overload protection anti-theft locking device mains supply 230 V~ / 50 Hz Accessories

Digital large displays for the demonstrative indication of the measured values in classrooms / lecture halls:

Digital large display with RS232, digit height 56 mm (07157-93) Cobra3-Display-Unit, digit height 20 mm (12154-00)

8 Set of Precision Balance Sartorius TE 412 and measure software balances,230 V

Function and applications 1 pcs

Sartorius Talent series precision balances are the alternative for all your simple weighing operations: economically priced yet with an uncompromisingly high degree of quality, reliability and sophisticated weighing technology. Whether you need to operate a balance in the lab, at school or a university, a balance from the Sartorius Talent series will always be the No. 1 choice. The right weighing capacity for every application and every budget? No problem with the Talent series. When it comes to strictly weighing, easy operation is top priority. The balances of the Talent series prove to be particularly talented in this area: just set up the balance, turn it on, and you'll be "on your weigh." It couldn't be any easier than this! The clarity of the display and the "one-key-to-a-function" design of the keypad ensure error-free operation

Equipment and technical data

The precision balance Talent TE 412 is equipped with following features: weighing capacity: 410 g

readability: 0.01 g

compact design, robust construction, reliable weighing technology weighing pan made of high-grade steel: Ø 116 mm

high-contrast display with large digits

total ease of operation, 2 ergonomically placed tare keys (for left - and right-hander) built-in bidirectional serial interface (RS232)

mains operation for all models of the Talent series, power supply in the scope of delivery possibly for battery operation

integrated application programs: weighing in percent, counting, net-total formulation, dynamic weighing / averaging


(16)

anti-theft locking device mains supply 230 V~ / 50 Hz Accessories

Digital large displays for the demonstrative indication of the measured values in classrooms / lecture halls:

Digital large display with RS232, digit height 56 mm (07157-93) Cobra3-Display-Unit, digit height 20 mm (12154-00)

9 Magnetic stirrer MR Hei-Standard Function and applications 2 pcs

Modern magnetic hot plate stirrer with a flat and hermetically sealed housing as protection against chemicals:

* separate switchers with LEDs for heating and stirring

* hot plate made of Silumin (aluminium alloys) with ceramic coating: - excellent heat conduction and distribution

'- extremely resistant against scratches and chemicals - plate diameter: 145 mm

* 800 Watt heating power

* hot plate temperature range: 20...300°C * medium temperature range up to 250°C

* extra safety control circuit and hot plate cut-out via two independent temperature sensors

* an independent safety circuit with separate circuit switches off the heating if the nominal hot plate temperature is exceeded by 50°C * connector for electronic temperature control (accessories: contact thermometer)

* medium temperature control accuracy: ±1 K with contact thermometer (accessories)

* temperature accuracy hot plate: ±5 K

* enhanced heavy-duty stirring magnet drives stirring bars with ease * speed range: 100 - 1,400 rpm

* speed accuracy: ±2%

* excellent stirring results in volumes up to 20 litres (water) * electronic current limiting to protect

* supply voltage: 230 V/50-60 Hz * dimension: 173 mm x 277 mm x 94 mm * weight: 2,6 kg

* 3 year warranty 10 UV-VIS SPECTROPHOTOMETER DOUBLE

BEAM

2 unit Hardware

Wavelength range 190 to 1100 nm Spectral bandwidth 1nm (190 to 1100nm). Wavelength display 0.1nm increments.


(17)

Wavelength setting 0.1nm increments (1nm increments when setting scan range). Wavelength accuracy±0.3nm for entire range and ±0.1nm at D2 peak 656.1nm Wavelength repeatability±0.1nm.

Wavelength slew rate About 6000nm/min Wavelength scanning speed 3000 to 2nm/min.

Lamp interchange wavelength Automatic interchange linked to wavelength. The interchange wavelength can be set freely in the range of 295 to 364nm (0.1nm increments).

Stray light Less than 0.02% at 220nm (Nal), Less than 0.02% at 340nm (NaNO2), Less than 1.0% at 198nm (KCl).

Photometric system Double-beam optics.

Photometric range Absorbance: -4 to 4 Abs, Transmittance: 0% to 400%.

Photometric accuracy0.002 Abs at 0.5 Abs, ±0.004 Abs at 1.0 Abs, ±0.006 Abs at 2.0 Abs (measured using NIST930D/NIST1930 or equivalent)

Photometric repeatabilityLess than ±0.001 Abs at 0.5 Abs, Less than ±0.001 Abs at 1 Abs, Less than ±0.003 Abs at 2 Abs.

Baseline stability Less than 0.0003 Abs/Hr (700nm, one hour after light source turned ON). Baseline flatnessLess than ±0.0006 Abs (1100 to 190nm, one hour after light source turned ON).

Noise level Less than 0.00005 Abs (700nm).

Light source 20-W halogen lamp and deuterium lamp built-in light source automatic position adjustment. Monochromator Blazed holographic grating in Czerny-Turner mounting

Detector Silicone photodiode

Software Photometric Mode. Spectrum Mode. Quantitation Mode. Kinetics Mode. Time Scan Mode. Multi-component Quantitation Mode. Biomethod Mode. Maintenance. Shared Functions.

1 set

Computer and Printer

Processor-Intel Core i3-2120, RAM 4GB, Chipset-Intel H61, HDD-500GB, Graphics-Integrated Intel HD Graphics, 2 PS/2, 1 Serial Port Std, Audio-Codec: Realtek ALC656; Jacks: Front HP Out, Mic In; Rear Line-Out, Line-In, Mic-In, OS Windows 7 Professional, Monitor HP LCD 18,50", Laser Jet HP 1102, speed up 17 ppm, 1200 dpi effective output, USB 2 port

1 set

Completed with:

10 mm Absorption Cell Matched pair 1 set

USB interface cable for connecting to PC Stabilizer 3 KVA

11 Fourier Transform –Infra Red Spectrophotometer (FT-IR)

1 unit Hardware

Interferometer Michelson Interferometer (30 degreed incident angle), advanced dynamic alignment system, Sealed and desiccated interferometer with an automatic dryer

Optical system Single beam optics

Beam splitter Germanium-coated KBr plate for Middle IR. Germanium-coated Csl plate for Middle/Far IR. Silicon-coated CaF2 plate for Near IR

Light source Air-cooled ceramic for Middle/Far IR with 3 years guarantee Detector DLATGS detector with Temperature Control for Middle/Far IR Wavenumber range 7,800 ~ 350 cm1

Resolution 0.5cm1, 1cm1, 2cm1, 4cm1, 8cm1, 16cm1 (Middle/Far IR) Optional, 2cm1, 4cm1, 8cm1, 16cm1 (Near IR). Optional

S/N ratio 40,000; 1 and higher, (Peak-to-peak, 4cm-1 resolution, around 2, 100cm-1, 1 minute accumulation)


(18)

Stray light Less than 0.02% at 220nm (Nal), Less than 0.02% at 340nm (NaNO2), Less than 1.0% at 198nm (KCl).

Data Sampling He-Ne laser with 30 months guarantee Gain Control Automatic or manual from x1 – x128

Software

Interface between PC and FTIR IEEE 1394. Hardware Monitoring Self diagnostics, Status monitor. IR Solution, Validation program complies with Japanese Pharmacopoeia/European Pharmacopoeia/ASTM. Data Processing Addition, Multiplication, Abs to % T conversion, Normalization, Baseline correction, Log conversion, Smoothing, Derivative, ATR correction, Kubelka-Munk conversion, Kramers-Kronig analysis, Wavenumber /Wavelength conversion, Peak detection, Peak area calculation. Quantitative processing Multipoint calibration curve with peak height/area/ratio, Multilinear regression (MLR method). Spectrum search parameters, Search, Library creation. Display High wavenumber compression, Zooming, Auto scaling, Overlay, Shift display. Edit Cut, Copy, Paste. Audit Trail Container function with stored interferogram/background spectrum, operation history. Password Protection. Log recording. FDA CFR Part 11 compliance, Electric Signature Accessory Detection Automatically recognize installed accessory. Then sets up scan parameters and runs macro program.

Computer and Printer 1 set

Processor-Intel Core i3-2120, RAM 4GB, Chipset-Intel H61, HDD-500GB, Graphics-Integrated Intel HD Graphics, 2 PS/2, 1 Serial Port Std, Audio-Codec: Realtek ALC656; Jacks: Front HP Complete with :

IEEE1394 Connection kit for desktop PC 1 set

DRS-8000A Diffuse Reflectance Attachment 1 set

ATR-8200HA Attenuated Total Reflection Attachment Horizontal Type 1 set

KBr Crystal (100g) 1 set

Agate Mortar and Pestle 1 set

Demountable Cell, KBr 1 set

Fixed Thickness Cell, KBr 0.5 mm 1 set

Stabilizer 5 KVA 1 set

Monomer and Polymer Library Evacuable Die for KBr Pellets Hydraulic Press for KBr Die Demudifier

12 PCR Thermal Cycler with Thermal Gradient 1 set

A thermal cycler with six separate peltier blocks provide maximal versatility and flexibility . Dimension :

W x D x H : 23.7 cm x 48.5 cm x 24.5 cm Weight : 10.6 kg

Specification :

- Sample throughput : 96 x 0.2 mL - PCR volume range : 10- 80 uL - Block format : 0.2 mL proprietary Alloy

- Heating and cooling system : six separate peltier blocks - Temperature zone : 6 (six)

- Veriflex blocks : 25 oC (5 oC zone to zone)

- six separate peltier blocks provide a better than gradient approach to PCR optimization. - six peltier blocks can be used to run up to six different annealing temperature in the same run.


(19)

- Max. Block ramp rate : 3.90 oC/sec - Max. Sample ramp rate : 3.35 oC/sec - Enabled to run fast chemistry - Temperature accuracy : ± 0.25 oC - Temperature range : 4.0 oC to 99.9 oC - Temperature uniformity : < 0.5 oC

- Display Interface : 16.51 cm VGA 32k color with touch 'screen - Tm Calculator : Menu driven through touch screen

- Instrument memory : 800 protocols on board, unlimited 'with use of USB memory stick - VeritiLink allows the Veriti system to be connected in a 'satellite format

- Protocol transfer from one Veriti to another can be done using USB memory stick

Includes :

- PCR tubes 0.2 mL (1000 pcs)

- AmpliTaq Gold 360 Master Mix (500 reactions) - one year warranty

13 Horizontal Electrophoresis Mini Gel Electrophoresis Systems 1 set

- Gel Size : 9 x 11 cm

- Foot print (W x L x H): 15 x 22 x 9.5 cm - Running buffer volume : 600 mL - Run 5 to 34 samples

• Offers a wide range of combs

• Two comb slots on gel tray double sample capacity by doubling number of sample wells

• UVT gel trays are silk screened with a fluorescent ruler for easy measurement of bands

- Complete System Includes: • Buffer Chamber

• SuperSafe Lid with Attached Power Supply Leads • EasyCast Gasketed U.V. Transmissible (UVT) Gel Tray • 2 Combs: 10 & 14 Well, Double Sided, 1.0/1.5 mm Thick Includes :

• Thermo Scientific EC200XL High Current Power Supply Simple-to-use, multi-purpose, lightweight and great for DNA / RNA, Protein and Blotting electrophoresis. With Specification

- Max. Voltage : 200 V - Max. Current : 2 A - Max. Power : 200 W - 220V compatible - 4 (four) output terminal

- Power-off memory retains settings after shutdown - Stackable design saves benchtop space - Soft-touch key pad allows quick set-up - Easy to operate


(20)

- Non-skid rubber feet provide stability

14 Gel Documentation System 1 set

Integrated Tablet Computer, includes darkroom, Dual Wavelength UV Transilluminator, EPI and Trans White Light Illumination,Illumination EPI Blue Light , CCD Camera, cables image Lab software

Automation Capabilities :

SmartCapture Technology : Automatically capture the best image without the need to hassle with hardware or software 6 Megapixel CCD Camera : Highest resolution available for a gel documentation system

16 bit depth, deeply cooled : Low noise, wide dynamic range for quantitative accuracy in chemiluminescent applications Integrated Tablet Computer : No additional computer cost

6 Position Motorized Filter Wheel : For ultimate flexybility in dye selection EPI Blue Light Illumination : Compatible with SYBR® Safe Dye Chemistry EPI and Trans White Light Illumination : For visible dyes

Dual Wavelength UV Transilluminator : 302 and 365nm with variable intensity Camera :

• 6MP for high resolution images

• Regulated cooling 40ºC below ambient for chemiluminescence imaging • USB connection for fast downloads

• Fast refresh rate for live imaging

• High quality images ideal for downstream analysis Field of View : 25 cm X 18.5 cm

Cabinet :

• 365/302 nm pull out UV transilluminator • EPI white lights

• EPI blue LEDs

Filter Wheel : 6 Positions, motorized Filters : Orange Filter (590 nm)

Applications : Chemiluminescent Western blots, fluorescent and visible gels, and SYBR® Safe dye imaging

Certifications : CE, CSA

Product Footprint : 12.5” wide by 18” deep / 31.75cm wide by 45.72 cm deep Computer Requirements : Tablet Standard. Options for desktop available. INCLUDES:

PC + PRINTER Paper Roll

15 Vertical Electrophoresis 1 set

Gel size : 10 x 8-10 cm * Foot print : 13 × 17 × 14 cm * Vertical system: Double-sided

* Lower buffer volume: 150 mL, Upper buffer volume: 150 ml Complete System Includes:

• Upper Buffer Chamber with Internal Cooling Core • Lower Buffer Chamber


(21)

• SuperSafe Lid with Attached Power Supply Leads • 4 Blank Glass Plates

• 2 Notched Glass Plates • 2 Notched Alumina Plates • Spacer Set: 0.8 mm Thick

• Blocking Plate for Single Gel Operation • Spacer Placer

• 2 Combs: 10 Well, 0.8 mm Thick

Includes : Thermo Scientific EC200XL High Current Power Supply

Simple-to-use, multi-purpose, lightweight and great for DNA / RNA, Protein and Blotting electrophoresis.

With Specification - Max. Voltage : 200 V - Max. Current : 2 A - Max. Power : 200 W - 220V compatible - 4 (four) output terminal

- Power-off memory retains settings after shutdown - Stackable design saves benchtop space - Soft-touch key pad allows quick set-up - Easy to operate

- Designed for safety

- Non-skid rubber feet provide stability 16 Displacenet Transducer

Capacity: Rated output: Sensitivity: Non-linearity: Spring force: Frequency response: Temperature effect on zero: Compensated temperature range: Temperature range: Input/output resistance: Recommended exciting voltage: Allowable exciting voltage: Holders supplied: Weight:

10mm

5mV/V±0.1% (10000×10-6 strain±0.1%) 1000×10-6

strain/mm 0.1%RO

3.4N 12Hz 0.01%RO/

℃ 0~+40

(no condensation -10~+60

(no condensation 350Ω

Less than 2V 10V 1 pc. 90g


(22)

Capacity: Rated output: Sensitivity: Non-linearity: Spring force: Frequency response: Temperature effect on zero: Compensated temperature range: Temperature range: Input/output resistance: Recommended exciting voltage: Allowable exciting voltage: Holders supplied: Weight:

25mm

6.25mV/V±0.1%(12500×10-6 strain±0.1%) 500×10-6 strain/mm 0.1%RO 3.4N 8Hz 0.008%RO/ ℃ 0~+40 ℃ (no condensation -10~+60 ℃ (no condensation 350Ω

Less than 2V 10V 1 pc. 100g 3 Unit Capacity: Rated output: Sensitivity: Non-linearity: Spring force: Frequency response: Temperature effect on zero: Compensated temperature range: Temperature range: Input/output resistance: Recommended exciting voltage: Allowable exciting voltage: Holders supplied: Weight:

50mm

5mV/V±0.1% (10000×10-6 strain±0.1%) 200×10-6 strain/mm

0.1%RO 3.4N 6Hz 0.01%RO/

℃ 0~+40

(no condensation

-10~+60

(no condensation 350Ω

Less than 2V 10V 2 pcs. 270g 3 Unit Capacity: Rated output: Sensitivity: Non-linearity: Spring force: Frequency response: Temperature effect on zero: Compensated temperature range: Temperature range: Input/output resistance: Recommended exciting voltage: Allowable exciting voltage: Holders supplied: Weight:

100mm

5mV/V±0.1% (10000×10-6 strain±0.1%) 100×10-6 strain/mm 0.1%RO 4.9N 3Hz 0.01%RO/ ℃ 0~+40 ℃ (no condensation -10~+60 ℃ (no condensation 350Ω

Less than 2V 10V 2 pcs. 580g

3 Unit


(23)

Gauge length (Span) 50mm Capacity ±2mm

Rated output 2mV/V4000×10-6 strain) Sensitivity 2000×10-6

strain/mm Non-linearity 0.5%RO

Temperature range 0~+40 ℃ Input/output resistance 350Ω

Recommended exciting voltage Less than 2V Allowable exciting voltage 10V

3 Unit

Gauge length (Span) 100mm Capacity ±2mm

Rated output 2mV/V4000×10-6 strain) Sensitivity 2000×10-6 strain/mm Non-linearity 0.5%RO

Temperature range 0~+40 ℃ Input/output resistance 350Ω

Recommended exciting voltage Less than 2V Allowable exciting voltage 10V

3 Unit

18 Displacenet Transducer Capacity: 1000mm

Rated output: 5mV/V (10000×10-6 strain)±0.3%

Sensitivity ( ×10-6 strain/mm): 10 Non-linearity: 0.3%RO

Temperature range: -10 ~ +80°C (no condensation)

2 Unit

19Compressometer The CM compressometer is designed to conduct a strength test. It measures the axial strain on a cylindrical concrete specimen placed in and secured by screws to the inner chamber of this compressometer. It uses a high-sensitivity strain gauge to measure the amount of strain. By multiplying a measurement by a certain factor, the amount of strain can be calculated as a numerical value. Unlike the case of ordinary strain gauges, this compressometer is simple and easy to operate and can be used repeatedly. However, it cannot be used to conduct breaking tests

Applicable specimen ø10×20cm Gauge length 100mm Capacity 50000×10-6

strain

2 Unit

20 Data Logger 2 Unit

Number of channels 1000 in combination use with switching box Measuring object Strain, DC voltage, Thermocouple

temperature Pt RTD temperature

Scanning time Fastest 0.4 sec./1000 channels in combination use with high speed switching box IHW-50G

Dimension 320(W)×130(H)×440(D)mm Weight 8kg


(24)

21 Multi - Chanel Digital Strain Meter 1 Unit Number of channels 30 channels

Measuring object Strain, Voltage Measuring range ±20000×10-6strain Frequency response DC~3kHz (-3dB±1dB) Dimension 380(W)×148(H)×486(D)mm Weight 12 kg

Power supply AC90-250V 50/60Hz 80VA max. DC10-30V 3.5A max

c/w . : - Software DRA – 730 AS - Software DRA – 730 AD

22 Bridge Box 1 Unit

Number of channels

10 channel ,

Input Ordinary

2-wire quarter (short between B and C), 3-wire quarter 120Ω Half and full bridge 60 ~

1000Ω

Input Post-yield

2-wire quarter (short between B and C), 3-wire quarter 120Ω Half and full bridge 60 ~

1000Ω

Connection Screwing, soldering

Dimensions

255*(W) × 100(D) × 35(H)mm (10-channel type, expect projecting part, *Smaller by

50mm every 2-channel reduction

Weight 1.4 kg* (10-channel type) *lighter by 0.2 kg every 2-channel reduction

Option

Cable : CR-612

23 Displacement Transducer

Capacity Rated output Sensitivity Non-linearity Temperature range Input/output resistance Recommended exciting voltage Allowable exciting voltage Weight

5 (2~7)mm

2.5mV/V 5000×10-6 strain) 1000×10-6 strain/mm 1%RO

0~+ 40 ℃ 350Ω Less than 2V 10V 42g 1 Unit Capacity Rated output Sensitivity Non-linearity Temperature range Input/output resistance Recommended exciting voltage Allowable exciting voltage Weight

5 (3~8)mm

2.5mV/V 5000×10-6 strain) 1000×10-6 strain/mm 1%RO 0~+40 ℃ 350Ω Less than 2V 10V 42g

1 Unit


(25)

Capacity Gauge Length Applicable test specimen Rated output Sensitivity Non-linearity Temperature range Input/output resistance Recommended exciting voltage Allowable exciting voltage Weight

5mm 50mm

Round bar φ 8 ~20mm 3mV/V 6000×10-6 strain) 1200×10-6 strain/mm 0.3%RO

0~+40 ℃ 350Ω Less than 2V 10V

30g (Extensometer) / 40g (1 pair of holder)

25 Displacement Transducer 1 Unit

Capacity 500mm

Rated Output 5mV/V (10000×10-6 strain) ±0.3% Sensitivity 20×10-6

strain/mm Non-linearity 0.3%RO Spring force 1.5N

Temperature range -10~+80 ℃

(no condensation) Input/output resistance Input 206Ω Output 350Ω Recommended exciting voltage Less than 2V Allowable exciting voltage 10V

Weight 210g

26 Acceleration Transducer 1 Unit

Capacity 100m/s2

Rated Output 0.5mV/V 1000×10-6 strain Non-linearity 1%RO

Frequency response 300Hz Natural frequency 500Hz Cross sensitivity 3%RO Temperature range -10~+50

℃ Over load 300%

Input/output resistance 1kΩ

Recommended exciting voltage Less than 5V Allowable exciting voltage 15V

Weight: 13g


(26)

Capacity 100m/s2

Rated Output 0.5mV/V 1000×10-6 strain Non-linearity 1%RO

Frequency response 300Hz Natural frequency 500Hz Cross sensitivity 3%RO Temperature range -10~+50

℃ Over load 300%

Input/output resistance 1kΩ

Recommended exciting voltage Less than 5V Allowable exciting voltage 15V

Weight: 25g

28 Impact Test

1

Set

Range of application

• Impact and impact bending tests on metals (Charpy, Izod – not instrumented) • Brugger-Method tests to ensure the wear characteristics of toothed gear wheels • Wedge-impact test to determine the strength characteristics of structural adhesives General Specification

Pendulum Impact Tester With analog and digital display for use with or without PC (USB upstream interface)

Basic machine-frame for pendulums up to 450 J

Incl. complete protective cage acc. to EN 954-1, category 3 - Incl. TÜV-certified protective interlock circuit

Incl. motorized pendulum lifting Incl. electro-magnetic pendulum release

with electro-magnetic pendulum release and motorized pendulum return electrically monitored protection units and protection housing

The design of the protection housing facilitates easy handling during the testing process, changing tools, pendulums or fixtures, re-configuring different test types and maintenance and calibration.

Operating components are centralized and illuminated to show the machine status and error messages Front door, side doors and specimen removal slot allow:

• Simple placement of the specimen • Quick changing of the vise and the pendulum

• Easy access during maintenance, inspection and calibration • Easy removal of specimen remains

Test results: Impact Energy (%), Impact Energy (J), Impact Strength (N/m²).

Output Units: Digital Display of the device electronics and Analog round display, PC (TestXpert software). Check functions: Friction corrections, vertical position of pendulum, time of swing, display of instrument's data Correction Functions: Air and Bearing friction, Kinetic yoke energy (Impact tensile tests).

Impact velocity : 5.23 m/s Impulse resolution : 0.036

Technical data for the basic instruments


(27)

Electrical connections 3 x 400 V, 50 Hz, 0.5 kW Dimensions: (height x width x depth) 2450 x 1400 x 500 mm

Weight without foundation approx. 700 kg

Impact velocity 5.23 m/s

Corresponds to following safety requirements ISO 12100-1, EN 60204-1, EN 1050, EN 954-1, DIN 51233

Test standards : ISO 148-1, ISO 148-2, EN 10045, DIN 50115, ASTM E 23, EN 2003-2, BS 131-1, ZF 15-53, ISO 11343, JIS B 7722

Supply Included :

Reinforcement for foundation for Zwick Pendulum Impact Tester

Universal vise - Support and abutment clamp for running tests to Charpy, IZOD or impact tensile tests Pendulum rod for pendulum heads 300 J and 450 J

Pendulum hammer, 450 Joule - For the determination of dynamic resistance to cleavage according to DIN EN ISO 11343 - With hardened tup

Pendulum head 450 J for pendulum rod - For bolt-on, noninstrumented and instrumented Charpy-, Izod- and Tensile Impact fins - For bolt-on, instrumented Brugger fin

Series transformer - For 3 phases mains connection 380 V, 50/60 Hz - For connection of a pendulum impact tester RKP 450 or PSW 750 - With accessories and for lowering the residual current

Fin according to ISO 148-1 - Made of tool steel, hardness HRC 60 ± 1 - Not instrumented, exchangable - For testing of specimen made of non- or low-alloyed steel - Remark: more significant fins are available for high-alloyed steel or a higher quantity

Fin according to ASTM E 23 - Made of tool steel, hardness HRC 60 ± 1 - Not instrumented, exchangable - For testing of specimen made of non- or low-alloyed steel - Remark: more significant fins are available for high-alloyed steel or a higher quantity

Centring specimen holder - For Charpy specimen (U or V notch)

Support for specimen DIN 50115 DVMF (1975) - Dimensions: 55 x 8 x 10 mm Set contains 2 pieces supports

Support for specimen ISO 148-1/ASTM E 23 - Dimensions: 55 x 5 x 10 mm - Set containing 2 pieces supports

Abutments - High-speed steel, hardness HRC 62 ± 1 - For specimen to ISO 148-1, ASTM E 23, DIN 50115 DVM & DVMF - For testing of specimen made of low-alloyed steel

Supports for specimen - To ISO 148-1, ASTM E 23, DIN 50115 DVM & DVMF - Specimen dimensions 55 x 10 x 10 mm - HRC 62 ± 1

Abutments - Made of powder-metallurgical steel (PM), hardness HRC 65 ± 1 - For specimen to ISO 148-1, ASTM E 23, DIN 50115 DVM & DVMF - For testing of specimen made of high-alloyed steel Centring specimen holder at the side - For Charpy specimen - Mounted to the right side of the vise, as seen in impact direction

Interchangeable Izod tup


(28)

Clamping device for Izod specimens 10 mm x 5 mm Clamping device for Izod specimens 10 mm x 10 mm

29 Vickers Hardness Tester

1

Set

Range of application

• Can be used for all hardness test methods that evaluate via optical measurement of the indentation: - Vickers hardness according to DIN EN ISO 6507

- Knoop hardness according to ASTM E 9385 - Brinell hardness according to DIN EN ISO 6506 - case hardening, hardening and nitride hardening depth, - as well as the scratch hardness (analogue version)

• Low-load range from HV0.2 to HV10 are achieved via dead weight application

Measurement method analogue

Test data evaluation manual

Loading assembly with direct mass (weight) loading

Test table’s support surface 300 x 230 mm

Test height 0 ... 300 mm 0 ... 300 mm

Throat 135 mm 135 mm

Test load stages (0,294 / 0,49 / 0,98 / 1,47) / 1,96 / 2,94 / 4,9 / 9,8 / 19,6 / 29,4 / 49 / 98 / (196 / 294) N

Indentation time 0 ... 10 sec 0 ... 10 sec

Optical indentation measurement device Microscope with monocular (bright field illumination system)

Electrical connections 110/220 V A.C.

Dimensions (height x width x depth) 600 x 400 x 350 mm

Mass (weight) approx. 50 kg nett / 90 kg gross

Supply Included :

Vickers hardness tester, - Analogue version - For manual evaluation - Load stages: HV 0,2 ... HV 10 - Manual load change

Vickers pyramid indentor 136° - With official test certificate

Manual x-y table - Table size: 135 x 135 mm - Fmax: 500 N - Movement: 25 x 25 mm - With micrometer screws - With digital display - And position transfer via RS232

Objective lenses for 50 times - Magnification Objective lenses for 100 times - Magnification Objective lenses for 200 times - Magnification Objective lenses for 400 times - Magnification Objective lenses for 600 times - Magnification Monocular

Device for tests in the macro range - Test load stages: 196/294 N Whetstone

Adapter plate for x-y table for - Hardness tester (tc-zwicki, ZHV10) - Incl. quick connector Tool Mount

Round Specimen mount Sheet metal clamps


(29)

Flat specimen mount

Parallel vice - Pairs of clamping vice required - Mounting on tslots possible Pair of clamping jaws for parallel vice - For flat specimen up to 80 mm thickness Pair of clamping jaws for parallel vice - For round specimen dia. 4...14 mm Pair of clamping jaws for parallel vice - For round specimen dia. 14...40 mm Pair of clamping jaws for parallel vice - For round specimen dia. 40...70 mm Quick-action vise

Ball and socket joint Support

Prismatic mount - For specimen dia. 1 ...20 mm Prismatic mount - For specimen dia. 5 ...70 mm Prismatic mount - For specimen dia. 30 ...150 mm

Rubber-Air-Dampers for ZHV10 to minimize - External vibration influences (to be attached to the machines socket)

Electrical connections for illuminator 220 V, - 50/60 Hz

Impinging coaxial light with LED for - Zwick hardness measuring microscopes LED ring lamp for Zwick hardness - Measuring microscopes

Power supply with current control, for - Impinging coaxial light and LED ring lamp, 220V

30 Rockwell hardness tester

1

Set

Test method Rockwell

Load Pre-load 10 kgf

Test load 60, 100, 150 kgf

Pre-load setting with optical and acustic support

Load control automatic load application, holding, and removal

Load application via spring force

Starting test action automatically or manually

Holding time 1 - 50 sec

Data calculation average value R calculation

Scales ABCDEFGHKLMPRSV

Output signal RS232

Max height of specimen 250 mm

Max depth of specimen 150 mm

Dimensions (h x w x d) 782 x 292 x 700 mm

Nett weight approx. 90 kg

Power supply 120 or 240 (50 - 60 Hz)

Standard accessories 1 Diamond indentor 120° 1 Ball indentor 1/16“ 10 Spare balls 1/16“ 1 Support table dia. 70 mm

1 Support table dia. 6 mm with prism for max dia. 30 mm 1 HRB hardness comparison plate


(30)

31 Portable hardness tester

1

Set

Measurement range (dependent upon the material

group(s) e. g. for low alloyed steel)

150 - 1000 HL (Leeb) 75 - 1000 HV (Vickers) 75 - 700 HB (Brinell) 35 - 100 HRB (Rockwell B) 20 - 70 HRC (Rockwell C) 30 - 100 HS (Shore)

250 - 2200 N/mm2 (Tensile strenght)

Weight 200 g

Dimensions (diameter x length) 38 x 170 mm

Temperature range Operation: - 10 ... + 50 °C

Storage: - 20 ... + 70 °C

Test method Rebound hardness measurement to ASTM A 956, dynamic measurement method: quotient from rebound (Rp)- and impact Ap) speed with output of the hardness in Leeb HL = 1000 Rp/Ap

Setup Miniaturised, processor controlled rebound hardness tester, impact device with integrated electronics, impact energy approx. 12 N/mm2, ball dia. 3 mm (Wolfram carbide ball)

Material that can be tested Forged, rolled and cast materials

Saved material groups Low/Non-alloyed steel and steel casting, tool steel, stainless steel,

cast iron, spheroidal iron, aluminium cast alloys, brass, bronze, and copper wrought alloys Display statistics, automatic device shut down,

keypad

LCD, 4-digit display of the hardness value and status symbols, average value display, automatic shut down after 3 minutes of no-use in the average value mode, low battery display, device shut down at undervoltage, soft touch keypad with 2 buttons

Conversion scales and resolution HL (1.0), HV (1.0), HB (1.0), HS (0.1), HRC (0.1), HRB (0.1), N/mm2 (5.0)

Conversion To DIN 50150, ASTM E 140, device specific (Dyna)

Current supply and duration of operation Battery operation (2x MICRO AAA batteries, NiCd, NiMH or AIMn), > 4000 measurements (dependent upon the battery operation)

32 Coordinate Measuring Machine

1

Set

Measuring Range : X = 700mm, Y = 700mm, Z = 600mm Length-measuring error as per ISO 10360-2 :

MPE_E = 1.8 + L/300 µm, MPE_P = 1.8 µm with VAST XXT Temperature range in which the specification is guaranteed : 18-22ºC Machine Characteristics and Features :

Open bridge design on ceramic guideways Integrated passive vibration damping C-99 controller

Reference probe Software basic package Acceptance documents, manual

Standard Control Panel


(31)

Calibration sphere, diameter = 30 mm RDS Prep Kit

Probe Sensor System RDS-CAA/VAST XXT TL3

RDS-CAA select indexing probe holder

VAST XXT TL3 Scanning Probe (including 2 stylus adapter plates) RDS/VAST XXT adapter plate

Stylus Kit 1 (Short) for VAST XXT, M3 Stylus carbide, ruby, 1.5 x 30 Stylus TF, ruby, 3.0 x 33 Stylus TF, ruby, 3.0 x 50 Stylus TF, ruby, 5.0 x 50 Stylus TF, ruby, 5.0 x 75 Hook wrench DG5 Pin wrench 1.2 Computer System

Entry Computer System for CALYPSO HP Z400 Workstation 32/64 Bit G2 with the following specification: MS Windows 7 64 Bit

Intel Xeon W3520 2.66 8MB/1066 QC CPU HP 6 GB (3x2GB) DDR3-1333 ECC RAM NVIDIA Quadro FX1800 768MB Graphics 1 x HP 160GB SATA 10K SFF 1st 1 x HP 1 TB SATA 7.2K 2nd

HP 16X DVD+-RW SuperMulti SATA 1st Drive 19" LCD Monitor

Laserjet Printer Software System

Basic CALYPSO CNC Geometry licence

Full-features graphic measurement and evaluation software with CAD core for all prismatic measurements

Easy to use due to procedure being based on inspection schedule Full graphic support including visualization of tasks and input data Few key operations and low susceptibility to errors due to

automatic element identification and automatic travel route generation Measuring time optimazation due to variable inspection scope (FOCUS)


(32)

Variable presentation of results with simple integration of part-related graphics

Multimedia support for documenting the parts clamping and probe configuration for the CNC start

CAD-Interface STEP Converter USB Dongle Hardlock for CALYPSO Special Accessories

Refrigerated Air Dryer

Uninterruptible Power Supply (UPS) - 2kVA

33 CNC SIMULASI

11

License

MTS CNC Simulation Training System Ver 7.0 Simulation For Turning & Milling Process System Performance Characteristics

CONFIGURATION

The simulation system is an open system qualities, free configure in ANY system machine structure, CNC controllers in order to adapt the simulation system or simulator into different machine tools and controls system for training.

A comprehensive configuration program serves to adapt the system modules to given operation conditions as below :

Machine Tools

Free Configure into different dimension of the machining area

Free Configure into the traverse range of tool carriage, reference points, spindles, tool changer, different type of turret, magazine, tailstock and clamping device

Stationary and mobile components of the working area can be selected and configured in machine simulation

Number of tools in turret or magazine could free be able configured to maximum of 99 different tools Work Fixture

The work fixtures from lathe simulation system consist of spindle, chucks and jaws, collet and soft jaws. Chucking between centers is also possible.

Tailstock and centre sleeve are automatically adapted to geometric dimensions machine.

The milling simulation system consists of free configuration on machine worktable, vice, modular clamps and magnetic table.

It could be able to position or free moving the clamps and work part on pre-defined machine worktable and working range


(33)

Tools Systems

The tools systems consist of the support different cutting tools and tools holders

Each individual cutting tools with cutting tips could be free configured on shape of cutting tip, cutting angle (rake and clearance angle), in feed angle and adapt with different tools holder or arbor standard Each single tools could be displayed or pick out for solid modeling presentation for users.

Programming Code / CNC Controller

The system should able be interpreted any CNC controller programming format and even with specified standard canned cycles command

For this reasons, the system available programming format should contain not only standard G code command, but almost, such as dialogue types like Heidenhain or dialogue programming

The system also should allow of programming contour strings, tools tips and radius compensation, subroutines and variable parameters application, including arithmetical calculations.

FUNCTIONS Set-up Mode

All preparation prior to programming is carried out in the setup up mode. The system should be able to allows user setup up from :

Raw Part with different dimensioning and possibilities such as block, cylinder, pipe and custom-make casting part from CAD system.

Different raw part materials with detailed grade of each category with listed information such as strength, hardness, density and specified cutting force.

Clamping system such external, internal, collet, centre support (tailstock), sub-spindle and different jaws design for lathe simulator.

Clamping system such different size of vice, modular clamps, magnetic table for milling simulator. Positioning of work part with clamps and worktable.

The work part should be able to position in the clamps and follow by positioning within machine working table.

Different Tools, cutting tips, shape of cutting tips, tools holders or arbors are available in tools setup. User could self-design tools and holders such as special cutting and form tools is available for importing by pre- designed data from others CAD system.

System could be able to performance manual operation or MDI to move machine table, switch spindle, tool changing, manual cutting process, coolant, collision test.

Setup Form or process sheet will be automatically generated which should consist of production date, type of machine used, raw materials information and size, position of clamps and work part on machine working table, tools list in turret or magazine and tools compensation storage information.


(34)

NC Programming

Manual Programming as well as program modification and simulation are carried out via different possibilities :

Automatic mode Single block Tool tracing NC Editors

Re-numbering & auto assigned NC block number

Customized NC program with feature error detection can be carried out during input procedures Teach in

Machined by manual control on simulator and automatically converts the resulting traverse paths into ISO G code command and inserts them into the NC program

Interactive mode

Combines the NC editor and the automatics mode. After the entry of an NC block or a cycle in the NC command line corresponding machining is immediately executed.

In a subsequent dialogue the users is prompted to either correct or adopt the result NC Program Analysis System could performance machining analysis for single tool, material removal, machining time, overall cycle time and conclusion in lathe simulator.

Workshop Oriental Programming (WOP)

Using the WOP interface, complex contours can be programmed without furtherr aid. A dialogue system serves to query the geometry data given in the drawing The WOP system must consist of the measuring functions for generated contours Simulation

The automatic mode serves to test NC programs in a real time automatic run

Displayed machine status on screen during simulation and verification such as tool position coordinate, cutting speed and RPM, indication of spindle and coolant switch on or off, real running time, current modal activation G code and override

Displayed current NC Program block is being interpreted during simulation

During simulation or verification of NC p ( program, it should able be switched between the four NC programming modes such as automatic, single block, interactive and NC editor is possible at any time Dynamic simulation uses windows technology, which gives 2D and 3D views of machining of the work pieces including visible and open edges

Comprehensive Collision monitoring provides highly reliable detection and correction of program errors Recognition of removes materials and rest of materials


(35)

Measuring function could able be activated at any time during or end of simulation. Dimension control on depth, size (CNC Milling), point dimensioning, entities attributes check such as radius, angles, coordinates and surface roughness with Rmax and Rmin definition (CNC lathe)

Could able be displayed third angle projection and 3D presentation with different cross sectioning side and top view (CNC Milling).

The system could display 3D presentation with 360 degree or any view angle, zoom function and sections can be cut out of the 3D representation on finished part (CNC Turning)

End of simulation, process optimization (CNC lathe) could be carried out by machining and tools analysis function.

The analysis is been computed on each single tools machining time, overall machining time, cutting speed, length of travel path, removed materials volume and density of removed and rest of material

System Displayed Windows Performance Characteristics

The system must be using the digital vector technology or walk in function for performing overall machine The system-displayed machine could be able to free rotate with 360 degree dynamically by computer mouse to any required angle for verification

The system displayed machine room could be able to zoom dynamically by walk in command dynamically by computer mouse

All the machine components inclusive of part in the displayed room could able to pick out separately by mouse and display the detailed window for components information

CNC - Help / Online Tutorial Functions

The help system can be activated at any time while working on simulator

It should provide assistance in the solution of individual programming tasks with clear explanations of single NC command and basic information on CNC techniques

G code command with specified canned cycles, displayed with diagram, NC program example and explanation

Tools compensation information such G42, G41, G40 Cutter approach and retract cutting techniques

User could custom-make help dialogue box required specify information for individual application on specified CNC controller

It could input text and scanned picture for user custom-make dialogue box generation CAD/ CAM INTERFACE


(36)

Offer high performance functions for drawing data interchange by DXF and IGES format from others CAD system It could produce, update and document on imported technical drawing or self created in the system

The INCAD facilities the quick and simple generation of NC programs for Turning & Milling from drawing. In an interactive dialogue the geometric data from CAD drawing are combined with the appropriate tools and technologies and converted into NC program

POSTPROCESSOR AND GENERALIZED POSTPROCESSOR

Postprocessor are provided to translate the drawing into the NC syntax of any CNC control for Turning and Milling

The postprocessor converts the NC programs into elementary DIN/ISO code or the cycles of target control

Certain control characters such as for encoding starting program and program ending or line feeding can be defined by users

DNC TRANSMISSION FUNCTIONS AND PROGRAM

A transmission program transfers the converted NC programs directly to the machine, permitting variable configuration of the interface and of the control information for data transfer

PREPARATION MATERIALS AND DOCUMENTATION FOR CONDUCTING CNC TECHNOLOGIES FOR TURNING & MILLING

Hard and soft copies Requiress subjects such CNC Basic Knowledge CNC Turning & Milling CNC Exercises and Solution

HARDWARE / OPERATING SYSTEM REQUIREMENT Desktop PC

· Desktp PC used for student work for doing experiment, for the above.

· Platform Corporate Desktop PC

· Processor Type Intel Processor

· Standard Memory 2 GB

· Video Type 1 GB

· Audio Type Integrated

· Hard Drive Type 320 GB

· Optical Drive Type DVD±RW

· Network Speed 10 / 100 / 1000 Mbps


(37)

· Input Device Type Optical Scroll Mouse

· Slot Provided 2x PCI

· O/S Provided Microsoft* Windows XP Professional · Monitor Provided 22" flat LCD

· Chassis Form Factor Micro Tower ATX

· Standard Warranty 1-year Limited Warranty by Authorized Distributor

JUMLAH

……….….………. DIBULATKAN……….….………. TERBILANG: ……….……….……….…..(Dengan Huruf)

……….,……….. PENAWAR,

PT/CV,………..

……… DIREKTUR UTAMA/DIREKTUR


(1)

Variable presentation of results with simple integration of part-related graphics

Multimedia support for documenting the parts clamping and probe configuration for the CNC start

CAD-Interface STEP Converter USB Dongle Hardlock for CALYPSO Special Accessories

Refrigerated Air Dryer

Uninterruptible Power Supply (UPS) - 2kVA

33 CNC SIMULASI

11

License

MTS CNC Simulation Training System Ver 7.0 Simulation For Turning & Milling Process System Performance Characteristics

CONFIGURATION

The simulation system is an open system qualities, free configure in ANY system machine structure, CNC controllers in order to adapt the simulation system or simulator into different machine tools and controls system for training.

A comprehensive configuration program serves to adapt the system modules to given operation conditions as below :

Machine Tools

Free Configure into different dimension of the machining area

Free Configure into the traverse range of tool carriage, reference points, spindles, tool changer, different type of turret, magazine, tailstock and clamping device

Stationary and mobile components of the working area can be selected and configured in machine simulation

Number of tools in turret or magazine could free be able configured to maximum of 99 different tools Work Fixture

The work fixtures from lathe simulation system consist of spindle, chucks and jaws, collet and soft jaws. Chucking between centers is also possible.

Tailstock and centre sleeve are automatically adapted to geometric dimensions machine.

The milling simulation system consists of free configuration on machine worktable, vice, modular clamps and magnetic table.

It could be able to position or free moving the clamps and work part on pre-defined machine worktable and working range


(2)

Tools Systems

The tools systems consist of the support different cutting tools and tools holders

Each individual cutting tools with cutting tips could be free configured on shape of cutting tip, cutting angle (rake and clearance angle), in feed angle and adapt with different tools holder or arbor standard Each single tools could be displayed or pick out for solid modeling presentation for users.

Programming Code / CNC Controller

The system should able be interpreted any CNC controller programming format and even with specified standard canned cycles command

For this reasons, the system available programming format should contain not only standard G code command, but almost, such as dialogue types like Heidenhain or dialogue programming

The system also should allow of programming contour strings, tools tips and radius compensation, subroutines and variable parameters application, including arithmetical calculations.

FUNCTIONS Set-up Mode

All preparation prior to programming is carried out in the setup up mode. The system should be able to allows user setup up from :

Raw Part with different dimensioning and possibilities such as block, cylinder, pipe and custom-make casting part from CAD system.

Different raw part materials with detailed grade of each category with listed information such as strength, hardness, density and specified cutting force.

Clamping system such external, internal, collet, centre support (tailstock), sub-spindle and different jaws design for lathe simulator.

Clamping system such different size of vice, modular clamps, magnetic table for milling simulator. Positioning of work part with clamps and worktable.

The work part should be able to position in the clamps and follow by positioning within machine working table.

Different Tools, cutting tips, shape of cutting tips, tools holders or arbors are available in tools setup. User could self-design tools and holders such as special cutting and form tools is available for importing by pre- designed data from others CAD system.

System could be able to performance manual operation or MDI to move machine table, switch spindle, tool changing, manual cutting process, coolant, collision test.

Setup Form or process sheet will be automatically generated which should consist of production date, type of machine used, raw materials information and size, position of clamps and work part on machine working table, tools list in turret or magazine and tools compensation storage information.


(3)

NC Programming

Manual Programming as well as program modification and simulation are carried out via different possibilities :

Automatic mode Single block Tool tracing NC Editors

Re-numbering & auto assigned NC block number

Customized NC program with feature error detection can be carried out during input procedures Teach in

Machined by manual control on simulator and automatically converts the resulting traverse paths into ISO G code command and inserts them into the NC program

Interactive mode

Combines the NC editor and the automatics mode. After the entry of an NC block or a cycle in the NC command line corresponding machining is immediately executed.

In a subsequent dialogue the users is prompted to either correct or adopt the result NC Program Analysis System could performance machining analysis for single tool, material removal, machining time, overall cycle time and conclusion in lathe simulator.

Workshop Oriental Programming (WOP)

Using the WOP interface, complex contours can be programmed without furtherr aid. A dialogue system serves to query the geometry data given in the drawing The WOP system must consist of the measuring functions for generated contours Simulation

The automatic mode serves to test NC programs in a real time automatic run

Displayed machine status on screen during simulation and verification such as tool position coordinate, cutting speed and RPM, indication of spindle and coolant switch on or off, real running time, current modal activation G code and override

Displayed current NC Program block is being interpreted during simulation

During simulation or verification of NC p ( program, it should able be switched between the four NC programming modes such as automatic, single block, interactive and NC editor is possible at any time Dynamic simulation uses windows technology, which gives 2D and 3D views of machining of the work pieces including visible and open edges

Comprehensive Collision monitoring provides highly reliable detection and correction of program errors Recognition of removes materials and rest of materials


(4)

Measuring function could able be activated at any time during or end of simulation. Dimension control on depth, size (CNC Milling), point dimensioning, entities attributes check such as radius, angles, coordinates and surface roughness with Rmax and Rmin definition (CNC lathe)

Could able be displayed third angle projection and 3D presentation with different cross sectioning side and top view (CNC Milling).

The system could display 3D presentation with 360 degree or any view angle, zoom function and sections can be cut out of the 3D representation on finished part (CNC Turning)

End of simulation, process optimization (CNC lathe) could be carried out by machining and tools analysis function.

The analysis is been computed on each single tools machining time, overall machining time, cutting speed, length of travel path, removed materials volume and density of removed and rest of material

System Displayed Windows Performance Characteristics

The system must be using the digital vector technology or walk in function for performing overall machine The system-displayed machine could be able to free rotate with 360 degree dynamically by computer mouse to any required angle for verification

The system displayed machine room could be able to zoom dynamically by walk in command dynamically by computer mouse

All the machine components inclusive of part in the displayed room could able to pick out separately by mouse and display the detailed window for components information

CNC - Help / Online Tutorial Functions

The help system can be activated at any time while working on simulator

It should provide assistance in the solution of individual programming tasks with clear explanations of single NC command and basic information on CNC techniques

G code command with specified canned cycles, displayed with diagram, NC program example and explanation

Tools compensation information such G42, G41, G40 Cutter approach and retract cutting techniques

User could custom-make help dialogue box required specify information for individual application on specified CNC controller

It could input text and scanned picture for user custom-make dialogue box generation CAD/ CAM INTERFACE


(5)

Offer high performance functions for drawing data interchange by DXF and IGES format from others CAD system It could produce, update and document on imported technical drawing or self created in the system

The INCAD facilities the quick and simple generation of NC programs for Turning & Milling from drawing. In an interactive dialogue the geometric data from CAD drawing are combined with the appropriate tools and technologies and converted into NC program

POSTPROCESSOR AND GENERALIZED POSTPROCESSOR

Postprocessor are provided to translate the drawing into the NC syntax of any CNC control for Turning and Milling

The postprocessor converts the NC programs into elementary DIN/ISO code or the cycles of target control

Certain control characters such as for encoding starting program and program ending or line feeding can be defined by users

DNC TRANSMISSION FUNCTIONS AND PROGRAM

A transmission program transfers the converted NC programs directly to the machine, permitting variable configuration of the interface and of the control information for data transfer

PREPARATION MATERIALS AND DOCUMENTATION FOR CONDUCTING CNC TECHNOLOGIES FOR TURNING & MILLING

Hard and soft copies Requiress subjects such CNC Basic Knowledge CNC Turning & Milling CNC Exercises and Solution

HARDWARE / OPERATING SYSTEM REQUIREMENT Desktop PC

· Desktp PC used for student work for doing experiment, for the above. · Platform Corporate Desktop PC · Processor Type Intel Processor · Standard Memory 2 GB

· Video Type 1 GB

· Audio Type Integrated · Hard Drive Type 320 GB · Optical Drive Type DVD±RW

· Network Speed 10 / 100 / 1000 Mbps · Keyboard Type PS/2 Standard Keyboard


(6)

· Input Device Type Optical Scroll Mouse · Slot Provided 2x PCI

· O/S Provided Microsoft* Windows XP Professional · Monitor Provided 22" flat LCD

· Chassis Form Factor Micro Tower ATX

· Standard Warranty 1-year Limited Warranty by Authorized Distributor

JUMLAH

……….….………. DIBULATKAN……….….………. TERBILANG: ……….……….……….…..(Dengan Huruf)