Heater IV Mixer II M-02 Heatet V H-05 Kolom Destilasi I MD-01 Heater VI H-06 Mixer III M-03 Cooler III C-03 Reaktor Epoksidasi CRV-02

4.8 Heater III H-03

Tabel 4.8 Neraca Energi pada Heater III H-03 Neraca Energi Heater III H-03 Masuk kJ Keluar kJ ∆H14 -25799507,8206 ∆H15 -25799507,8206 Total -25799507,8206 Total -25799507,8206

4.9 Flash Drum II FD-02

Tabel 4.9 Neraca Energi pada Flash Drum II FD-02 Neraca Panas Flash Drum II FD-02 Masuk kJ Keluar kJ ΔH16 -568827622,0579 ΔH17 -249710694,5096 ΔH18 -319116927,5483 Total -568827622,0579 Total -568827622,0579

4.10 Heater IV

H-04 Tabel 4.10 Neraca Energi pada Heater IV H-04 Neraca Energi Heater IV H-04 Masuk kJ Keluar kJ ∆H15 -25799507,8206 ∆H19 -122857357,3206 dQdt -97057849,5000 Total -122857357,3206 Total -122857357,3206

4.11 Mixer II M-02

Tabel 4.11 Neraca Energi pada Mixer II M-02 Neraca Panas Mixer II M-02 Masuk kJ Keluar kJ ΔH18 -319116927,5483 ΔH20 -441974284,8689 ΔH19 -122857357,3206 Total -441974284,8689 Total -441974284,8689 Universitas Sumatera Utara

4.12 Heatet V H-05

Tabel 4.12 Neraca Energi pada Heater IV H-04 Neraca Energi Heater V H-05 Masuk kJ Keluar kJ ∆H20 -441974284,8689 ∆H21 -379446072,398783 dQdt 62528212,4701 Total -379446072,3988 Total -379446072,3988

4.13 Kolom Destilasi I MD-01

Tabel 4.13 Neraca Energi pada Kolom Destilasi I MD-101 Neraca Panas Kolom Distilasi I MD-01 Masuk kJ Keluar kJ ∆H11 -574838059,2744 ∆H12 -164765909,5449 ∆H8 200228974,2089 ∆H13 627113598,0006 Qr 55178866,1993 Qc 71991340,2615 Total -719888167,2840 Total -719888167,2840

4.14 Heater VI H-06

Tabel 4.14 Neraca Energi pada Heater VI H-06 Neraca Energi Heater VI H-06 Masuk kJ Keluar kJ ∆H13 -627113598,0006 ∆H23 -519932337,6577 dQdt 107181260,3429 Total -519932337,6577 Total -519932337,6577

4.15 Mixer III M-03

Tabel 4.15 Neraca Energi pada Mixer III M-03 Neraca Energi Mixer III M-03 Masuk kJ Keluar kJ ΔH23 -500335962,7680 ΔH25 -2517138068,7799 ΔH24 9657027,7365 ΔH39 -2026459133,7484 Total -2517138068,7799 Total -2517138068,7799 Universitas Sumatera Utara

4.16 Cooler III C-03

Tabel 4.16 Neraca Energi pada Cooler III C-03 Neraca Panas Cooler III C-03 Masuk kJ Keluar kJ ∆H26 -2517138068,7799 ∆H27 -2766047361,5088 dQdt 248909292,7289 Total -2517138068,7799 Total -2517138068,7799

4.17 Reaktor Epoksidasi CRV-02

Tabel 4.17 Neraca Energi pada Reaktor Epoksidasi CRV-02 Neraca Panas Reaktor Epoksidasi CRV-02 Masuk kJ Keluar kJ ΔH27 -2766047361,5088 ΔH28 -2930364193,4680 ΔH rx -328633663,9183 dQdt -164316831,9592 Total -3094681025,4271 Total -3094681025,4271

4.18 Cooler IV C-04