No plating in barrel 2. Clinch required for Class 3, see 7.4.4 Lead form

Target – Class 1,2,3 • The entire body length of the component is in contact with the board surface. • Components required to be mounted off the board are at minimum 1.5 mm [0.06 in] from the board surface; e.g., high heat dissipating. • Components required to be mounted off the board are pro- vided with lead forms at the board surface or other mechanical support to prevent lifting of solder land. Defect – Class 1,2,3 • Components required to be mounted off the board are not provided with lead forms at the board surface or other mechanical support to prevent lifting of solder land. • Components required to be mounted above the board sur- face are less than 1.5 mm [0.06 in]. • Component height exceeds user-determined dimension. 1 2 Figure 7-121

1. No plating in barrel 2. Clinch required for Class 3, see 7.4.4

Figure 7-122

1. Lead form

Figure 7-123 Figure 7-124 7.4 Unsupported Holes 7-58 IPC-A-610F July 2014 7.4.1 Unsupported Holes – Axial Leads – Horizontal Target – Class 1,2,3 • Components that are mounted above the board surface in unsupported holes are provided with lead forms or other mechanical support to prevent lifting of solder land. Defect – Class 1,2,3 • Components mounted above the board in unsupported holes are mounted without lead form at the board surface or other mechanical support. Figure 7-125 Figure 7-126 7.4.2 Unsupported Holes – Axial Leads – Vertical 7-59 IPC-A-610F July 2014 Note: High frequency applications may require more precise control of lead extensions to prevent violation of functional design considerations. Acceptable – Class 1,2,3 • The leads protrude beyond the land within the specified minimum and maximum L of Table 7-6, provided there is no danger of violating minimum electrical clearance. Table 7-6 Protrusion of Leads in Unsupported Holes Class 1 Class 2 Class 3 L Min. End is discernible in solder Sufficient to clinch L Max. Does not violate minimum electrical clearance Note 1. Lead protrusion should not exceed 2.5 mm [0.1 in] if there is a possi- bility of violation of minimum electrical spacing, damage to soldered connec- tions due to lead deflection or penetration of static protective packaging during subsequent handling or operating environments. Defect – Class 1,2,3 • Lead protrusion does not meet Table 7-6 requirements. • Lead protrusion violates minimum electrical clearance. • Lead protrusion exceeds maximum design height require- ments. L L Figure 7-127 L L Min L Max Figure 7-128 7.4.3 Unsupported Holes – WireLead Protrusion 7-60 IPC-A-610F July 2014 This section applies to terminations with a clinching requirement. Other requirements may be specified on relevant specifications or drawings. Partially clinched leads for part retention are considered as unclenched leads and need to meet protrusion require- ments. The clinch should be sufficient to provide mechanical restraint during the soldering process. The orientation of the clinch relative to any conductor is optional. DIP leads should have at least 2 diagonally opposing leads partially bent outward. Tempered leads and leads greater than 1.3 mm [0.05 in] should not be bent nor formed for mounting purposes. Tempered leads are not termi- nated with a full-clinched configuration. The lead meets the requirements of Table 7-6 when measured vertically from the land surface and does not violate minimum elec- trical clearance requirements. Target – Class 1,2,3 • Lead end is parallel to the board and direction of the clinch is along the connecting conductor. Figure 7-129 7.4.4 Unsupported Holes – WireLead Clinches 7-61 IPC-A-610F July 2014 Acceptable – Class 1,2,3 • The clinched lead does not violate the minimum electrical clearance C between noncommon conductors. • The protrusion L beyond the land is not greater than the similar length allowed for straight-through leads. • The leads protrude beyond the land within the specified minimum and maximum L of Table 7-6, provided there is no violation of minimum electrical clearance. Acceptable – Class 3 • Lead in unsupported hole is clinched a minimum of 45°. Defect – Class 1,2,3 • The lead is clinched toward an electrically noncommon con- ductor and violates minimum electrical clearance C. • Lead protrusion is insufficient for clinch, if required. Defect – Class 3 • Lead in unsupported hole is not clinched a minimum of 45° not shown. C C L Figure 7-130 C C 1 Figure 7-131

1. Noncommon conductor