Pompa Utilitas 18 PU-118 Pompa Utilitas 19 PU-119 Pompa Utilitas 20 PU-120 Pompa Utilitas 21 PU-121
hl = 630 kJkg = 309,2007 Btulb App.D, Coulson, 1983
s = hv-hl
= 2.114,800 kJkg = 881,2564 Btulb e
b
= Effisiensi boiler = 80 Tabel. 4.8, Urich, 1984:109 F
= Nilai kalor bahan bakar Tab. 6-3, Ulrich, 1984:332
= 42 GJm
3
= 43.298,9691 kJkg = 18.615,2281 btulb.
m
f
=
1 18.615,228
8 ,
2007 ,
309 4571
, 190
. 1
627,9492 x
x
= 37,1594 lbjam = 16,8554 kgjam
= 0,0722 m³jam = 17,3764 literjam.
Hp boiler : 5
, 34
3 ,
970 x
h h
m hp
f f
Severn, Edisi kelima, hal. 142 = 1,0648 hp ~ 2 hp
Kapasitas boiler : 1000
f s
h h
m Q
Severn, Edisi kelima, hal. 139 = 553,3843 Btujam
= 583,8513 kJjam ρ
air
, 30
o
C = 992,1825 kgm
3
Heating surface : 1 hp boiler = 10 ft
2
heating surface total = 10 x hp boiler
= 10,648 ft
2
= 0,9892 m
2
Tabel. D.48. Spesifikasi Boiler BO-101
Alat Boiler
Kode
BO-101
Fungsi Menghasilkan steam untuk keperluan proses
Tipe Fire tube boiler
Heating surface
10,648 ft
2
Kapasitas
553,3843 Btujam
Power 2 hp