86
SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011.
in Microsoft Excel using built-in templates, on-board memory up to 3,500 measurements, audio output for listening to bearing tones directly, external
accelerometer support for hard to reach locations, has flashlight and large screen. Provides Crest Factor + for bearing assessment. Include tool bag for motor inspection
kit.
30 Low frequency range : 10 Hz to 1,000 Hz
31 High frequency range : 4,000 Hz to 20,000 Hz
32 Severity levels : Good, Satisfactory, Unsatisfactory, Unacceptable
33 Vibration meter limit : 50 g peak 100 g peak-peak
34 Sampling rate : 20,000 Hz low frequency, 80,000 Hz high frequency
35 Signal to noise ratio : 80 dB
36 Sensor sensitivity : 100 mV g ± 10
37 Sensor measurement range : 0.01 g to 50 g, resolution 0.01 g
38 Amplitude units : g, msec² acceleration, insec, mmsec velocity, mils, mm
displacement 39
Real time clock backup : coin battery 40
Temperature measurement : -20 °C to 200 °C , accuracy ±2 °C 41
Connectors : USB mini-B 7-pin, stereo audio output jack 3.5 mm Audio Plug, external sensor jack SMB connector
42 Must have Supporting letter from principal and supporting letter from local support
Distributor in indonesia
c. Specific measuring device for area compliance inspection
1 Electrical tools for HVAC and indoor air quality checking, using 5 in 1 tool to measure
temperature, velocity, humidity, CO2, CO, also dew point and wet bulb temperature as well, that can simultaneously measure and logging. Tools are completed with stand-
alone temperature-humidity meter with 99 record storage capacity and ergonomic design with clip and protective holster, and complete with tool to measure airflow,
velocity and differential pressure that can measure pressure drops across key HVAC equipment to drive peak performance and extend equipment life, include 12 inch pitot
tube, rubber hoses, latch tab, magnetic strip, 9 inch strap. 5 in 1 tool measure : temperature, relative humidity, air velocity, CO and CO2
Temperature range: -20 °C to 50 °C -5 °F to 122 °F ; display resolution: 0.1 °C 0.1 °F ; accuracy:
± 0.9 °C± 1.62°F from 40 °C to 60 °C ; ± 0.5 °C± 1.00°F from 5 °C to 40 °C Relative humidity range: 10 to 90 RH, non-condensing ; display resolution: 1 ;
accuracy: up to ± 2 RH Air velocity range: 50.0 fpm to 3000 fpm ; 0.25 msec to 15 msec ; display Resolution:
1 fpm 0.005msec ; curacy: ±4 or 4 fpm ; ±4 or 0.02 msec
C0 Range: 0 to 500 ppm ; display Resolution: 1 ppm ; accuracy: ± 5 or ± 3 ppm C02 Range: 0 to 5000 ppm ; display resolution: 1 ppm ; accuracy: 2.75 + 75 ppm
Dew point temperature range: -44 °C to 50 °C, -47 °F to 122 °F ; display resolution: 0.1 °C 0.1 °F ; accuracy: ± 1 °C
Wet bulb temperature range: -16 °C to 50 °C, 3 °F to 122 °F ; display resolution: 0.1 °C, 0.1 °F ; accuracy: up to ± 1.2 °C
Volume flow rate in a duct range: 0 to 3,965 M3m, 0 to 140,000 cfm ; display resolution: 0.001 M3min, 1 cfm
outside air based on temperature range: 0 to 100 ; display resolution: 0.1 ; outside air based on CO2 Range: 0 to 100 ;
87
SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011.
display resolution: 0.1 Data logging : 25,000 records continuous, 99 records discrete ; Rechargeable Li-Ion
primary, three-AA backup battery Stand-alone temperature-humidity meter :
Temperature : -20°C to 60°C -4°F to 140°F ; temperature accuracy up to ±0.5°C ; resolution : 0.1°C 0.1°F ;
Temperature Sensor Type : NTC ; Temperature Update Rate : 500 ms Relative Humidity Range : 5 to 95 RH ; accuracy : up to ±2.5RH
Response Time Humidity : up to 60 sec. with 1ms air movement ; Humidity Sensor : electronic capacitance polymer film sensor
Data storage capacity : 99 points Airflow meter :
Air Pressure : RangeResolutionAccuracy ± 4000 Pascals 1 Pascal ± 1 + 1 Pascal ; ± 16 in H2O 0.001 in H2O ± 1 + 0.01 in H2O ;
± 400 mm H2O 0.1 mm H2O ± 1 + 0.1 mm H2O ; ± 40 mbar 0.01 mbar ± 1 + 0.01 mbar ; ± 0.6 PSI 0.0001 PSI ± 1 + 0.0001 PSI
Air Velocity : RangeResolutionAccuracy 250 to 16,000 fpm 1 fpm ± 2.5 of reading at 2000 fpm 10.00 ms ;
1 to 80 ms 0.001 ms ± 2.5 of reading at 2000 fpm 10.00 ms Air Flow Volume : RangeResolutionAccuracy 0 to 99,999 cfm 1 cfm Accuracy is a
function of velocity and duct size ; 0 to 99,999 1 m3hr Accuracy is a function of velocity and duct size ; 0 to 99,999 ls
1 ls Accuracy is a function of velocity and duct size Data storage capacity : 99 readings
EMI, RFI, EMC Vibration : Meets requirements for EN61326-1 ; MIL-PREF-28800F, Class 3
IP54 distance meter for indoor and limited outdoor application with bright laser and inclination sensor, phythagoras calculation,
tripod mode, storage for quick recall of distance, compass and automated endpiece correction.
Range at Leica target plate GZM26 : 100 m330 ft Typical range : 80 m260 ft
Typical measuring tolerance : ± 1.0 mm Smallest unit displayed : 1 mm 132 in
Measuring tolerance to laser beam to housing : ± 0.2° Tilt measurement range : 360°
Calibration cycle : Tilt and compass Automatic laser off : After 90 seconds
Automatic power off : After 180 seconds Safety EMC : IEC Standard No. 61010-1:2001; EN60825-1:2007 Class II ; EN
55022:2010 ; EN 61000-4-3:2010 ;
EN 61000-4-8:2010IP54 distance meter for indoor and limited outdoor application with bright laser and inclination sensor,
phythagoras calculation, tripod mode, storage for quick recall of distance, compass and automated endpiece correction.
Range at Leica target plate GZM26 : 100 m330 ft Typical range : 80 m260 ft
Typical measuring tolerance : ± 1.0 mm Smallest unit displayed : 1 mm 132 in
Measuring tolerance to laser beam to housing : ± 0.2° Tilt measurement range : 360°
88
SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011.
Calibration cycle : Tilt and compass Automatic laser off : After 90 seconds
Automatic power off : After 180 seconds Safety EMC : IEC Standard No. 61010-1:2001; EN60825-1:2007 Class II ; EN
55022:2010 ; EN 61000-4-3:2010 ; EN 61000-4-8:2010 Infrared thermometer with 3-simple button, quickly navigate to emissivity, start data
logging, or turn on and off alarms,
also can be used to measure with contact probe. Infrared temperature range : -40 °C to 800 °C ; Infrared accuracy : Up to ± 1 or ±
1.0 °C ; Display resolution : 0.1 °C 0.1 °F Thermocouple Type-K input temperature range : -270 °C to 1372 °C -454 °F to 2501
°F ; Thermocouple Type-K input accuracy : Up to ± 1 or ± 1.0 °C
Distance to measurement spot size : 50 : 1 Laser sighting : Single-point laser 1 mw output Class 2 II operation, 630 nm to 670
nm Emissivity adjustment : By built-in table of common materials or digitally adjustable from
0.10 to 1.00 by 0.01 Data storage with DateTime stamp : 99 points ; PC Interface and cable : USB 2.0 with
software Power : 2 AALR6 Batteries and USB when used with a PC
Other features : Measure minmaxavgdif, two levels backlight, has trigger lock, dot matrix 98 x 96 pixels with function menus,
measure temperature for pipes with 6.4 mm to 64 mm diameter and 3.8 cm to 14 cm diameter , 1 m lead wire, range -29 °C to149 °C.
Rugged and precision pressure gauge to measure pneumatic and hydraulic pressure, including test pump for a complete pressure testing
and calibration solution. Tools come with a tool bag. Pressure range : -12 to 300 psi for pneumatic and -14 to 10000 psi for hydraulic ;
Accuracy : Positive pressure ±0.05 FS ; Vacuum ±0.1 FS ; Resolution : Up to 0.01 psi for pneumatic and 1 psi for hydraulic
Pressure connection : ¼ in NPT Male, 14 in NPT to ¼ ISO adapter provided Display : 5-12 digits, 16.53 mm 0.65 in high 20 –segment ar graph, 0 to 100
Battery life : 1,500 hours without backlight continuous on, 2,000 hours at slow sample rate
Safety : CSA: Class 1, Div2, Groups A-D rating ; ATEX: rating II 3 G Ex nA IIB T6 Other features : Data can be stored and logged to PC with logging software, gauges
with protective holster, software can be used to download logging configurations for a remote logging event, configure logging event
reading rate, duration and measurement units, pumps can generate pressure up to 600 psi and 10,000 psi, come with hoses, adapters,
and hardcase.
2 Must have Supporting letter from principal and supporting letter from local support
Distributor in indonesia
89
SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011.
d. Specific measuring device for conformance portable electricalsafety equipment