3.06
90
A fully detailed Material Safety Data Sheet is included with the set.
The information provided in this instruction for use sheet is intended
as a general guide only. Users should determine the suitability of
the product for their own particular purposes by their own tests.
Wrap while pulling firmly
Wet gloves, smooth out
3. Application
Remove roll from water and wrap quickly and tightly as follows: Centre
tape over leak site, wrap from bottom of roll, pulling firmly throughout
application. After 5–7 plies, you will observe resin foam coming through
the tape which is desirable and aided by pulling tightly. Continue until entire
roll is applied, building to a minimum thickness of 1 inch 1 mm and use
a second roll if necessary.
Firmly press and smooth end of roll into wrap in the direction of
application. Wet gloves in water, smooth and firmly press the wet resin
back into the wrap.
KEEP HANDS MOVING QUICKLY AND WET GLOVES FREQUENTLY TO AVOID
STICKING Continue rapid hand movement
pressing and polishing resin in motions around and parallel to the
pipe. Continue process until resins are no longer tacky.
The repair should now have a smooth hard surface and an enamel-like
appearance with no fibreglass substance showing throught the
resins.
NOTE: If thicker application is needed spend a little less time finishing the
first roll and immediately begin the application of the next. Finish the final
roll as if a single roll application.
4. Cleaning
After application dispose of gloves.
5. Health and safety
As long as normal good practices are observed Leak Stop can be safely
used.
3.06
91
The Leak Stop products are available in three sizes. The product is recommended for pressures up to 400 psi 8 bar.
Leak Stop III should be used in multiple roll applications
Nominal Number of
Pipe Size Leak Stop I rolls
50 psi3,5 bar 150 psi10,5 bar
400 psi8 bar 1 13 mm
1 1
1 34 19 mm
1 1
1 1 5 mm
1 1
1 14 1 mm 1
3 1 1 38 mm
3
Leak Stop I 100-630384
1 pc. x 4 50 mm x 1, m black repair tape in a pouch. For use on pipe diameter 0–1 0–5 mm.
If used outside this diameter area:
Nominal Number of
Pipe Size Leak Stop I rolls
50 psi3,5 bar 150 psi10,5 bar
400 psi8 bar 1 5 mm
1 1
1 1 1 38 mm
1 1
1 50 mm
1 1
1 1 63 mm
1 1
3 75 mm 1
3 1 88 mm 1
4 10 mm 1
5 15 mm 3
6 150 mm 4
8 00 mm 3
5 10 50 mm
3 4
6 1 300 mm
4 5
8 14 350 mm
4 6
8 16 400 mm
5 7
9 18 450 mm
5 8
9
Leak Stop III 100-630392
1 pc. 4 x 1 100 mm x 3,6 m black repair tape in a pouch. For use on pipe diameter –4 50–100 mm.
If used outside this diameter area:
Leak Stop II 100-606006
1 pc. x 1 50 mm x 3,6 m black repair tape in a pouch. For use on pipe diameter 1– 5–50 mm.
3.06
9
Product specification sheet – Metalgrade Ready-Stick Product
Description
Identification
Application Data
PRODUCT NAME PRODUCT NO
KIT CONSISTS OF
Metalgrade Ready-Stick Product No 101-659227
3 x 10 g Putty Base Engineering Repair Compound
Metalgrade Ready-Stick 3 x 10 g Putty Activator
Supplied complete with all 0,75 Kg Engineering Repair
1 Pair of Gloves necessary equipment all in one
Compound 1 Spatula
carton box set Gross Weight: 0,86 kg
1 Technical Data Sheet
Chemical resistance Suitable for permanent immersion at 0 °C 68 °F in a limited range of chemicals. For a more detailed
description refer to the Chemical Resistance Chart.
Manufactured under a quality program certified to ISO 9002 Health and Safety
As long as good practise is observed MetalGrade Ready-Stick can be safely used. Wearing of rubber gloves is advisable during use. Prior to using this product please consult the Safety Data Sheet
provided with each packaged product.
Mixing Ratio Mixing Ratio
Pot Life mins Volume
Weight Working Life
Activator Base Activator Base 5 °C
10 °C 15°C
0 °C 5 °C
30 °C 35 °C
40 °C 1
1 1
1 30
5 15
15 1
10 5
Curing Time
Curing Times in minutes at 5 °C
10 °C 15 °C
0 °C 5 °C
30 °C 35 °C
40 °C ambient temperature
Initial Setting Light Loading 80
60 45
35 30
8 6
Machining 180
10 90
70 60
60 55
45 Full Mechanical Strength
8 days 7 days 6 days 4 days 3 days days days 1 day Full Chemical Resistance
9 days 8 days 7 days 5 days 5 days 4 days 4 days 3 days
Activator Component Base Component
Appearance Colour
Appearance Colour
Putty Beige Brown
Putty Black
Technical Data
PhysMec Properties
Density gcm
3
Volume Solids Volume Capacity
Slump Resistance
Activator Base Mixed cc1000gm
15 mm thickness 1,95
1,96 1,96
100 500
Excellent Recommended Temperature Limits For Application: 5 °C TO 40 °C
Compressive Strength ASTM D41
70 MPa 1000 psi
Tensile Shear Adhesion ASTM D41
8 MPa 100 psi
Abrasion Resistance ASTM D4060
- Corrosion Resistance
ASTM B117 5000 hours
Hardness Shore D ASTM D46
80 Impact Resistance
ASTM D56 5 kJm
Values are determined after 48 hours at 0 °C
Service Temperatures
Dry heat Wet heat
Minimum temp
+ 90 °C 195 °F + 80 °C 176 °F
- 0 °C - 4 °F
3.06
93
MetalGrade Ready-Stick is a two component, solvent free, fast curing,
synthetic metal repair compound. Areas of application Sealing of leaks
in pipes, tanks, radiators, ducts etc.
1. Surface preparation