Multi-type air conditioners refer to a type that has two or more indoor units connected Recycled plastic denotes part or all of plastic once used as a part of a useful product that

105 d. Does not use compressed motor. e. Uses energy other than electricity as a source of heat. f. The maintenance of machinery function or hygienic regulation of food. g. Primary function of the structure is to convey cooled outdoor air indoors. h. Target air conditioners. i. Air conditioners designed for use in automobiles and other vehicles. j. Duct air control system for highly airtight and highly insulated k. Structure includes regenerator includes those that are also used for heating exclusively for the purpose of storing heat for cooling. l. Structure operates compressor, fan, and other major components by electricity generated by own solar cell module. m. One having floor heating function or hot-water supply function. n. Heat recovery method multi air conditioner.

2. Multi-type air conditioners refer to a type that has two or more indoor units connected

to an outdoor unit. 3. Item 5 in Evaluation Criteria will apply to unit type air conditioners excludes packaged types, and labeling of content information of specific chemical substances will be indicated in accordance with JIS C 0950:2008 The marking for presence of the specific chemical substances for electrical and electronic equipment.

4. Recycled plastic denotes part or all of plastic once used as a part of a useful product that

has been discarded, remnants discarded during the manufacturing process, or the recyclereuse of defective articles This excludes, however, plastic that has been recycled in the process of manufacturing the product. 5. In order to manage chemical substances adequately, each procurement organization is to manage and maintain content information of specific chemical substances until the item in question is discarded. Table 1 : Standard Energy Consumption Efficiency for the Air-conditioners, applicable to Appendix 37 of Rules for Indicating Quality of Domestic Products, is a wall-mounted non-ducted type excluding multi-types with ability to control indoor units individually, with cooling ability of up to 4.0kW Category Standard energy consumption efficiency Cooling capacity Dimension type of indoor units Up to 3.2kW Dimension-defined type 5.8 Free-dimension type 6.6 Over 3.2 kW up to 4.0kW Dimension-defined type 4.9 Free-dimension type 6.0 Note: 1. Dimension type of indoor units denotes indoor unit means that air conditioner models whose indoor unit has horizontal width of 800 mm or less and height of 295 mm or less shall be defined as a dimension-defined type. Air conditioners other than those of dimension-defined type shall be free-dimension type. 2. Energy consumption is calculated according to “3 Energy Consumption Efficiency M easurement M ethods 2,” in M inistry of Economy, Trade and Industry notification No.213 June 22, 2009, based on the Law Concerning the Rational Use of Energy. Same applies for Table 2. 106 Table 2 : Standard Energy Consumption Efficiency for Domestic Air Conditioners Category Standard energy consumption efficiency Unit type Cooling capacity Non-ducted window wall-installed type Over 4.0 kW up to 5.0 kW 5.5 Over 5.0 kW up to 6.3 kW 5.0 Over 6.3 kW up to 28.0 kW 4.5 Non-ducted wall-mounted type except multi-type operating indoor units individually Up to 3.2 kW 5.2 Over 3.2 kW up to 4.0 kW 4.8 Over 4.0 kW up to 28.0kW 4.3 M ulti-type operating indoor units individually Up to 4.0 kW 5.4 Over 4.0 kW up to 7.1 kW 5.4 Over 7.1 kW up to 28.0 kW 5.4 Table 3 : Standard Energy Consumption Efficiency for Industrial Air Conditioners Category Standard energy consumption efficiency or its calculation formula Unit type and function Indoor unit type Cooling capacity Several combination or other than the below Cassette type for all sides Up to 3.6 kW E=6.0 Over 3.6 kW up to 10.0 kW E=6.0-0.083 x A-3.6 Over 10.0 kW up to 20.0 kW E=6.0-0.12 x A-10 Over 20.0 kW up to 28.0 kW E=5.1-0.060 x A-20 Other than cassette type for all sides Up to 3.6 kW E=5.1 Over 3.6 kW up to 10.0 kW E=5.1-0.083 x A-3.6 Over 10.0 kW up to 20.0kW E=5.1-0.10 x A-10 Over 20.0 kW up to 28.0kW E=4.3-0.050 x A-20 M ulti-type operating indoor units individually Up to 10.0 kW E=5.7 Over 10.0 kW up to 20.0 kW E=5.7-0.11 x A-10 Over 20.0 kW up to 40.0 kW E=5.7-0.065 x A-20 Over 40.0 kW up to 50.4 kW E=4.8-0.040 x A-40 Floor type Indoor units duct connected type or anything like this Non-duc ted type Up to 20.0 kW E=4.9 Over 20.0 kW up to 28.0 kW E=4.9 Ducted type Up to 20.0 kW E=4.7 Over 20.0 kW up to 28.0 kW E=4.7 Note: 1. Ducted type air conditioners refer to systems connected to ducts at the outlet. 2. E and A denotes the following. 107 2 Target Setting Guideline Ratio of the number of air conditioners meeting the criteria to the total number of air conditioners to be purchased including leaserental agreements in the fiscal year. 108 8-2. Gas Heat Pump Air Conditioners 1 Items and Evaluation Criteria Gas heat pump air conditioners Evaluation criteria 1 Coefficient of performance exceeds the number listed in the applicable category in Table. 2 Refrigerant does not include material capable of destroying the ozone layer. 109 Eeh 110 8-3. S pace Heaters 1 Items and Evaluation Criteria Space heaters Evaluation Criteria M ust fulfill at least one of below. 1Energy consumption efficiency in gas space heaters shall not fall below the standard energy consumption efficiency of applicable category in Table 1. 2Energy consumption efficiency in oil space heaters shall not fall below the standard energy consumption efficiency or its calculation formula of applicable category in Table 2. Factors for Consideration 1 The item is designed so that it can be easily dismantled and its materials separated to facilitate either reuse of components or recycling of materials. 2 The item is made of as large amount of recycled plastic as possible if plastic components are used. 3 Packaging and stowage is to be as simple as possible and take into account ease of recycling and reduced environmental impact upon disposal. 4 A system for the collection and reuserecycling of packaging, etc. is considered. Note: 1. Space heaters under consideration in the evaluation criteria of this section must use gas or oil, and should not meet any of the criteria below: a. The item employs non-vented types. b. The item uses gas excluding city gas categorized under group 13A Group specified in Article 25 Section 3 of Gas Industry Law Enforcement Regulation M inistry of International Trade and Industry Ordinance 97, 1970 and liquefied petroleum gas as its energy source. c. Vented gas space heaters. d. Vented oil space heaters with maximum fuel consumption rate greater than 4.0Lh. e. Direct vent type oil space heaters with maximum fuel consumption rate greater than 2.75Lh. 2. Recycled plastic denotes part or all of plastic once used as a part of a useful product that has been discarded, remnants discarded during the manufacturing process, or the recyclereuse of defective articles This excludes, however, plastic that has been recycled in the process of manufacturing the product. Table 1. Standard Energy Consumption Efficiency for Gas S pace Heaters Category Standard Energy Consumption Efficiency Direct vent type 82.0 Note: Energy consumption efficiency is calculated according to “3 Energy Consumption Efficiency M easurement M ethods,” in M inistry of Economy, Trade and Industry notification No. 55 M arch 29, 2006, based on the Law Concerning the Rational Use of Energy. Same applies for Table 2. 111 Table 2. Standard Energy Consumption Efficiency or Its Calculation Formula for Oil S pace Heaters Category Standard Energy Consumption Efficiency or Its Calculation Formula Air supply and exhaust type Heat transfer type Direct Vent Type Natural convection type 83.5 Forced convection type 86.0 Vented type Radiation type 69.0 Radiating type with maximum fuel consumption amount of 1.5Lh or less 67.0 Radiating type with maximum fuel consumption amount of over 1.5Lh E = -3.0 x L + 71.5 Note: E and L stand for the following: E: Standard energy consumption efficiency unit: L: M aximum fuel consumption amount unit: Lh 112

9. Water Heaters, etc. 9-1 Electric Hot Water S upply S ystem