Cleaning Health and safety

3.06 90 A fully detailed Material Safety Data Sheet is included with the set. The information provided in this instruction for use sheet is intended as a general guide only. Users should determine the suitability of the product for their own particular purposes by their own tests. Wrap while pulling firmly Wet gloves, smooth out

3. Application

Remove roll from water and wrap quickly and tightly as follows: Centre tape over leak site, wrap from bottom of roll, pulling firmly throughout application. After 5–7 plies, you will observe resin foam coming through the tape which is desirable and aided by pulling tightly. Continue until entire roll is applied, building to a minimum thickness of 1 inch 1 mm and use a second roll if necessary. Firmly press and smooth end of roll into wrap in the direction of application. Wet gloves in water, smooth and firmly press the wet resin back into the wrap. KEEP HANDS MOVING QUICKLY AND WET GLOVES FREQUENTLY TO AVOID STICKING Continue rapid hand movement pressing and polishing resin in motions around and parallel to the pipe. Continue process until resins are no longer tacky. The repair should now have a smooth hard surface and an enamel-like appearance with no fibreglass substance showing throught the resins. NOTE: If thicker application is needed spend a little less time finishing the first roll and immediately begin the application of the next. Finish the final roll as if a single roll application.

4. Cleaning

After application dispose of gloves.

5. Health and safety

As long as normal good practices are observed Leak Stop can be safely used. 3.06 91 The Leak Stop products are available in three sizes. The product is recommended for pressures up to 400 psi 8 bar. Leak Stop III should be used in multiple roll applications Nominal Number of Pipe Size Leak Stop I rolls 50 psi3,5 bar 150 psi10,5 bar 400 psi8 bar 1 13 mm 1 1 1 34 19 mm 1 1 1 1 5 mm 1 1 1 14 1 mm 1 3 1 1 38 mm 3 Leak Stop I 100-630384 1 pc. x 4 50 mm x 1, m black repair tape in a pouch. For use on pipe diameter 0–1 0–5 mm. If used outside this diameter area: Nominal Number of Pipe Size Leak Stop I rolls 50 psi3,5 bar 150 psi10,5 bar 400 psi8 bar 1 5 mm 1 1 1 1 1 38 mm 1 1 1 50 mm 1 1 1 1 63 mm 1 1 3 75 mm 1 3 1 88 mm 1 4 10 mm 1 5 15 mm 3 6 150 mm 4 8 00 mm 3 5 10 50 mm 3 4 6 1 300 mm 4 5 8 14 350 mm 4 6 8 16 400 mm 5 7 9 18 450 mm 5 8 9 Leak Stop III 100-630392 1 pc. 4 x 1 100 mm x 3,6 m black repair tape in a pouch. For use on pipe diameter –4 50–100 mm. If used outside this diameter area: Leak Stop II 100-606006 1 pc. x 1 50 mm x 3,6 m black repair tape in a pouch. For use on pipe diameter 1– 5–50 mm. 3.06 9 Product specification sheet – Metalgrade Ready-Stick Product Description Identification Application Data PRODUCT NAME PRODUCT NO KIT CONSISTS OF Metalgrade Ready-Stick Product No 101-659227 3 x 10 g Putty Base Engineering Repair Compound Metalgrade Ready-Stick 3 x 10 g Putty Activator Supplied complete with all 0,75 Kg Engineering Repair 1 Pair of Gloves necessary equipment all in one Compound 1 Spatula carton box set Gross Weight: 0,86 kg 1 Technical Data Sheet Chemical resistance Suitable for permanent immersion at 0 °C 68 °F in a limited range of chemicals. For a more detailed description refer to the Chemical Resistance Chart. Manufactured under a quality program certified to ISO 9002 Health and Safety As long as good practise is observed MetalGrade Ready-Stick can be safely used. Wearing of rubber gloves is advisable during use. Prior to using this product please consult the Safety Data Sheet provided with each packaged product. Mixing Ratio Mixing Ratio Pot Life mins Volume Weight Working Life Activator Base Activator Base 5 °C 10 °C 15°C 0 °C 5 °C 30 °C 35 °C 40 °C 1 1 1 1 30 5 15 15 1 10 5 Curing Time Curing Times in minutes at 5 °C 10 °C 15 °C 0 °C 5 °C 30 °C 35 °C 40 °C ambient temperature Initial Setting Light Loading 80 60 45 35 30 8 6 Machining 180 10 90 70 60 60 55 45 Full Mechanical Strength 8 days 7 days 6 days 4 days 3 days days days 1 day Full Chemical Resistance 9 days 8 days 7 days 5 days 5 days 4 days 4 days 3 days Activator Component Base Component Appearance Colour Appearance Colour Putty Beige Brown Putty Black Technical Data PhysMec Properties Density gcm 3 Volume Solids Volume Capacity Slump Resistance Activator Base Mixed cc1000gm 15 mm thickness 1,95 1,96 1,96 100 500 Excellent Recommended Temperature Limits For Application: 5 °C TO 40 °C Compressive Strength ASTM D41 70 MPa 1000 psi Tensile Shear Adhesion ASTM D41 8 MPa 100 psi Abrasion Resistance ASTM D4060 - Corrosion Resistance ASTM B117 5000 hours Hardness Shore D ASTM D46 80 Impact Resistance ASTM D56 5 kJm Values are determined after 48 hours at 0 °C Service Temperatures Dry heat Wet heat Minimum temp + 90 °C 195 °F + 80 °C 176 °F - 0 °C - 4 °F 3.06 93 MetalGrade Ready-Stick is a two component, solvent free, fast curing, synthetic metal repair compound. Areas of application Sealing of leaks in pipes, tanks, radiators, ducts etc.

1. Surface preparation