3.06
94
3. Application
Prepared Surfaces should be dry. The mixed material should be pressed
firmly onto the prepared area, working the material into any cracks or
surface defects.
When MetalGrade Ready-Stick is used to repair leaking pipes, the
flow through the pipe should be discontinued until the repair is made
and the MetalGrade Ready-Stick is set. Any leaking fluid must be wiped
from the prepared surface before undertaking the repair.
4. Machining Once the MetalGrade Ready-Stick
has cured for the minimum time indicated in the Curing Properties
Section of the product specification sheet, sanding, grinding and
machining etc. can be carried out using standard engineering practices.
5. Cleaning
All equipment should be cleaned IMMEDIATELY after each use with
a cleaner. Failure to follow this procedure will result in application
equipment becoming unusable.
6. Health and safety
As long as normal good practices are observed MetalGrade Ready-
Stick can be safely used. A fully detailed Material Safety Data Sheet is
included with the set.The information provided in this Instruction for use
sheet is intended as a general guide only. Users should determined the
suitability of the product for their own particular purposes by their own
tests.
Valve taps
Pipe Joints
Hole in small diameter pipe
3.06
95
3.06
96
Product specification sheet – Metalgrade Express
Product Description
Identification Application
Data PRODUCT NAME
PRODUCT NO KIT CONSISTS OF
Metalgrade Express Product No 101-659235
435 g Base + Activator Engineering Repair Compound
Metalgrade Express 1 Mixing Container
0,5 ltr Engineering Compound 1 Pair of Gloves
Gross Weight: 0,86 kg 1 Spatula
1 Applicator Supplied complete with all
1 Roll reinforcement bandage necessary equipment all in one
1 Technical Data Sheet
Chemical resistance Suitable for permanent immersion at 0 °C 68 °F in a limited range of chemicals. For a more detailed
description refer to the Chemical Resistance Chart.
Manufactured under a quality program certified to ISO 9002 Health and Safety
As long as good practice is observed MetalGrade Express can be safely used. Wearing of rubber gloves is advisable during use. Prior to using this product please consult the Safety Data Sheet
provided with each packaged product.
Mixing Ratio Mixing Ratio
Pot Life mins Volume
Weight Working Life
Activator Base Activator Base 5 °C
10 °C 15°C
0 °C 5 °C
30 °C 35 °C
40 °C 1
1 0,9
1 8
5 4
3 1 3
1,5 1
Curing Time
Curing Times in minutes at 5 °C
10 °C 15 °C
0 °C 5 °C
30 °C 35 °C
40 °C ambient temperature
Initial Setting Light Loading 9
8 7
6 5
3 Machining
90 45
35 5
15 15
10 Full Mechanical Strength
300 150
10 90
80 70
60 40
Full Chemical Resistance 7 days 5 days 4 days 3 days days days 1 day
1 day
Activator Component Base Component
Appearance Colour
Appearance Colour
Paste Beige
Paste Metallic Grey
Technical Data
PhysMec Properties
Density gcm
3
Volume Solids Volume Capacity
Slump Resistance
Activator Base Mixed cc1000gm
15 mm thickness 1,6
1,8 1,7
100 585
Excellent Recommended Temperature Limits For Application: 5 °C TO 40 °C
Compressive Strength ASTM D695
47 MPa 7000 psi
Tensile Shear Adhesion ASTM D100
18,5 MPa 700 psi
Flexural Strength ASTM D790
48 MPa 6600 psi
Corrosion Resistance ASTM B117
5000 hours Hardness Shore D
ASTM D46 78
Hardness Rockwell R ASTM D785
100 Dielectric Strength
ASTM D149 30 voltsmil
Surface Resistivity ASTM D57
1 x 109 Ohmcm Values are determined after 48 hours at 0 °C
Service Temperatures
Dry heat Wet heat
Minimum temp
+ 80 °C 176 °F + 70 °C 158 °F
- 0 °C - 4 °F
3.06
97
MetalGrade Express is a two component, solvent free, fast curing,
synthetic metal repair compound. Areas of application Sealing of leaks
in pipes, tanks, radiators, ducts etc.
1. Surface preparation