Server Farm switch – 2 units Wall mount Rack 15U – 13 units UPS wallmount Rack – 13 units

15 SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011. 4 128 Gbps switching capacity use 5 2 and Layer 3 throughput : 95Mbps 6 Layer 2 features : 7 Maximum MAC addresses per system : 16,000 8 Jumbo frames : 9.216 Bytes 9 Number of VLANs : 4,096 10 Range of possible VLAN IDs : 1 to 4.095 11 2 pieces of 10 GbE SFP optic Ethernet 850nm with a maximum transmission distance of 300 m 12 Having a management roll-back feature that serves to restore the configuration to a previous configuration 13 Operating System is modular Scalable 14 Letters of support and after-sales from principle 15 security gateways , core switches , distribution switches , and access switches 1 brand for easy after-sales service , compatibility and interoperability 16 brochure

d. Server Farm switch – 2 units

Server Farm switch must have a minimum specification: 1 24-port 101001000BASE-T 2 Fix 4 - port uplinks can config as port GbE SFP or 10GbE SFP + 3 DRAM: 1 GB ECC, 1 GB Flash, CPU 1Ghz 4 Use 88 Gbps switching capacity 5 Use 88 Gbps switching capacity 6 Layer 2 features : 7 Maximum MAC addresses per system : 32,000 8 Jumbo frames : 9.216 Bytes 9 Number of VLANs : 4,096 10 Range of possible VLAN IDs: 1-4,095 11 Uplink Module 2 - Port 10G SFP + 4 - port 1G SFP 12 2 pieces of 10 GbE SFP optical Ethernet transmission 850nm with a maximum distance of 300m 13 Having a management roll-back feature that serves to restore the configuration to a previous configuration 14 Operating System is modular Scalable 15 Letters of support and after-sales from principle 16 security gateways , core switches , distribution switches , and access switches 1 brand for easy after-sales service , compatibility and interoperability

e. Wall mount Rack 15U – 13 units

Wall mount Rack 15U must have a minimum specification: 1 Wall mounted Rack 15U Depth 600mm Double Door 2 includes : 3 1 Units Glass front Door 4 1 Units Back Metal Door 5 2 Units Side Panel 6 1 Units Single Fans 7 1 unit Horizontal Power Distributions 6 Outlets 8 20 Unit Cage Nuts 16 SPEKTEK ALAT LABORATORIUM PENGEMBANGAN INDUSTRI TEKNOLOGI KEPOLISIAN KSA T.A. 2011. 9 4 Unit Dynabolt 10 2 unit wiring management 11 Broshur

f. UPS wallmount Rack – 13 units

UPS must have a minimum specification: 1 input connections using IEC - 320 C14 2 Output connection using IEC - 320 C13 x 6 3 Communication interface using USB , terminal blocks , Intellislot 4 Rack Tower Convertible , including Tower Stand 5 The battery can expand 6 Shutdown monitoring software can be installed on Windows NT2000XPVista , Linux9 7 LED Display 8 Capacity 1500VA 1350watt 9 Power factor 0.9 10 Input Voltage 177 - 280VAC 100 load , 115 - 280VAC 30 Load 11 Input Frequency 40-70Hz 12 Input Protection Type Resettable Circuit Breaker 13 Frequency 50Hz 14 Efficiency of 90 on Line Mode 15 Output can be adjusted in battery mode 220230240VAC 16 Voltage regulation : ± 3 17 Wave Form Pure Sine Wave 18 Battery Type Sealed , non - spillage , maintenance-free , lead acid with 5 year life time 19 backup time at full load 4 Minutes 20 Recharge time 3 hours to 90 of the specified capacity , after full discharge into resistive load 21 Hot swappable battery 22 Operating Conditions 3,000 meters max. Elevation, 0-90 humidity non - condensing, 0-40 deg . C 23 The noise level is 45 dBA on Line Mode 24 Online Thermal Dissipation 25 Accessories 26 Supporting SNMP WEB Management Card 27 Supports battery cabinet Extend yes 28 Supporting Service Bypass panel 29 rack mount kit 30 Letters of support and after-sales from principle 31 Letter from the principal availability of spare parts for min. 5 years 32 entire UPS 1 brand for easy after-sales service

3. LIBRARY