Pemilihan penampang Asumsikan bahwa = 0, lalu modulus penampang minimum diserat bawah Analisis Penampang

Momen maksimum ditengah bentang : `v = ~ × 1,4 w• , = ~ × 1,4 × 416.64941 kgm J18,0 K , = 23624.02 kgm

IV.1.2. Pemilihan penampang Asumsikan bahwa = 0, lalu modulus penampang minimum diserat bawah

agar penampangnya efisien dihitung dengan rumus : ≥ J1 − K v + `v + 8 − ≥ J1 − 0,79K 67495.68 … + 23624.02 … + 20985.48 … 0 − 0,79J−1551375K … , ≥ 58783.5928 … 1225586,25 … , ≥ 0.0479637 ‡ ≥ 47963.654 { ‡ Berdasarkan hasil perhitungan diperoleh nilai = 47963.654 cm 3 , maka dipilih profil penampang PCI 12LDT34 Pretopped Double Tee dengan nilai : = 3340 ˆ ‡ = 54732,79 cm 3 Gbr.4.2 Profil Penampang PCI 12LDT34 Pretopped Double Tee Universitas Sumatera Utara Data profil PCI 12LDT34 Pretopped Double Tee : = 978 ˆ , = 0,6309 m 2 ‰ = 86072 ˆ Š = 0,03582 m 4 ‹ , = 1 I ; I = ~ Œ, • ŽŒ~ = = 88,0 in 2 = 0,0567 m 2 = 10458 in 3 = 0,17137 m 3 = 3340 in 3 = 0,054732 m 3 { = 8,23 in = 0,209 m { = 25,77 in = 0,6545 m v = 781 Plf = 1162,128 kgm VS = 1,41 in = 0,035814 cm

IV.1.3. Analisis Penampang

Profil direncanakan menggunakan tendon dengan spesifikasi : = 270000 Psi = 1861,65 MPa = 186165000 kgm 2 Untuk penampang standar digunakan strand pattern 128-D1 12 strand berdiameter ½ in = 12 × 0,153 inch 2 = 1,836 inch 2 = 0,0011845 m 2

IV.1.3.1. Analisis Penampang Pada Saat Transfer :

v = 67495.68 … × ,,,~ Ž .Š = 65892.658 kgm Universitas Sumatera Utara = 0,70 = 0,70 × 270000 Psi = 189000 Psi = 1303,155 MPa = 130315500 kgm 2 = × = 0,0011845 m 2 × 130315500 kgm 2 = 154360,5029 kg ► Penampang Tengah Bentang d = 22,52 ˆ {ℎ = 0,572 Serat Atas = − 5 ; I \1 − P I × • G = _ − A ` G ≤ = − ’Š‡ ,’ ,Ž QX ,‡ Ž = \1 − ,’Œ, × ,, Ž , ’Œ = _ − ’~Ž,.’~ QX“ ,Œ‡Œ 9 ≤ = −244640,003 … , J−1,10594K − 384491.94 … , ≤ = −113934.2 … , ≤ = 253338,476 … , ……………………OK Serat Bawah = − 5 ; I \1 + P I × • b = _ + A ` b ≤ = − ’Š‡ ,’ ,Ž QX ,‡ Ž = \1 + ,’Œ, × ,’Š’ , ’Œ = _ + ’~Ž,.’~ QX“ , ’ŠŒ‡, 9 ≤ = −244640,003 … , J7,594164K +1203897.2 … , ≤ = −653949.5 … , ≤ = 1551375 … , ……………………OK Universitas Sumatera Utara ► Penampang tumpuan d P = 14,10 ˆ {ℎ = 0,35814 Serat Atas = − 5 ; I \1 − P L × • G = _ − 0 ≤ = − ’Š‡ ,’ ,Ž QX ,‡ Ž = \1 − ,‡’~Š × ,, Ž , ’Œ = _ − 0 ≤ = −244640,003 … , J−0,31855K − 0 ≤ = 77929.992 … , ≤ = 253338,476 … , ……………………OK Serat Bawah = − 5 ; I \1 + P L × • b = _ + 0 ≤ = − ’Š‡ ,’ ,Ž QX ,‡ Ž = \1 + ,‡’~Š × ,’Š’ , ’Œ = _ + 0 ≤ = −244640,003 … , J5,128673K + 0 ≤ = −1256092,239 … , ≤ = 1551375 … , ……………………OK IV.1.3.2. Analisis Penampang Pada Saat Final : ” = • = v + `v + 8 = 65892.658 … + 23624.02 … + 20985.48 … = 110502.16 kgm Universitas Sumatera Utara P = = 0,79 × 189000 Psi = 149310 Psi = 102949245 kgm 2 P = × P = 0,0011845 m 2 × 102949245 kgm 2 = 121943,381 kg ► Penampang Tengah Bentang d = 22,52 ˆ {ℎ = 0,572 Serat Atas = − 5 L ; I \1 − P I × • G = _ − – ` G ≤ = − ,ŽŠ‡,‡~ QX ,‡ Ž = \1 − ,’Œ, × ,, Ž , ’Œ = _ − ’ ,. QX“ ,Œ‡Œ 9 ≤ = −193284,8011 … , J−1,10594K − 644793.98 … , ≤ = −431053.4 … , ≤ = 2068500 … , ……………………OK Serat Bawah = − 5 L ; I \1 + P I × • b = _ + – ` b ≤ = − ,ŽŠ‡,‡~ QX ,‡ Ž = \1 + ,’Œ, × ,’Š’ , ’Œ = _ + ’ ,. QX“ , ’ŠŒ‡, 9 ≤ = −193284,8011 … , J7,594164K +2018938.8 … , ≤ z 551239.83 … , ≤ = 585060,1508 … , ……………………OK Universitas Sumatera Utara ► Penampang tumpuan d P = 14,10 ˆ {ℎ = 0,35814 Serat Atas = − 5 L ; I \1 − P L × • G = _ − 0 ≤ = − ,ŽŠ‡,‡~ QX ,‡ Ž = \1 − ,‡’~Š × ,, Ž , ’Œ = _ − 0 ≤ = −193284,8011 … , J−0,31855K − 0 ≤ = 61570,873 , ≤ = 585060,1508 … , ……………………OK Serat Bawah = − 5 L ; I \1 + P L × • b = _ + 0 ≤ = − ,ŽŠ‡,‡~ QX ,‡ Ž = \1 + ,‡’~Š × ,’Š’ , ’Œ = _ + 0 ≤ = −193284,8011 … , J5,18673K + 0 ≤ = −1002516,076 … , ≤ = 2068500 … , ……………………OK Dari analisa tegangan yang dilakukan pada penampang di tumpuan dan ditengah bentang baik pada saat transfer maupun pada kondisi beban kerja transfer, diperoleh bahwa tegangan diserat atas dan diserat bawah penampang lebih kecil daripada tegangan izin maksimumnya, maka penampang dapat dikatakan aman atau telah sesuai untuk digunakan. Universitas Sumatera Utara

IV.1.4. Kehilangan Prategang Losses