Diameter dan tinggi clarifier

Kedalaman air = 3 – 10 m Settling time = 1 – 3 jam Dipilih : kedalaman air h = 5 m dan waktu pengendapan = 1 jam Diameter dan Tinggi clarifier Densitas larutan, 2.533 0,5472 2.710 1,0133 996,24 2 40.530,217 7 40.531,777 ρ + + = = 996,2501 kgm 3 Volume cairan, V = 3 3 m 6843 , 40 kgm 996,2501 jam 1 kgjam 7 40.531,777 = × Faktor kelonggaran = 20 Volume clarifier = 1,2 × 40,6843 m 3 = 48,8212 m 3

a. Diameter dan tinggi clarifier

∼ Volume silinder clarifier V s = Vs = Brownell Young, 1959 Perbandingan tinggi silinder dengan diameter tangki H s : D = 4 : 3 Vs = ∼ Volume alas clarifier kerucut V c ½ D H c Vs = ................................................................................ Perry, 1999 Perbandingan tinggi kerucut dengan diameter kerucut H c : D = 1:2 V c = ..................................................................................... Perry, 1999 ∼ Volume clarifier V V = V s + V e = H s ½ D Universitas Sumatera Utara 48,8212 m 3 = 1,178097 D 3 D = 3,4605 m = 11,3533 ft; H s = 43 × D = 4,614 m b. Diameter dan tinggi kerucut Perbandingan tinggi kerucut dengan diameter clarifier H h : D = 1: 2 Diameter tutup = diameter tangki = 3,4605 m Tinggi tutup =       2 m 3,4605 = 1,7303 m Tinggi total clarifier = 4,614 m + 1,7303 m = 6,3443 m c. Daya Pengaduk Daya Clarifier P = 0,006 D 2 ............................................................................... Ulrich, 1984 Di mana : P = daya yang dibutuhkan, kW Sehingga : P = 0,006 × 3,4605 2 = 0,0719 kW = 0,0964 hp Bila efisiensi motor = 60, maka : hp 1606 , 0,6 hp 0,0964 P = = Maka, dipilih motor dengan daya 14 hp. LD.12 Pompa Clarifier J-06 Fungsi : Mengalirkan air dari Clarifier V-05 ke Tangki Filtrasi V- 06 Bahan konstruksi : Commercial steel Kondisi operasi : Temperatur = 28 o C Densitas air ρ = 996,24 kgm 3 = 62,1939 lb m ft 3 Geankoplis, 2003 Viskositas air µ = 0,836 cP = 0,000562 lb m ft s Geankoplis, 2003 Laju alir massa F = 40.530,2172 kgjam Debit airlaju alir volumetrik, sjam 3600 996,24kgm kgjam 2 40.530,217 ρ F Q 3 × = = = 0,3991 ft 3 s = 0,0113 m 3 s Universitas Sumatera Utara Desain pompa : Untuk aliran turbulen, N Re 2100 Di ,opt = 0,363 × Q 0,45 × ρ 0,13 Peters, 2004 = 0,363 0,0113 m 3 s 0,45 996,24 kgm 3 0,13 = 0,1185 m = 4,664 in Dari Tabel A.5-1 Geankoplis, 2003, dipilih pipa dengan spesifikasi : Ukuran nominal : 5 in Schedule number : 40 Diameter Dalam ID : 5,047 in = 0,4206 ft Diameter Luar OD : 5,563 in = 0,4636 ft Luas penampang dalam A : 0,139 ft 2 Kecepatan linier, v = A Q = 2 3 ft 139 , s ft 3991 , = 2,871 fts Bilangan Reynold : N Re = µ D ρ × × v Peters, 2004 = lbmft.s 0.000562 ft 4206 , fts 871 , 2 lbmft 1939 , 62 3 × × = 133.680,8706 aliran turbulen Untuk pipa Commercial Steel, diperoleh harga ε = 0,000046 ; εD = 0,0001, pada N Re = 133.680,8706 diperoleh harga faktor fanning f = 0,00475 Geankoplis, 1997. Friction loss : 1 sharp edge entrance, h c = 0,55 × c v g . . 2 A A 1 2 1 2 α ×     − = 174 , 32 1 2 871 , 2 1 55 , 2 × − × = 0,0705 ft.lbflbm 3 elbow 90° h f = n.Kf. c v g 2 2 = 3.0,75 174 , 32 . 1 . 2 871 , 2 2 = 0,2882 ft.lbflbm Universitas Sumatera Utara 1 check valve h f = n.K.f. c v g . 2 2 = 1.2 174 , 32 . 1 . 2 871 , 2 2 = 0,2562 ft.lbflbm Pipa lurus 50 ft F f = 4f. c 2 D.2g ΔL.v = 4.0,00475. 174 , 32 2 . 4206 , 2,871 . 50 2 = 0,2893 ft.lbflbm 1 sharp edge exit h ex = n. c 2 2 2 1 g 2. α. . A A 1 v     − = 1. 174 , 32 1 2 871 , 2 . 1 2 2 − = 0,1281 ft.lbflbm Total friction loss ∑F = 1,0323 ft.lbflbm Dari persamaan Bernoulli : W F ρ P P z z g g g 2 1 s 1 2 1 2 c 2 1 2 2 c = + ∑ + − + − + − v v Geankoplis, 2003 Di mana : v 1 = v 2 ; ∆v 2 = 0 ; P 1 = P 2 ; ∆P = 0 tinggi pemompaan ∆z = 50 ft W 1,0323 50 . 32,174 32,174 s = + + + + -W s = 51,0323 ft.lbflbm Efisiensi pompa, η= 80 Wp = -Ws η = 63,7904 ft.lbflbm Daya pompa: P = m × Wp = ft.lbflbm ,7904 63 lbms 3600 0,45359 2 40.530,217 × × ft.lbfs 550 hp 1 = 2,8788 hp Digunakan daya motor standard 3 hp Universitas Sumatera Utara LD.13 Tangki Filtrasi V-06 Fungsi : Menyaring endapan flok-flok yang masih terikut dengan air yang keluar dari Clarifier V-05 Bentuk : Silinder vertikal dengan alas dan tutup datar Bahan konstruksi : Carbon steel SA-212, Grade B Jenis sambungan : Double welded butt joints Jumlah : 1 unit Kondisi operasi : Temperatur = 28 o C Laju massa air F = 40.530,2172 kgjam Densitas air ρ = 996,24 kgm 3 = 62,19389 lb m ft 3 Geankoplis, 2003 Tangki Filtrasi dirancang untuk penampungan 1 jam operasi. Direncanakan volume bahan penyaring = 1 3 volume tangki Faktor keamanan = 20 Tangki filtrasi dirancang untuk penampungan 14 jam operasi. Tangki filtrasi dirancang untuk volume bahan penyaring 13 volume tangki Perhitungan : a. Volume tangki Volume air, V a = 3 kgm 996,24 jam 0,25 kgjam 2 40.530,217 × = 10,1708 m 3 Volume tangki = 1,2 × 10,1708 m 3 = 13,5611 m 3

b. Diameter tangki