Tabel 4.2 Hasil kapasitas daya dukung tiang Bore Pile dari data loading test dengan metode Davisson dan Mazurkiewicz.
No. Cycle No. Urut
Jam Test load
ton Duration
hari Penurunan rata -
rata mm Cycle I
1 13.37
0.00 0.00
0.00 2
25 14.37
103.75 0.0417
-0.32 3
50 14.41
207.50 0.0017
-1.96 4
25 16.42
103.75 0.0838
-1.49 5
17.03 0.00
0.0254 -0.94
Cycle II 6
50 18.09
207.50 0.0442
-1.94 7
75 18.32
311.25 0.0096
-2.93 8
100 19.35
415.00 0.0429
-5.69 9
75 21.36
311.25 0.0837
-5.64 10
50 21.57
207.50 0.0088
-4.82 11
22.18 0.00
0.0254 -2.49
Cycle III
12 50
23.20 207.50
0.0425 -3.53
13 100
23.42 415.00
0.0092 -5.81
14 125
24.03 518.75
0.0254 -7.58
15 150
1.04 622.50
0.9579 -10.43
16 125
3.05 518.75
0.0838 -10.75
17 100
3.26 415.00
0.0088 -10.02
18 50
3.47 207.50
0.0088 -7.86
19 4.08
0.00 0.0254
-3.52
Cycle IV
20 50
5.09 207.50
0.0421 -5.68
21 100
5.30 415.00
0.0088 -7.90
22 150
5.51 622.50
0.0088 -10.79
23 175
6.12 726.25
0.0254 -14.89
24 200
7.2 830.00
0.0450 -24.82
25 175
7.21 726.25
0.0004 -24.64
26 150
7.42 622.50
0.0088 -23.42
27 100
8.03 415.00
0.0254 -20.85
28 50
8.24 207.50
0.0088 -17.50
29 8.45
0.00 0.0087
-10.74
4.3.2 Metode Mazurkiewicz
Dengan menggambarkan garis ini pada kurva beban penurunan diperoleh beban maksimum Q
u
Dengan menggambarkan garis persamaan 45 = 820 ton Gambar 4.5
o
, maka Q
ult.
dari hasil perhitungan loading test
dan pemodelan elemen hingga dengan mempergunakan analitis dapat
Universitas Sumatera Utara
disimpulkan bahwa daya dukung ultimit berdasarkan loading test dengan metode Mazurkiewics 820 ton sedangkan metode finite element sebesar 765 ton. Gambar beban
penurunan ini dapat dilihat pada Gambar 4.5.
Gambar 4.5 Beban dan penurunan metode Mazurkiewicz Q
u
=840 ton, Perhitungan daya dukung tiang bore pile dari data SPT memakai metode Reese
Wright dan data diambil pada titik BH-1dalam 7 hari dapat dirangkum dalam Tabel 4.3 Tabel 4.3 Beban 100,150, 200 loading test untuk penurunan 7 hari
-25,00 -20,00
-15,00 -10,00
-5,00 0,00
200 400
600 800
1000
P E
NURUNA N
m
TEST LOAD TON
Cycle1 Cycle2
Cycle3 Cycle4
Universitas Sumatera Utara
No. Cycle
No. Urut
Jam Test
Duration Penurunan
load hari
rata-rata ton
mm
Cycle I 1
13.37 0.00
0.00 0.00
2 25
14.37 103.75
0.0417 -0.32
3 50
14.41 207.50
0.0017 -1.96
4 25
16.42 103.75
0.0838 -1.49
5 17.03
0.00 0.0254
-0.94
Cycle II 6
50 18.09
207.50 0.0442
-1.94 7
75 18.32
311.25 0.0096
-2.93 8
100 19.35
415.00 0.0429
-5.69 9
75 21.36
311.25 0.0837
-5.64 10
50 21.57
207.50 0.0088
-4.82 11
22.18 0.00
0.0254 -2.37
Cycle III 12
50 23.20
207.50 0.0425
-3.59 13
100 23.42
415.00 0.0092
-5.82 14
125 24.03
518.75 0.0254
-7.59 15
150 1.04
622.50 0.0421
-10.61 16
125 3.05
518.75 0.0838
-10.82 17
100 3.26
415.00 0.0088
-10.06 18
50 3.47
207.50 0.0088
-7.89 19
4.08 0.00
0.0254 -4.50
Cycle IV 20
50 5.09
207.50 0.0421
-5.71 21
100 5.30
415.00 0.0088
-7.90 22
150 5.51
622.50 0.0088
-10.81 23
175 6.12
726.25 0.0254
-14.94 24
200 7.2
830.00 0.0450
-24.74 25
175 7.21
726.25 0.0004
-24.70 26
150 7.42
622.50 0.0088
-23.52 27
100 8.03
415.00 0.0254
-20.75 28
50 8.24
207.50 0.0088
-17.46 29
8.45 0.00
0.0087 -10.59
1 13.37
0.00 0.0000
0.00
Untuk beban ultimit loading terhadap kedalaman tanah tidak dapat diperoleh dari data loading test karena pada loading test tidak tercantum kedalaman tanah kemungkinan
dari finite element. Penurunan dalam 7 hari akibat beban hasil loading test dapat dilihat
Universitas Sumatera Utara
pada Gambar 4.6 dimana beban maksimum 830 ton, dengan penurunan maksimum 24,82 mm. Hasil diperoleh dari Tabel 4.3.
Gambar 4.6 Beban 100,150, 200 loading test Penurunan dalam 7 hari,
4.4 Menghitung Kapasitas Daya Dukung Tiang Bored Pile, pada Titik 257