P S14 =10,77kV x 1,97kA x0,94 = 19,6402 MW P S15 =10,78kV x 1,96kA x0,94 = 19,6402 MW P S16 =10,81kV x 1,95 kA x0,94 = 19,6115 MW P S17 =10,77kV x 1,95kA x0,94= 19,5389 MW P S18 =10,76kV x 1,94kA x0,94 = 19,5389 MW P S19 =10,77kV x 1,97kA x0,94 = 19,7597 MW P S20 =10,80kV x 1,97kA x0,94 = 19,7964 MW P S21 =10,81kV x 1,98kA x0,95 = 19,7964 MW P S22 =10,79kV x 1,96kA x0,95 = 19,6948 MW P S23 =10,76kV x 1,96kA x0,95 = 19,5389 MW P S24 =10,80kV x 1,96kA x0,94 = 19,6402 MW

4.1.2.1.3 Daya Pada Generator Fasa T

P T = V T .I T cos Ø P T1 = 10,81kV x 1,92kA x 0,94 = 19,5098 MW P T2 = 10,84kV x 1,93kA x 0,94 = 19,5641 MW P T3 = 10,82kV x 1,93kA x 0,94 = 19,4262 MW P T4 = 10,85kV x 1,93kA x 0,94 = 19,4801 MW P T5 = 10,92kV x 1,94kA x 0,94 = 19,7084 MW P T6 = 10,94kV x 1,95kA x 0,95 = 19,7445 MW P T7 = 10,86kV x 1,92kA x 0,94 = 19,4981 MW P T8 = 10,81kV x 1,95kA x 0,94 = 19,4083 MW P T9 = 10,90kV x 1,96kA x 0,94 = 19,7748 MW P T10 =10,80kV x 1,94kA x 0,94 = 19,5934 MW P T11 =10,80kV x 1,92kA x 0,95 = 19,3903 MW P T12 =10,80kV x 1,94kA x 0,95 = 19,4918 MW P T13 =10,78kV x 1,93kA x0,94= 19,3544 MW P T14 =10,78kV x 1,97kA x0,94 = 19,5347 MW P T15 =10,99kV x 1,96kA x0,94 = 19,4918 MW P T16 =10,80kV x 1,95 kA x0,94 = 19,2826 MW P T17 =10,74kV x 1,95kA x0,94= 19,4557 MW P T18 =10,78kV x 1,94kA x0,94 = 19,6402 MW P T19 =10,77kV x 1,97kA x0,94 = 19,8611 MW Universitas Sumatera Utara P T20 =10,78kV x 1,97kA x0,94 = 19,7964 MW P T21 =10,80kV x 1,98kA x0,95 = 19,7964 MW P T22 =10,80kV x 1,96kA x0,95 = 19,7964 MW P T23 =10,77kV x 1,96kA x0,95 = 19,6402 MW P T24 =10,78kV x 1,96kA x0,94 = 19,7597 MW Analisis Daya Generator Setelah Melakukan Pengukuran Total daya yang diberikan oleh sebuah generator tiga fasa atau yang diserap oleh suatu beban tiga fasa dapat diperoleh dengan menjumlahkan daya pada ketiga fasanya. Maka dapat dilakukan penghitungan dengan persamaan sebagai berikut : P = P R +P S +P T Maka pada saat tiam jam pengukuran yang dilakukan diperoleh nilai daya sebesar: P 1 = 19,5459 MW + 19,3424 MW + 19,5098 MW = 58,3981 MW P 2 = 19,6841MW + 19,4622 MW + 19,5641 MW = 58,8140 MW P 3 = 19,7204MW + 19,4317 MW + 19,4262 MW = 58,5964 MW P 4 = 19,7204 MW + 19,5159 MW + 19,4801 MW = 58,7164 MW P 5 = 19,9173 MW + 19,7265 MW + 19,7084 MW = 59,3486 MW P 6 = 20,0531 MW + 19,8492 MW + 19,7445 MW =59,6268 MW P 7 = 19,6543 MW +19,6543 MW +19,4981 MW = 58,8067 MW P 8 = 19,8331 MW +19,8514 MW +19,4083 MW = 59,0928 MW P 9 = 20,1006 MW +19,8773 MW +19,7748 MW = 59,7527 MW P 10 = 19,7496 MW +19,6296 MW +19,5934 MW = 58,9726 MW P 11 = 19,4918 MW +19,4918 MW +19,3903 MW = 58,3739 MW P 12 = 19,6948 MW +19,5098 MW +19,4918 MW = 58,6964 MW P 13 = 19,5571 MW +19,4918 MW +19,3544 MW = 58,4096 MW P 14 = 19,9438 MW +19,6402 MW +19,3544 MW = 58,9384 MW P 15 = 19,8611 MW +19,6402 MW +19,8347 MW = 59,3364 MW P 16 = 19,8147 MW +19,6115 MW +19,4918 MW = 58,9180 MW P 17 = 19,7414 MW +19,6115 MW +19,4918 MW = 58,5629 MW P 18 = 19,6219 MW +19,5389 MW +19,4557 MW = 58,6165 MW P 19 = 19,9438 MW +19,7597 MW+19,6402 MW = 59,3437 MW P 20 = 19,9994 MW +19,7964 MW+19,8611 MW = 59,6569 MW Universitas Sumatera Utara P 21 = 20,1196 MW +19,7964 MW+19,7964 MW = 59,7124 MW P 22 = 19,8795 MW +19,6948 MW+19,7964 MW = 59,3707 MW P 23 = 19,8242 MW +19,5389 MW+19,6402 MW = 59,5903MW P 24 = 19,8979 MW +19,6402 MW+19,7597 MW = 59,2978 MW Maka dari penghitungan diatas, maka dapat dicari rata-rata daya yang dihasilkan oleh generator tiga fasa dengan persamaan : N P P P P N + + + = ... 2 1 Dimana N adalah jumlah berapa kali dilakukan pengukuran. Maka : 24 MW 59,2978 59,5903MW MW 59,3707 MW 59,7124 MW 59,6569 MW 59,3437 MW 58,6165 MW 58,5629 MW 58,9180 MW 59,3364 MW 58,9384 MW 58,4096 MW 58,6964 MW 58,3739 MW 58,9726 MW 59,7527 MW 59,0928 MW 58,8067 MW 59,6268 MW 59,3486 MW 58,7164 MW 58,5964 MW 58,8140 MW 58,3981                 + + + + + + + + + + + + + + + + + + + + + + + = P MW P 24 9553 , 1309 = MW P 5814 , 54 = Jadi daya yang dihasilkan oleh generator pembangkit listrik PLTG Paya Pasir setiap saatnya adalah sebesar 54,5814 MW. Sesuai dengan data teknis generator dapat kita analisis bahwa generator Nanjing Turbine Electric Mschinery Group CO.LDT dapat kita dapatkan efisiensinya : 100 x P P P P teknis teknis     − = 100 5 , 52 5 , 52 5814 , 54 x P       − = 100 5 , 52 0814 , 2 x P       = 96 , 3 100 0396 , = = P x P Universitas Sumatera Utara Jadi efisiensi daya pada generator pembangkit PLTG Paya Pasir Medan Buatan pabrik Nanjing Turbine Electric Mechinery Group CO.LDT, china sebesar 3,96 artinya bahwa generator pembangkit PLTG Paya Pasir Medan masih dapat bekerja optimal dan masih melebihi daya maksimal yang seharusnya dapat dihasilkan oleh generator yaitu sebesar 2,079 MW setiap saatnya. 4.3 Analisis Suplay Daya PLTG Paya Pasir 4.3.1 Analisis Suplay Daya PLTG Paya Pasir Pada Bulan Februari 2009 Dalam tugasnya menghasilkan energi listrik dibawah naungan PLN pembangkitan Sumbagut, PLTG Paya pasir ditargetkan memproduksi daya sebesar 38 MW. Sesuai dengan perhitungan daya hasil dari generator pembangkit PLTG Paya Pasir diatas kita peroleh dayanya sebesar 57,8018 MW. Dengan menganalisis daya tersebut maka PT PLN Paya Pasir Medan masih dapat mensuplay daya listrik kepada PT PLN lain yang membutuhkan sebesar 57,8018MW – 38 MW = 19,8018 MW.

4.3.2 Analisis Suplay Daya PLTG Paya Pasir Pada bulan Juli 2009