BAB IV HASIL DAN PEMBAHASAN
4.1 Data Hasil Percobaan
Table 4.1.1 Data Amoniak sampel air limbah pabrik kering
No Kode Sampel
Pengenceran Konsentrasi mgL
Absorbansi
1 Inlet
- 43,45
0,7694 -
43,45 0,7713
2 Outlet
- 0,354
0,0879 -
0,376 0,0988
3 Inlet
- 50,65
0,9112 -
50,65 0,9112
4 Outlet
- 13,26
0,5665 -
13,28 0,5675
5 Inlet
- 44,65
0,7930 -
44,65 0,7930
6 Outlet
- 4,465
0,7930 -
4,475 0,7950
7 Inlet
- 74,45
1,3799 -
74,75 1,3858
8 Outlet
50x 40,875
1,5356 1,5246
25x 40,90
Universitas Sumatera Utara
Tabel 4.1.2 Data COD dari air Limbah Pabrik Kering
No Kode Sampel
Pengenceran V FAS
KOK ml Kadar
KOK mgL
1 Blanko
- 11,65
- 2
Inlet -
6,75 403,26
6,80 3
Outlet -
10,85 60,8
10,90 4
Inlet -
5,8 481,844
5,85 4
Outlet -
10,25 113,74
10,30 5
Blanko 12,35
- 6
Inlet -
8,30 332,948
8,35 7
Outlet -
11,05 105,468
11,10 8
Blanko 10,95
- 9
Inlet -
0,80 904,772
0,85 10
Outlet -
10,30 58,088
55,852 10,35
Universitas Sumatera Utara
4.2 Perhitungan
4.2.1 Perhitungan Amoniak
100 ppm
V
1
x N
1
= V
2
x N
2
V
1
1000 = 100 x 50 V
1
= 5 ml
10 ppm V
1
x N
1
= V
2
x N
2
V
1
100 = 10 X 100
V
1
= 10 ml
1 ppm
V
1
x N
1
= V
2
x N
2
V
1
10 = 1 x 250
V
1
= 25 ml
2 ppm
V
1
x N
1
= V
2
x N
2
V
1
10 = 2 x 50
V
1
= 10 ml
Universitas Sumatera Utara
• Pembuatan Larutan Seri Standart
0,1 ppm
V
1
x N
1
= V
2
x N
2
V1 1 = 0,1 x 50
V
1
= 5 ml
0,3 ppm
V
1
x N
1
= V
2
x N
2
V
1
1 = 0,3 x 50
V
1
= 15 ml
0,5 ppm
V
1
x N
1
= V
2
x N
2
V
1
1 =
0,5 x 50 V
1
= 25 ml
0,7 ppm
V
1
x N
1
= V
2
x N
2
V
1
1 =
0,7 x 50 V
1
= 35 ml
Universitas Sumatera Utara
• Metode Biasa
X Y
0,0 0,0005
0,1 0,0402
0,3 0,1554
0,5 0,4030
0,7 0,4677
1,0 0,9434
2,0 1,9156
Keterangan: x = konsentrasi y = absorbansi
• Metode Least Square
X Y
X
2
Y
2
XY
0,0 0,0005
0,00000025 0,1
0,0402 0,01
0,0016 0,0040
0,3 0,1554
0,09 0,0241
0,0466 0,5
0,4030 0,25
0,1624 0,2015
0,7 0,4677
0,49 0,2187
0,3273 1,0
0,9434 1
0,8900 0,9434
2,0 1,9156
4 3,6695
3,8312 Ʃx = 4,6
Ʃy = 3,9258 Ʃx
2
=5,84 Ʃy
2
=4,9663 Ʃxy =5,354
Universitas Sumatera Utara
• Menentukan Nilai Slope
a = =
=
=
= 0,9847 •
Menentukan nilai intersept b =
=
=
=
= -0,0863
Universitas Sumatera Utara
• Persamaan garis regresi
Y = ax + b Y
1
= 0,9847 0 + -0,0863 = 0,8984 Y
2
= 0,9847 0,1 + -0,0863 = 0,0121 Y
3
= 0,9847 0,3 + -0,0863 = 0,2091 Y
4
= 0,9847 0,5 + -0,0863 = 0,4060 Y
5
= 0,9847 0,7 + -0,0863 = 0,6029 Y
6
= 0,9847 1,0 + -0,0863 = 0,8984 Y
7
= 0,9847 2,0 + -0,0863 = 1,8831 •
Tabel Harga Y baru larutan standart Ammonium X
Y 0,8984
0,1 0,0121
0,3 0,2091
0,5 0,4060
0,7 0,6029
1,0 0,8984
2,0 1,8831
Universitas Sumatera Utara
• Mencari Nilai Regresi
r =
7 =
=
=
=
= 0,9940 •
Perhitungan Absorbansi sampel y = ax +b
• Inlet A
y = ax +b = 0,9847 x 0,869 + -0,0863
= 0,7694 •
Inlet B y = ax +b
= 0,9847 x 0,871 + -0,0863 = 0,7713
Universitas Sumatera Utara
• Otlet A
y = ax +b = 0,9847 x 0,117 + -0,0863
= 0,0879 •
Outlet B y = ax +b
= 0,9847 x 0,188+ -0,0863 = 0,0988
• Inlet A
y = ax +b = 0,9847 x 1,013 + -0,0863
= 0,9112 •
Inlet B y = ax +b
= 0,9847 x 1,013 + -0,0863 = 0,9112
• Outlet A
y = ax +b = 0,9847 x 0,663 + -0,0863
= 0,5665
Universitas Sumatera Utara
• Oulet B
y = ax +b = 0,9847 x 0,664 + -0,0863
= 0,5675 •
Inlet A y = ax +b
= 0,9847 x 0,893 + -0,0863 = 0,7930
• Inlet B
y = ax +b = 0,9847 x 0,893 + -0,0863
= 0,7930 •
Outlet A y = ax +b
= 0,9847 x 0,893 + -0,0863 = 0,7930
• Outlet B
y = ax +b = 0,9847 x 0,895 + -0,0863
= 0,7950
Universitas Sumatera Utara
• Inlet A
y = ax +b = 0,9847 x 1,489 + -0,0863
= 1,3799 •
Inlet B y = ax +b
= 0,9847 x 1,495 + -0,0863 = 1,3858
• Outlet A
y = ax +b = 0,9847 x 1,635 + -0,0863
= 1,5356 •
Outlet B y = ax +b
= 0,9847 x 1,636 + -0,0863 = 1,5246
• Perhitungan kadar sampel
x =
• Inlet A
X
1a
= x fp
Universitas Sumatera Utara
= 0,86 x 50 = 43,45 •
Inlet B X
1a
= x fp
= 0,87093x 50 = 43,55 •
Outlet A X
1a
= x fp
= 0,17691 x 2 = 0,354 •
Outlet B X
1a
= x fp
= 0,18798 x 2 = 0,376 •
Inlet A X
1a
= x fp
= 1,013 x 50= 50,65 •
Inlet B X
1a
= x fp
= 1,013 x 50 = 50,65 •
Outlet A X
1a
= x fp
= 0,66294 x 20= 13,26
Universitas Sumatera Utara
• Outlet B
X
1a
= x fp
= 0,66396 x 20= 13,28 •
Inlet A X
1a
= x fp
= 0,89296 x 20= 44,65 •
Inlet B X
1a
= x fp
= 0,89296 x 50 = 44,65
• Outlet A
X
1a
= x fp
= 0,89296 x 5= 4,465 •
Outlet B X
1a
= x fp
= 0,89499 x 5= 4,475 •
Inlet A X
1a
= x fp
= 1,48898 x 50= 74,50
Universitas Sumatera Utara
• Inlet B
X
1a
= x fp
= 1,49497 x 50= 74,75 •
Outlet A
X
1a
= x fp
= 1,63491 x 25= 40,875 •
Outlet B X
1a
= x fp
= 1,63593 x 25= 40,900
4.2.2 Perhitungan Kadar COD •
Standarisasi larutan FAS 0,1 N Normalitas FAS =
Dimana : V1 : Volume larutan K
2
Cr
2
K
7
ml N1 : Normalitas larutan K
2
Cr
2
K
7
N V2 : Volume yang dibutuhkan ml
N1 = N2=
= 0,1033 = 0,1035
Universitas Sumatera Utara
N FAS = =
= 0,1034 Perhitungan kadar sampel
• Sampel inlet A
KOK 1 = = 405,328
Sampel inlet B
KOK 2 = = 401,192
KOK = KOK =
= 403,26
• Sampel outlet B
KOK 1 = = 66,176
Sampel outlet B
KOK 2 = = 55, 424
KOK =
Universitas Sumatera Utara
KOK = = 60,8
• Sampel inlet A
KOK 1 = = 483,912
Sampel inlet B
KOK 2 = = 479,776
KOK = KOK =
= 481,844
• Sampel outlet A
KOK 1 = =115,808
Sampel outlet B
KOK 2 = = 111,672
KOK = KOK =
= 113,74
Universitas Sumatera Utara
• Sampel inlet A
KOK 1 = = 335,016
Sampel inlet B
KOK 2 = = 330,88
KOK = KOK =
= 332,948
• Sampe outlet A
KOK 1 = = 107,536
Sampel outlet B
KOK 2 = = 103,4
KOK = KOK =
= 105,468
• Sampel inlet A
Universitas Sumatera Utara
KOK 1 = = 907,008
Sampel inlet B
KOK 2 = = 902,536
KOK = KOK =
= 904,772
• Sampel outlet A
KOK 1 = = 58,088
Sampel outlet B
KOK 2 = = 53,616
KOK = KOK =
= 55,852 4.3 Pembahasan
Universitas Sumatera Utara
Hasil pengukuran yang dilakukan terhadap beberapa limbah cair pada pabrik kering dilakukan berdasarkan beberapa Parameter limbah cair yaitu COD Chemical
Oxigen Demand dan Amoniak. Pada pengukuran COD untuk sampel outlet dan pengukuran Amoniak besarnya
kadar total pada limbah cair tidak memenuhi baku mutu limbah cair industrisesuai dengan Kep.51MENLH101995. Dimana persyaratan kadar maksimumuntuk COD
Chemical Oxygen Demand yaitu 300 mgliter dan kadar maksimum untuk Amoniak yaitu 10 mgliter.
Dari beberapa hasil analisa ada sebagian sampel yang memenuhi standart baku mutu dan ada sampel yang tidak memenuhi standart baku mutu yang ditetapkan oleh
Menteri Lingkungan Hidup, maka air limbah tersebut tidak dapat dibuang ke badan air untuk itu, perlu dilakukan pengolahan selanjutnya. Jika semakin tinggi kadar
Amoniak dan COD akan bersifat toksik, dimana limbah tesebut akan dibuang ke badan sungai sehingga dapat berdampak buruk bagi organisme di sungai dan bagi
pengguna sungai tersebut.
Universitas Sumatera Utara
BAB V KESEMPULAN DAN SARAN