89
SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011.
d. Specific measuring device for conformance portable electricalsafety equipment
1 Portable appliance tester with redefined auto test capabilities, has pre-set passfail
levels to save time, single mains socket for appliance connection, separate IEC socket for easy mainsextension lead testing, detachable test leads for quick field replacement,
has integral carrying handle, memory review facility, integral QWERTY keyboard, compact flash card receptacle, large backlit graphics displays, able to download to PC,
passfail level programmable indicators, data storage, polarity checks, programme mode, real time clock, IEC lead test, auto-testing, graphical help menu on line.
Measurement functions : L N main volts, outside limits indicators, null out facility for earth bond lead, protective earth resistance PE 250 mA, protective earth resistance
PE 25A, insulation 500V DC, protective earth conductor current, touch current, substitute leakage current, appliance power kVA, appliance load current. Power-on Test
: The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. Display range: 90 V to 264 V ; accuracy at 50 Hz: ± 2 + 3 counts ;
resolution: 0.1 V 1 V - model 6200 ; input impedance 1 MΩ 2.2 nF ; maximum input mains voltage: 300 V Earth Bond Test Rpe : display range: 0 to 19.99 Ω ;
accuracy after Bond Test zeroing: ± 2.5 + 4 counts ; resolution: 0.01 Ω ; test current: 200 mA AC -0 +40 into 1.99 Ω ; 25 A AC ± 20 into 25 mΩ at 230 V ;
open circuit voltage: 4 V AC, 24 V AC ; bond test zeroing: can subtract up to 1.99 Ω Insulation Test Riso : display range: 0 to 299 MΩ ; accuracy: ± 5 + 2 counts
from 0.1 to 300 MΩ ; resolution: 0.01 MΩ 0 to 19.99 MΩ ; 0.1 MΩ 20 to 199.9 MΩ ; 1 MΩ 200 to 299 MΩ ; test voltage: 500 V DC -0 + 10 at 500 kΩ load ; test
current: 1 mA at 500 kΩ load, 15 mA at 0 Ω ; auto discharge time: 0.5 s for 1 μ F ; max. capacitiveload: operational up to 1 μ F. Touch Current Test : display range: 0 to
1.99 mA AC ; accuracy: ± 4 + 2 counts ; resolution: 0.01 mA ; internal resistance via probe: 2 kΩ ; measuring method: probe. Substitute Leakage Current Test Display
range: 0 to 19.99 mA AC ; accuracy: ± 2.5 + 3 counts ; resolution: 0.01 mA ; test voltage: 35 V AC ± 20 LoadLeakage Test: Load Current : Display range: 0 to 13 A ;
accuracy: ± 4 + 2 counts ; resolution: 0.1 A LoadLeakage Test: Load Power : Display range: 0 to 999 VA ; 1.0 kVA to 3.2 kVA ; accuracy: ± 5 + 3 counts ;
resolution: 1 VA 0 to 999 VA ; 0.1 kVA 1.0 kVA to 3.2 kVA LoadLeakage Test: Leakage Current Display range: 0 to 19.99 mA ; accuracy: ± 4 + 4 counts ;
resolution: 0.01 mA PELV Test Accuracy at 50 Hz: ± 2 + 3 counts ; overload protection: 300 Vrms ; warning threshold: 25 Vrms. Safety Rating : EN61010-1 CAT II,
300 V Include : Test lead, test probe, crocodile clip, mains cord, carrying case.
2 Must have Supporting letter from principal and supporting letter from local support
Distributor in indonesia
e. Calibration device for general purpose product
1 Calibrator for many products : analog meters, up to 4.5 digits digital multimeters, clamp
meters, oscilloscope, panel meters, watt meters, megohm meters, etc, has high voltage and current compliance, has built-in protection circuitry protects, can collect and report
calibration data, including hard carrying case. Maximum burden or compliance voltage : 600 mA dc voltage, 800 mA ac voltage, 50V dc current, 44V ac current Range : 0
mV to 1020.00 V dc ; 0 µA to 20.500 A dc ; 1.00 mV to 1020.0 V ac ; 29.0 µA to 20.500
90
SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011.
A ac ; 0 Ω to 190 MΩ resistance ; 10 kΩ to 10 GΩ , plus 18 GΩ single value with 0 to 1575 Vdc peak for meg Ohm insulation resistance ; 1Ω to 5.9 kΩ 16 values with
current 700 mA max for continuity ; 50 kHz to 200 MHz leveled sinewave ; 5 s to 2 ns time markers ; ± 1.8 mV to ± 2.2 V p-p 50 Ω and ± 1.8 mV to ± 105 V p-p 1 MΩ for
AC voltage squarewave ; 4.5 mV to 2.75 V p-p 50 Ω for fast edge Accuracy : up to 0.01 + 15 for DC Voltage 0V to 3.29999 V ; up to 0.05 + 1.25
for DC current 0 mA to 32.999 mA ; up to 0.10 + 180 for AC voltage sine wave 0.33V to 3.2999 V ; up to 0.10 + 12 for AC current sine wave 3.3 mA to 32.999 mA
; 0.025 for resistance 1000 Ω , 1.9k Ω , 10k Ω ; 0.11 for DC power 3.3mA to 329.99mA with 33 mV to 1010 V ; 0.36 for AC power 9 mA to 32.999 mA with 330
mV to 1020V, 45 Hz to 65 Hz ; 0.49 for AC power 2.2 A to 4.499 A with 330mV to 1020 V ; 0.0050 ± 2 mHz for frequency 45.00 Hz to 1000.0 Hz ; 0.20 for
megOhm insulation resistance tester ; 0.1 for resistane continuity ; up to 0.35 for oscilloscope DC voltage and AC voltage squarewave. Resolution : up to 1 µV DC
voltage ; up to 10 nA DC current ; 10µV AC voltage sine wave ; 0.01 Hz frequency. Power consumption : 600 VA. Safety : Meets EN 61010-1:2001,
CANCSA-C22.2 No. 61010-1-04, UL 61010-1:2004. Other features : Including 1050 turn coils, has transit case with wheels, software to remotely control the calibrator,
manage inventory, collect data and print customized reports. 2
Must have Supporting letter from principal and supporting letter from local support Distributor in indonesia
f. System for environmental conformance measurement