Data Hasil Percobaan Perhitungan

BAB IV HASIL DAN PEMBAHASAN

4.1 Data Hasil Percobaan

Table 4.1.1 Data Amoniak sampel air limbah pabrik kering No Kode Sampel Pengenceran Konsentrasi mgL Absorbansi 1 Inlet - 43,45 0,7694 - 43,45 0,7713 2 Outlet - 0,354 0,0879 - 0,376 0,0988 3 Inlet - 50,65 0,9112 - 50,65 0,9112 4 Outlet - 13,26 0,5665 - 13,28 0,5675 5 Inlet - 44,65 0,7930 - 44,65 0,7930 6 Outlet - 4,465 0,7930 - 4,475 0,7950 7 Inlet - 74,45 1,3799 - 74,75 1,3858 8 Outlet 50x 40,875 1,5356 1,5246 25x 40,90 Universitas Sumatera Utara Tabel 4.1.2 Data COD dari air Limbah Pabrik Kering No Kode Sampel Pengenceran V FAS KOK ml Kadar KOK mgL 1 Blanko - 11,65 - 2 Inlet - 6,75 403,26 6,80 3 Outlet - 10,85 60,8 10,90 4 Inlet - 5,8 481,844 5,85 4 Outlet - 10,25 113,74 10,30 5 Blanko 12,35 - 6 Inlet - 8,30 332,948 8,35 7 Outlet - 11,05 105,468 11,10 8 Blanko 10,95 - 9 Inlet - 0,80 904,772 0,85 10 Outlet - 10,30 58,088 55,852 10,35 Universitas Sumatera Utara

4.2 Perhitungan

4.2.1 Perhitungan Amoniak  100 ppm V 1 x N 1 = V 2 x N 2 V 1 1000 = 100 x 50 V 1 = 5 ml  10 ppm V 1 x N 1 = V 2 x N 2 V 1 100 = 10 X 100 V 1 = 10 ml  1 ppm V 1 x N 1 = V 2 x N 2 V 1 10 = 1 x 250 V 1 = 25 ml  2 ppm V 1 x N 1 = V 2 x N 2 V 1 10 = 2 x 50 V 1 = 10 ml Universitas Sumatera Utara • Pembuatan Larutan Seri Standart  0,1 ppm V 1 x N 1 = V 2 x N 2 V1 1 = 0,1 x 50 V 1 = 5 ml  0,3 ppm V 1 x N 1 = V 2 x N 2 V 1 1 = 0,3 x 50 V 1 = 15 ml  0,5 ppm V 1 x N 1 = V 2 x N 2 V 1 1 = 0,5 x 50 V 1 = 25 ml  0,7 ppm V 1 x N 1 = V 2 x N 2 V 1 1 = 0,7 x 50 V 1 = 35 ml Universitas Sumatera Utara • Metode Biasa X Y 0,0 0,0005 0,1 0,0402 0,3 0,1554 0,5 0,4030 0,7 0,4677 1,0 0,9434 2,0 1,9156 Keterangan: x = konsentrasi y = absorbansi • Metode Least Square X Y X 2 Y 2 XY 0,0 0,0005 0,00000025 0,1 0,0402 0,01 0,0016 0,0040 0,3 0,1554 0,09 0,0241 0,0466 0,5 0,4030 0,25 0,1624 0,2015 0,7 0,4677 0,49 0,2187 0,3273 1,0 0,9434 1 0,8900 0,9434 2,0 1,9156 4 3,6695 3,8312 Ʃx = 4,6 Ʃy = 3,9258 Ʃx 2 =5,84 Ʃy 2 =4,9663 Ʃxy =5,354 Universitas Sumatera Utara • Menentukan Nilai Slope a = = = = = 0,9847 • Menentukan nilai intersept b = = = = = -0,0863 Universitas Sumatera Utara • Persamaan garis regresi Y = ax + b Y 1 = 0,9847 0 + -0,0863 = 0,8984 Y 2 = 0,9847 0,1 + -0,0863 = 0,0121 Y 3 = 0,9847 0,3 + -0,0863 = 0,2091 Y 4 = 0,9847 0,5 + -0,0863 = 0,4060 Y 5 = 0,9847 0,7 + -0,0863 = 0,6029 Y 6 = 0,9847 1,0 + -0,0863 = 0,8984 Y 7 = 0,9847 2,0 + -0,0863 = 1,8831 • Tabel Harga Y baru larutan standart Ammonium X Y 0,8984 0,1 0,0121 0,3 0,2091 0,5 0,4060 0,7 0,6029 1,0 0,8984 2,0 1,8831 Universitas Sumatera Utara • Mencari Nilai Regresi r = 7 = = = = = 0,9940 • Perhitungan Absorbansi sampel y = ax +b • Inlet A y = ax +b = 0,9847 x 0,869 + -0,0863 = 0,7694 • Inlet B y = ax +b = 0,9847 x 0,871 + -0,0863 = 0,7713 Universitas Sumatera Utara • Otlet A y = ax +b = 0,9847 x 0,117 + -0,0863 = 0,0879 • Outlet B y = ax +b = 0,9847 x 0,188+ -0,0863 = 0,0988 • Inlet A y = ax +b = 0,9847 x 1,013 + -0,0863 = 0,9112 • Inlet B y = ax +b = 0,9847 x 1,013 + -0,0863 = 0,9112 • Outlet A y = ax +b = 0,9847 x 0,663 + -0,0863 = 0,5665 Universitas Sumatera Utara • Oulet B y = ax +b = 0,9847 x 0,664 + -0,0863 = 0,5675 • Inlet A y = ax +b = 0,9847 x 0,893 + -0,0863 = 0,7930 • Inlet B y = ax +b = 0,9847 x 0,893 + -0,0863 = 0,7930 • Outlet A y = ax +b = 0,9847 x 0,893 + -0,0863 = 0,7930 • Outlet B y = ax +b = 0,9847 x 0,895 + -0,0863 = 0,7950 Universitas Sumatera Utara • Inlet A y = ax +b = 0,9847 x 1,489 + -0,0863 = 1,3799 • Inlet B y = ax +b = 0,9847 x 1,495 + -0,0863 = 1,3858 • Outlet A y = ax +b = 0,9847 x 1,635 + -0,0863 = 1,5356 • Outlet B y = ax +b = 0,9847 x 1,636 + -0,0863 = 1,5246 • Perhitungan kadar sampel x = • Inlet A X 1a = x fp Universitas Sumatera Utara = 0,86 x 50 = 43,45 • Inlet B X 1a = x fp = 0,87093x 50 = 43,55 • Outlet A X 1a = x fp = 0,17691 x 2 = 0,354 • Outlet B X 1a = x fp = 0,18798 x 2 = 0,376 • Inlet A X 1a = x fp = 1,013 x 50= 50,65 • Inlet B X 1a = x fp = 1,013 x 50 = 50,65 • Outlet A X 1a = x fp = 0,66294 x 20= 13,26 Universitas Sumatera Utara • Outlet B X 1a = x fp = 0,66396 x 20= 13,28 • Inlet A X 1a = x fp = 0,89296 x 20= 44,65 • Inlet B X 1a = x fp = 0,89296 x 50 = 44,65 • Outlet A X 1a = x fp = 0,89296 x 5= 4,465 • Outlet B X 1a = x fp = 0,89499 x 5= 4,475 • Inlet A X 1a = x fp = 1,48898 x 50= 74,50 Universitas Sumatera Utara • Inlet B X 1a = x fp = 1,49497 x 50= 74,75 • Outlet A X 1a = x fp = 1,63491 x 25= 40,875 • Outlet B X 1a = x fp = 1,63593 x 25= 40,900 4.2.2 Perhitungan Kadar COD • Standarisasi larutan FAS 0,1 N Normalitas FAS = Dimana : V1 : Volume larutan K 2 Cr 2 K 7 ml N1 : Normalitas larutan K 2 Cr 2 K 7 N V2 : Volume yang dibutuhkan ml N1 = N2= = 0,1033 = 0,1035 Universitas Sumatera Utara N FAS = = = 0,1034 Perhitungan kadar sampel • Sampel inlet A KOK 1 = = 405,328 Sampel inlet B KOK 2 = = 401,192 KOK = KOK = = 403,26 • Sampel outlet B KOK 1 = = 66,176 Sampel outlet B KOK 2 = = 55, 424 KOK = Universitas Sumatera Utara KOK = = 60,8 • Sampel inlet A KOK 1 = = 483,912 Sampel inlet B KOK 2 = = 479,776 KOK = KOK = = 481,844 • Sampel outlet A KOK 1 = =115,808 Sampel outlet B KOK 2 = = 111,672 KOK = KOK = = 113,74 Universitas Sumatera Utara • Sampel inlet A KOK 1 = = 335,016 Sampel inlet B KOK 2 = = 330,88 KOK = KOK = = 332,948 • Sampe outlet A KOK 1 = = 107,536 Sampel outlet B KOK 2 = = 103,4 KOK = KOK = = 105,468 • Sampel inlet A Universitas Sumatera Utara KOK 1 = = 907,008 Sampel inlet B KOK 2 = = 902,536 KOK = KOK = = 904,772 • Sampel outlet A KOK 1 = = 58,088 Sampel outlet B KOK 2 = = 53,616 KOK = KOK = = 55,852 4.3 Pembahasan Universitas Sumatera Utara Hasil pengukuran yang dilakukan terhadap beberapa limbah cair pada pabrik kering dilakukan berdasarkan beberapa Parameter limbah cair yaitu COD Chemical Oxigen Demand dan Amoniak. Pada pengukuran COD untuk sampel outlet dan pengukuran Amoniak besarnya kadar total pada limbah cair tidak memenuhi baku mutu limbah cair industrisesuai dengan Kep.51MENLH101995. Dimana persyaratan kadar maksimumuntuk COD Chemical Oxygen Demand yaitu 300 mgliter dan kadar maksimum untuk Amoniak yaitu 10 mgliter. Dari beberapa hasil analisa ada sebagian sampel yang memenuhi standart baku mutu dan ada sampel yang tidak memenuhi standart baku mutu yang ditetapkan oleh Menteri Lingkungan Hidup, maka air limbah tersebut tidak dapat dibuang ke badan air untuk itu, perlu dilakukan pengolahan selanjutnya. Jika semakin tinggi kadar Amoniak dan COD akan bersifat toksik, dimana limbah tesebut akan dibuang ke badan sungai sehingga dapat berdampak buruk bagi organisme di sungai dan bagi pengguna sungai tersebut. Universitas Sumatera Utara

BAB V KESEMPULAN DAN SARAN