KESIMPULAN DAN SARAN Prof. Dr. Harlem Marpaung, MS 4. Drs. Chaeruddin M.Sc

BAB V KESIMPULAN DAN SARAN

5.1. Kesimpulan ............................................................................ 53 5.2. Saran ...................................................................................... 54 DAFTAR PUSTAKA.. ................................................................................... 55 LAMPIRAN Universitas Sumatera Utara KAJIAN AIR LINDI DI TEMPAT PEMBUANGAN AKHIR TERJUN MENGGUNAKAN METODE THORNTHWAITE ABSTRAK Sampah merupakan persoalan rumit dihadapi oleh pengelola kota dalam menyediakan sarana dan prasarana kota. TPA Terjun berlokasi di Kelurahan Terjun Kecamatan Medan Marelan yang dioperasikan dengan system open dumping . Open dumping banyak menimbulkan masalah lingkungan dan sosial akibat lindi yang keluar. Penelitian ini untuk mengevaluasi kesesuaian lahan TPA Terjun sebagai TPA Kota Medan berdasarkan SNI dan USDA, menghitung jumlah air lindi dengan menggunakan neraca Thorntwaite, menganalisis kualitas air lindi di TPA Terjun dan menganalisis alternatif sistem pengolahan lindi. Luas pengelolaan sampah TPA Terjun dengan menggunakan model tracks pada Global Positioning System GPS yang kemudian diolah dengan program Argis dan dibuat dalam bentuk peta. Evaluasi lahan TPA Terjun berdasarkan SNI 03-3241- 1997 tentang Tata Cara Pemilihan Lokasi TPA masih ada kriteria yang belum sesuai SNI, diantaranya muka air tanah, kelulusan tanah dan daerah banjir ulang pada periode 25 tahun. Evaluasi lahan TPA Terjun berdasarkan United States Department of Agriculture USDA tahun 1971 berada pada kategori sedang untuk faktor pembatas ancaman banjir dan muka air tanah. Komposisi sampah organik TPA Terjun sebesar 74,07 . Data Hujan dan Temperatur bulanan selama 5 Tahun dari Tahun 2007 sampai Tahun 2011 dengan metode Thornthwaite mendapatkan nilai perkolasi 376 mm dan volume lindi yang dikelola 11.882 m 3 . Perkolasi tertinggi terjadi pada bulan Oktober yaitu 124,9 mm dengan luas lahan 3,16 Ha diperoleh debit 3946,84 m 3 bulan atau 1,5 ltdthr. Kualitas lindi Tahun 2011 menunjukkan parameter BOD dan COD berada diatas ambang batas yang telah ditetapkan PPRI No.82 Tahun 2001 Tentang Pengelolaan Kualitas Air dan Pengendalian Pencemaran Air Kelas IV yaitu sebesar 322 dan 540 mgl. Pembuataan Instalasi Pengolahan Lindi dimulai dengan pembuatan saluran pengumpul lindi menggunakan sistem perpipaan yang bermuara ke bangunan instalasi pengolahan lindi. Instalasi Pengolah Lindi TPA Terjun untuk menyisihkan BOD adalah kolam stabilisasi secara alamiah, dilanjutkan dengan kolam aerasi secara mekanis dan kolam filtrasi sorpsi. Kata Kunci :Tempat Pembuangan Akhir TPA, Lindi, Thornthwaite, Instalasi Pengolahan Lindi Universitas Sumatera Utara THE STUDY OF LECHATE IN TERJUN DUMP SITE THROUGH THORNTHWAITE METHOD ABSTRACT Municipal solid waste MSW is a difficult problem faced by the city management in providing city facilities and infrastructures. Terjun Dump Site operated in open-dumping system is located in Kelaurahan Terjun, Medan Marelan Subdistrict. Open dumping system has created a lot of social and environmental problems because of the seeping-out lechate. The purpose of this study was to evaluate the suitability of terjun dump site area as the dump site for the City of Medan based on SNI and USDA, to calculate the amount of lechate by using Thornwaite scale, to analyze the quality of lechate ar Terjun dump site, and to analyze the alternative lechate treatment. The area of MSW processing site of Terjun dump site is determined by using tracks model in Global Positioning System GPS and then is processed by using Argis program and is made in the form of map. The evaluation of Terjun dump site area based on the SNI 03-3241- 1997 on the Procedure of selecting the Location for dump site showed that there are criteria which are not in accordance with the SNI such as the ground water table, land grade and recurring flood zones for the period of 25 years. The evaluation of Terjun dump site are based on the United States Department of Agroculture USDA in 1971 showed that the factors of flood barier and ground water table belonged the adequate category. The composition of orgnic MSW at Terjun dump site was 74,07. The data of monthly rain and temperature for 5 five years from 2007 to 2011 processed with Thornwaite method showed that the value per location was 376 mm and the volume of the lechate processed was 11,882 m3. The highest value per location occured in october was 124,9 mm with the land area of 3,16 hectares with the debits of 3946,84 m3moth or 1,5Lsecondhour. The quality of lechate in 2011 showed that the parameter of BOD and COD wasa above rhreshold determined by the Government Regulation No. 822001 on Water Quality Processing and Water Pollution Control Class IV for 322 an 540 mL. The construction of lechate processing installation was begun with the making of lechate collecting ducts using piping system which leads to the lechate processing installation building. The lechate processing installation of Terjun dump site to separate the BOD is natural stabilization pond, the followed by mechanical aeral and filtration sorption ponds. Keywords : Dump site, Lechate, Thornwaite, Lechate Processing Installation Universitas Sumatera Utara

BAB I. PENDAHULUAN