Untuk Gelagar Tepi HASIL DAN PEMBAHASAN

Tegangan akibat momen σ = � � = 76 .729 0.00003 = 225.765 kg �� 2 ˃ σ izin NOT OK Tegangan akibat lintang = 3 ���� 2 �ℎ = 3 � 225.675 2 �0.05�0.06 = 11.284 kg �� 2 ˂ 0.2x100 kg�� 2 OK

b.Untuk Gelagar Tepi

Berat sendiri = luas tampang x b.j kayu = 0.06 x 0.05 x 800 = 2.4 kgm Beban deck = beban lantai lebar lantai = 12.6 0.2 = 63 kgm catatan beban lantai = RA = RC Q Total = 65.4 kgm Mmax = MB = 1 8 �� 2 = 1 8 � 65.4 � 1.7 2 = 23.626 kgm RA = RC = 1 2 �� − � � = 1 2 � 65.4 � 1.7 − 23.626 1.7 = 41.692 kg RB = �� + 2� � � = 65.4 � 1.7 + 2 � 23.626 1.7 = 138.975 kg Dmax = 1 2 RB = 1 2 138.975 kg = 69.488 kg W = 1 6 �ℎ 2 = 1 6 0.05 �0.06 2 = 0.00003 � 2 Universitas Sumatera Utara Tegangan akibat momen σ = � � = 23.626 0.00003 = 78.753 kg �� 2 ˂ σ izin OK Tegangan akibat lintang = 3 ���� 2 �ℎ = 3 � 69.488 2 �0.05�0.06 = 3.474 kg �� 2 ˂ 0.2x100 kg�� 2 OK 4.10.4 Evaluasi Gelagar Melintang Ukuran gelagar melintang Panjang gelagar melintang = 1.5 meter Lebar = 0.05 meter Tinggi = 0.06 meter Jarak antar gelagar memanjang = 0.40 meter RA = RB = ½ ql + p1 + p2 + p3 + p4 = ½ 2.4 x 1.5 + 138.975 + 451.35 + 451.35 + 138.975 = 592.575 kg Mmax = �� � 0.75 − 1 2 . � � 0.75 2 − �1 � 0.6 − �2 � 0.2 = 592.575 x 0.75 - 1 8 . 2.4 � 1.5 2 - 138.975 x 0.6 – 451.35 x 0.2 = 297.728 kgm Wx = 16 bh = 16 x 0.05 x 0.06 = 0.00003 m 2 Tegangan akibat momen = ���� � 2 = 297 .728 0.00003 = 992.425 kg �� 2 ˂ σ izin NOT OK 4.10.5 Evaluasi Kabel Hanger Universitas Sumatera Utara Diameter kabel hanger = 15 mm Tegangan izin kabel hanger = 1600 kg �� 2 Beban yang diterima hanger = 602.0013 kg Daya dukung hanger = tegangan izin hanger x luasan tampang = 1600 x ¼ x 3.14 x 1.5 = 2826 kg 2 Faktor keamanan = daya dukung hanger beban yang diterima = 2826 602 .0013 = 4.694 OK 4.10.6 Evaluasi Kabel Utama Jembatan Panjang bentang jembatan = 60 meter Diameter kabel utama = 30 – 3 = 27 mm d = 2.3 meter Pembebanan yang diterima oleh kabel utama : Deck jembatan = luas tampang memanjang deck x Bj. kayu = 0.025 x 1.38 x 800 = 27.6 kgm Gelagar memanjang 4 buah gelagar = 4 x berat sendiri gelagar memanjang = 4 x 0.05 x 0.06 x 800 = 9.6 kgm Gelagar melintang = n gelagar x w gelagar x l gelagar melintang L jembatan = 33 x 0.05 x 0.06 x 800 x 1.4860 = 2.10 kgm Universitas Sumatera Utara Gelagar penahan lateral = n gelagar x w gelagar x l gelagar melintang L jembatan = 34 x 0.05 x 0.06 x 800 x 2.2760 = 2.64 kgm Hanger = 2.124 kgm Kabel utama = 9.016 kgm Beban tambahan = diasumsikan = 2 kgm Beban mati = total keseluruhan = 27.6+ 9.6 + 2.10 + 2.64 + 2.124 + 9.016 + 2 = 57.905 kgm Beban hidup simetris = beban hidup x lebar jembatan = 400 x 1.38 = 552 kgm Beban hidup asimetris = ½ x beban hidup simetris = ½ x 552 = 276 kgm Akibat beban hidup merata penuh q s = 552 x 60 2 8 � 2.3 = 108000 kg = beban hidup simetris x � 2 8d Akibat beban hidup tidak simetris di tengah bentang q as = beban hidup asimetris x � 2 8d = 276 x 60 2 8 � 2.3 = 54000 kg Akibat beban mati q d = beban mati x � 2 8d Universitas Sumatera Utara = 57.905 x 60 2 8 � 2.3 = 11329.34 kg Gaya H = maximum antara q s + q d , q as + q d = diambil = q s + q d = 108000+ 11329.34 = 120894.60 kg Sudut kabel utama α = arc tan 4dL = arc tan 4 � 2.3 60 = 0.152148 rad = 8.717457 Gaya kabel utama T = � ��� � = 120894 .60 ��� 8.717457 = 122307.5 kg Untuk 1 kabel T 1 = T2 = 122307.52 = 61153.74 kg Daya dukung kabel utama = tegangan izin kabel x luasan tampang = 0.67 x 15000 x ¼ x 3.14 x 0.027 = 57512.63 kg 2 Faktor keamanan = daya dukung kabel uatama beban diterima = 57512.6361153.74 = 1.161 NOT OK 4.10.7 Evaluasi Kabel Backstay Sudut kabel backstays ϕ = arc tan ������ ������ ������� ������� ���� Universitas Sumatera Utara = arc tan 3 3 = 0.785398 rad = 45 Gaya H = 120894.60 kg Gaya kabel backstays T = � ��� � = 120894 .60 ��� 45 = 170970.7 kg Untuk 1 kabel T 1 = ½ x 170970.7 = 85485.36 kg = ½ x T Daya dukung backstay = tegangan izin kabel x luasan tampang = 0.67 x 15000 x ¼ x 3.14 x 0.027 = 87512.63 kg 2 Faktor keamanan = daya dukung backstay beban yang diterima = 87512.63 85485.36 = 1.347 NOT OK 4.10.8 Evaluasi Lendutan Yang Terjadi Momen Inersia Gelagar Pengaku =112 bh 3 x 4 cm 4 = 112 x 5 x 6 3 = 360 cm x 4 Modulus Elastisitas E : 125.000 kgcm 4 Panjang bentang jembatan L = 6000 cm 2 Beban hidup merata q = 5.52 kgcm Beban sendiri struktur w = 0.579 kgcm Universitas Sumatera Utara Lendutan gelagar pengaku pada ¼ bentang ≡ lendutan kabel pada ¼ bentang 51 −��� 4 12288 �� ≡ �� � 8 �� �+ � � 2  51 −0.99935.52 � 6000 4 12288 � 125000 � 360 = 48.281 �� Lendutan Pada ¼ Bentang : ∆` = �� � 8 �� �+ � � 2 = 0.9993 x � 5.52 8 � � 230 0.579 + 0,9993 x 5.52 2 = 49,461 cm Syarat lendut am maksimum yang terjadi ialah ∆ max “Karena lendutan yang terjadi ialah sebesar 49,461 cm 60 cm, maka masih memenuhi syarat lendutan maksimum jembatan gantung”. = �.�������� 100 = 6000 100 = 60 cm Momen Gelagar Pengaku M MAX Tegangan pada gelagar pengaku σ = 1 −��� 2 64 = 1 −0,9993 � 5.52 � 6000 2 64 = 2205 kgcm max = � �� = 2173 .5 30 = 73.5 kgcm 2  OK 4.10.9 Evaluasi Menara Jembatan Dimana disini kekuatan beton diasumsikan menurun menjadi K150. Diamana dianggap sebagai kekuatan yang sudah aus. Maka kekuatan beton ialah : Universitas Sumatera Utara a. Letak garis netral balance untuk regangan berimbang Cb = Xb = d fy . 600 600 + = 204 340 . 400 600 600 = + mm b. Tinggi balok tegangan tekan ekivalen kondisi balance : ab = 1 β .Cb ; untuk fc’= 15 mpa maka 1 β = 0,85 ab = 0,85 .204 = 175 mm c. Kontrol regangan tekan baja : Kontrol Reg. Tekan Baja Xb d Xb x s − = ε ε 003 , . 204 60 204 − = s ε 00212 , = s ε Jadi : → y s ε ε Tul. Tekan leleh sehingga fs’= fy = 400 mpa d. Gaya-gaya dalam : Gaya tarik baja Ts = As.fy = 1963 400.10 -3 Gaya tekan beton = 785.2kN Cc = 0,85 fc’.a.b = 0,85 .15 . 175 .400 .10 = 892,5 kN -3 Gaya tekan baja Universitas Sumatera Utara Cs’ = As’ fy – 0,85 fc’ = 1963 400- 0,85 . 15 = 760,2 kN e. Kapasitas aksial desak Pb = Pnb Pnb = Cc + Cs – Ts = 892,5 + 760,2 – 785.2 = 867.5kN Gaya yang diterima menara ialah, P = H tan φ + H tan θ = 61153.74 tan 45 + 61153.74 tan 8,717 = 70 530,15 kg = 705 KN Maka Pnb P OK f. Momen nominal penampang balance Mnb = x d Ts d x Cs a x Cc − + − +       − 2 x = Garis sumbu penampang = 200 mm a = 175 mm d = 340 mm d’ = 60 mm Mnb = 200 340 2 . 785 60 200 2 , 760 2 175 200 5 , 892 − + − +       − Mnb = 316 762,25 kNmm = 316,76 kNm Universitas Sumatera Utara

4.11 Evaluasi Jembatan Dengan Perangkat Lunak SAP 2000