Measuring device and analyzer for network cabling and fiber optic

78 SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011.

h. Measuring device and analyzer for network cabling and fiber optic

1 LAN Cable Testers SPECIFICATION a General Specification • Modular design supports copper certification, fiber loss, OTDR testing • Unmatched speed for Cat 6A, Class FA and all current standards • Have ability to system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed • Touch screen user interface simplifies set-up, and eliminates • Have a management software to Analyze test results and create professional test reports • Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting • ETL Verified to IEC Level V – the most stringent accuracy requirement • Endorsed by cabling vendors worldwide • Built in Alien Crosstalk testing capability b Technical Specification • Level V accuracy : Specified to 1 GHz • Resistance Unbalance measurement : Supports IEEE 802.3af and IEEE 802.3at PoE operation that Found in TIA, ISO and IEEE standards • TCL and ELTCTL balance measurements : Good balance means better immunity to external noise, Found in TIA and ISO standards and Critical in noise environments • Shield effectiveness test : Grounded racks in data centers can cause a false Wire Map PASS, If the shield is open, the Wire Map tester may still report a PASS – not DSX, then show Distance to open shield • Built in Project Management : Configure multiple setups in advance to Prevents errors such as incorrect test limits and Export setups to tester via USB or thumb drive • Built in Alien Crosstalk measurement : Critical for supporting 10GBASE-T in data centers which is Specified in ISO and TIA standards • CDNEXT measurement : Common mode to Differential mode near end crosstalk measurement and Diagnostic tool for Alien Crosstalk issues • Store over 10,000 test results : Category 6AClass EA with full plot data and diagnostic data • NEXT and Return Loss diagnostics : HDTDR to locate impedance anomalies – must be able to store and export with result and HDTDX to locate crosstalk issues - must be able to store and export with result • Results management : Includes statistical analysis with Built in PDF export 2 OTDR Fiber Optic Test Kit SPECIFICATION a General Specification 1 Fastest time to certify – two fibers at two wavelengths in three seconds. 2 Have Encircled Flux compliant as required by ANSITIA and ISOIEC with no additional test cords 3 Merged Tier 1 Basic Tier 2 Extended testing and reporting when paired with OTDR 4 Convenient quad module supports both multimode and singlemode loss testing 5 Extended singlemode distance range to 130km 6 The OTDR is the Industry’s shortest event and attenuation dead zones 79 SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011. 7 Accelerate fiber certification with the fastest set-up and trace times 8 Improve resource utilization with custom configurations for projects and users 9 Simplify use with Data Center OTDR mode and Event Map view b Technical Specification 1 Encircled Flux compliant : Source must be EF compliant, Matched test reference cords per TIA TSB-4979 and Required in ANSITIA-526-14-B and IEC 61280-4-2. 2 3 second Autotest:  Multimode at 850 nm and 1300 nm on two fibers  Singlemode at 1310 nm and 1550 nm on two fibers 3 1 Jumper reference for SC, LC, ST and FC connectors : Required for cabling warranty application and Requires interchangeable adapters on the input ports 4 Test reference cord verification : Built in wizard guides users through the reference procedure Includes a step to verify TRCs TRC verification results stored automatically 5 Built in Visual Fault Locator : Locate bends and cracks in fiber rackstrays and also Verify polarity 6 Quad fiber modul : • Dual output ports for 8501300 nm and 13101550 nm • Single input port calibrated for 850 nm, 1300 nm, 1310 nm and 1550 nm 7 Store two fiber results at once : Remote results automatically sent to main unit for analysis and storage 8 Fiber Inspection : Allows the attachment of a USB camera, Store results internally and Merges fiber inspection results with Tier 1 and Tier 2 results 9 Extended distance: • 12 km for multimode • 130 km for singlemode 10 Built in talk set: Full duplex communication over multimode and singlemode links 11 Results management : Statistical analysis, Merger OLTS, OTDR and fiber inspection results with Built in PDF export c Must have Supporting letter from principal and supporting letter from local support Distributor in indonesia

i. Specific measuring devices wired LAN Network