3.06
314
2. Mixing
Transfer the contents of Base and Activator containers from the
respective jars into the mixing container provided. Mix in the raio
indicated. Lids should be replaced immediately after use. The two
components should be thoroughly mixed until completely streak free and
a uniform colour is achieved, using the spatula provided.
3. Application
Prepared Surfaces should be dry. Using the spatula provided the mixed
material should be spread evenly onto the prepared area, working the
material into any cracks and surface defect. Once the CeramiGrade
Rebuild has reached initial set the material can be separated from
surfaces treated with release agent.
When CeramiGrade Rebuild is being used to repair leaking pipes, the
flow through the pipe should be discontinued until the repair is made
and the CeramiGrade Rebuild is set. Any leaking fluid must be wiped
from the prepared surface before undertaking the repair. When a
second coat is required, this should be done as soon as the first coat has
set. within 4 hours
4. Machining Once the CeramiGrade Rebuild has
cured for the minimum time indicated in the Curing Properties Section
of the product specification sheet, sanding, grinding and machining etc.
can be carried out using standard engineering practices.
5. Cleaning
All equipment should be cleaned IMMEDIATELY after each use with
a cleaner. Failure to follow this procedure will result in application
equipment becoming unusable.
6. Health and safety
As long as normal good practices are observed CeramiGrade Rebuild
can be safely used. A fully detailed Material Safety Data Sheet is
included with the set. The information provided in this Instruction sheet
is intended as a general guide only. Users should determined the
suitability of the product for their own particular purposes by their
own tests.
Corroded tube plates
Eroded impellers
3.06
315
3.06
316
Product specification sheet – Ceramigrade Liner
Product Description
Identification
Application Data
Chemical resistance Suitable for permanent immersion at 0 °C 68 °F in a limited range of chemicals. For a more detailed
description refer to the Chemical Resistance Chart.
Manufactured under a quality program certified to ISO 9002 Health and Safety
As long as good practice is observed CeramiGrade Liner can be safely used. Wearing of rubber gloves is advisable during use. Prior to using this product please consult the Safety Data Sheet
provided with each packaged product.
Mixing Ratio Mixing Ratio
Pot Life mins Volume
Weight Working Life
Activator Base Activator Base 5 °C
10 °C 15°C
0 °C 5 °C
30 °C 35 °C
40 °C 1
4 1
5 45
35 30
5 15
13 10
Curing Time
Curing Times in minutes at 5 °C
10 °C 15 °C
0 °C 5 °C
30 °C 35 °C
40 °C ambient temperature
Initial Setting Light Loading 300
40 10
180 180
150 130
10 Machining
360 300
70 40
40 10
190 180
Full Mechanical Strength 10 days 9 days 8 days 7 days 7 days 5 days 3 days days
Full Chemical Resistance 0 days 15 days 15 days 14 days 14 days 10 days 7 days 3 days
Activator Component Base Component
Appearance Colour
Appearance Colour
Liquid ClearAmber
Liquid Blue
Technical Data
PhysMec Properties
Density gcm
3
Volume Solids Volume Capacity
Slump Resistance
Activator Base Mixed cc1000gm
mm thickness 1,0
1,67 1,55
100 645
na Recommended Temperature Limits For Application: 5 °C TO 40 °C
Compressive Strength ASTM D41
70 MPa 1000 psi
Tensile Shear Adhesion ASTM D41
16 MPa 300 psi
Abrasion Resistance ASTM D4060
0,09 cc 100 cycles Corrosion Resistance
ASTM B117 5000 hours
Hardness Shore D ASTM D46
80 Impact Resistance
ASTM D56 5 kJm
Dry heat Wet heat
Minimum temp
+ 70 °C 158 °F + 60 °C 140 °F
- 0 °C - 4 °F Values are determined after 48 hours at 0 °C
Service Temperatures
PRODUCT NAME PRODUCT NO
KIT CONSISTS OF
Ceramigrade Liner Product No 102-659276
775 g Base + Activator Engineering Repair Fluid
Ceramigrade Liner 1 Mixing Container
0,5 ltr Engineering Repair 1 Pair of Gloves
Compound 1 Plastic Spatula
Supplied complete with all Gross Weight: 0,9 kg
1 Technical Data Sheet necessary equipment all in one
Safety Data Sheets
3.06
317
CeramiGrade Liner is a two component, solvent free, fast curing,
synthetic repair fluid. Areas of application : Re-building pumps,
impellers, propellers, turbine blades, valves etc.
1. Surface preparation