Analisis berdasarkan luas vertical greenery
44
Tabel 28 Tabulasi hasil uji statistik dengan menggunakan metode analisis Chi-Square untuk penurunan suhu berdasarkan luas vertical greenery pada masing-masing
gedung lanjutan
Penurunan suhu Analisis Luas vertical greenery
Total ≤ 50 m²
50 - 100 m² ≥ 100 m²
Tinggi ≥ 5°C Count
2 1
4 7
Expected Count
1.3 3.5
2.2 7.0
within Penurunan
Suhu 28.6
14.3 57.1
100.0 within
LuasVG 22.2
4.2 26.7
14.6 of Total
4.2 2.1
8.3 14.6
Total Count
9 24
15 48
Expected Count
9.0 24.0
15.0 48.0
within Penurunan
Suhu 18.8
50.0 31.3
100.0 within
LuasVG 100.0
100.0 100.0
100.0 of Total
18.8 50.0
31.3 100.0
Sumber data: pengukuran langsung
Tabel 29 Hasil Uji Chi-Square pengaruh luas pemasangan vertical greenery terhadap penurunan suhu yang dihasilkan
Chi-Square Tests Value
Df Asymp. Sig. 2-sided
Pearson Chi-Square 4.500
a
4 0.343
Likelihood Ratio 4.887
4 0.299
Linear-by-Linear Association 0.048
1 0.827
N of Valid Cases 48
a: 5 cells 55,6 have expected count less than 5. The minimum expected count is 1,31.
Berdasarkan hasil analisis uji Chi-Square, menunjukan bahwa luas vertical greenery
tidak berpengaruh nyata terhadap hasil penurunan suhu. Hal ini terlihat pada hasil simpangan baku dari pearson Chi-square 0.343 lebih besar dari
α 0.05. Berdasarkan tabulasi analisis, pemasangan vertical greenery dengan luas
lebih besar sama dengan 100 m², memiliki persentase terbesar untuk kategori penurunan suhu tinggi
≥ 5°C, yaitu 57.1. Sedangkan untuk kategori rendah ≤ 2°C dan sedang 2 sampai 5°C, persentase terbesar pada pemasangan vertical
greenery dengan luas 50 sampai 100 m², yaitu 57.1 dan 55.
Berikut hasil analisis uji statistik pengukuran peningkatan kelembaban menggunakan uji statistik dengan metode Chi-Square berdasarkan luas
pemasangan vertical greenery. Berikut tabulasi hasil analisis untuk peningkatan kelembaban berdasarkan luas pemasangan vertical greenery ditunjukkan pada
Tabel 30. Sedangkan Tabel 31, menunjukkan hasil analisis Chi-Square pengaruh luas pemasangan vertical greenery terhadap peningkatan persentase kelembaban.
45 Tabel 30 Tabulasi hasil uji statistik dengan menggunakan metode analisis Chi-
Square untuk peningkatan kelembaban berdasarkan luas vertical greenery
pada masing-masing gedung Peningkatan
kelembaban Analisis
Luas vertical greenery Total
≤ 50 m² 50 - 100 m² ≥ 100 m² Rendah
≤ 5 Count
3 9
6 18
Expected Count
3.4 9.0
5.6 18.0
within Peningkatan
kelembaban 16.7
50.0 33.3
100.0 within
LuasVG 33.3
37.5 40.0
37.5 of Total
6.3 18.8
12.5 37.5
Sedang 5 sampai
10 Count
3 12
2 17
Expected Count 3.2
8.5 5.3
17.0 within
Peningkatan kelembaban
17.6 70.6
11.8 100.0
within LuasVG
33.3 50.0
13.3 35.4
of Total 6.3
25.0 4.2
35.4 Tinggi ≥
10 Count
3 3
7 13
Expected Count 2.4
6.5 4.1
13.0 within
Peningkatan kelembaban
23.1 23.1
53.8 100.0
within LuasVG
33.3 12.5
46.7 27.1
of Total 6.3
6.3 14.6
27.1 Total
Count 9
24 15
48 Expected Count
9.0 24.0
15.0 48.0
within Peningkatan
kelembaban 18.8
50.0 31.3
100.0 within
LuasVG 100.0
100.0 100.0
100.0 of Total
18.8 50.0
31.3 100.0
Sumber data: pengukuran langsung
Tabel 31 Hasil Uji Chi-Square untuk peningkatan kelembaban berdasarkan luas pemasangan vertical greenery
Chi-Square Tests Value
Df Asymp. Sig. 2-sided
Pearson Chi-Square 7.723
a
4 0.102
Likelihood Ratio 8.297
4 0.081
Linear-by-Linear Association 0.175
1 0.676
N of Valid Cases 48
a. 4 cells 44,4 have expected count less than 5. The minimum expected count is 2,44 .
46 Berdasarkan hasil analisis uji Chi-Square, menyatakan bahwa luas vertical
greenery tidak berpengaruh nyata terhadap peningkatan kelembaban. Hal ini
ditunjukkan pada hasil simpangan baku dari pearson Chi-Square 0.102 lebih besar dari nilai
α 0.05. Pada tabulasi hasil analisis, menunjukkan peningkatan kelembaban kategori tinggi
≥ 10 m² hasil terbesar terdapat pada luas vertical greenery
lebih besar sama dengan 100 m², yaitu sebesar 53.8.