Intercoolerstage 1 Kompresor stage 2 Desain Pendingin

A-135 = 303 14 3.74166 1,34 −1 1,34 = 423.494 K = 150.494 o C Kerja kompresor: Ws = k k − 1 RxT 1 BM P 2 P 1 k −1 k − 1 = 1,34 1,34 − 1 8,34 303 28,84 3.74166 1 1,34 −1 1,34 − 1 = 1.369 kJkg Efisiensi kompresor = 85 Power kompresor: P = Ws x m η = 1.369kJkg x 5.27621 kgs 0,85 = 8.49783 kW = 11.3871 Hp Efisiensi motor = 90 Motor kompresor, BHP: A-136 BHP = P η = 11.3871 0,9 = 12.6523 HP Sehingga digunakan power kompresor = 13 HP Perhitungan panas kompresor stage 2 Tabel 8.6. panas Input stage 2 Komp A B C D T K ∫Cp.dT H KJoule O 2 28,106 -3,68E-06 1,75E-05 -1,07E-08 303 146,9583 36134.3247 N 2 31,15 -1,36E-02 2,68E-05 -1,17E-08 303 145,8873 75905.5637 Total 112039.888 Tabel.8.7. Panas Output stage 2 Komp A B C D T K ∫Cp.dT H KJoule O 2 28,106 -3,68E-06 1,75E-05 -1,07E-08 423.493678 3750.1746 922098.509 N 2 31,15 -1,36E-02 2,68E-05 -1,17E-08 423.493678 3666.2861 1907578.84 Total 2829677.35 Panas kompresi gas + panas input = panas output Panas kompresi gas = panas output – panas input = 2829677.35 – 112039.888 = 2727637 kJ A-137 Tabel 8.7. Panas Stage 2 Komponen masuk, kJ Keluar, Kj O 2 36134.3247 922098.509 N 2 75905.5637 1907578.84 Kompresi 2727637 Total 2829677.35 2829677.35

4. Intercooler stage 2

Gambar 8.4. Skema untuk intercooler stage 2 Panas gas masuk = panas gas keluar kompresor stage 2 = 2829677.35 kJ Tabel 8.8. Panas keluar intercooler stage 2 Komp A B C D T K ∫Cp.dT H KJoule O2 36134,3247 -3,68E-06 1,75E-05 -1,07E-08 303,00 146,9583 335894,816 N2 75905,5637 -1,36E-02 2,68E-05 -1,17E-08 303,00 145,8873 1433594,71 Total 112039.888 t1 = 30 o C = 303K T2 = 45 o C = 318K T2 = 423.493678 K T1 = 303K A-138 Panas yang diserap pendingin = Panas gas keluar – panas gas masuk = 112039.888 – 2829677.35 = -2717637.465 kJ Air pendingin yang digunakan masuk pada suhu 30 o C dan keluar pada 45 o C = 2 − 1 = 2717637.465 kJ 4,186 kJkg. K 318 − 303K = 43281.37386 Kg Tabel 8.9. Panas intercooler stage 2 Komponen masuk, kJ Keluar, Kj O 2 922098.509 335894,816 N 2 1907578.84 1433594,71 pendingin - 112039.888 Total 2829677.35 224079.7769 Tabel.8.10. Spesifikasi Compressor CP-101 A-139 Alat Compressor Kode CP-301 Fungsi Menaikkan tekanan udara sebelum masuk ke reactor RE-201 Bentuk Multi stage compressor Jumlah Stage 2 stage Kondisi Operasi T = 30 o C P = 14,8 atm Power Jumlah 13 hp tiap stage 1 A-140

9. Flash Drum FD-301

Fungsi : Menurunkan tekanan dan memisahkan fasa uap dan fasa cair keluaran reactor Jenis : Tangki silinder vertical Kondisi Operasi :P = 1 atm dan T = 210 o C

A. Neraca Massa Flash Drum FD-301 1. Komposisi Aliran Liquid

Tabel C.9.1 Komposisi aliran liquid Komponen Massa kgjam w i ρ i kgm 3 w i ρ i C8H10 201,3786 0,0259 673,5044 0,000039 CH3COOH 24,1012 0,0031 809,5728 0,000004 HBr 1,5711 0,0002 809,5728 0,000000 CH3COO2Co 0,5036 0,0001 809,5728 0,000000 CH3COO2Mn 0,4407 0,0001 809,5728 0,000000