Neraca panas Menghitung Menghitung Temperatur Kalorik, T Pemilihan Jenis Alat Perpindahan Panas

e. Menghitung Flow Area a

Annulus : D 2 = 2,46912 = 0,2057 ft D 1 = 1,6612 = 0,1382 ft a a = 4 D D 2 1 2 2   Pers.6.3 Kern, 1965 = 0,0182ft 2 Diameter equivalent, De : De = 1 2 1 2 2 D D D  Pers.6.3 Kern, 1965 = 0,167 ft Pipa : D = 1,3812 = 0,115 ft a p = 4 D 2  = 0,01038 ft 2

f. Menghitung Mass Velocity G

Annulus : G a = a a W = 0182 , 1417,12 = 77822,99 lbhr.ft 2 Pipa : G p = p a w = 0,01038 50,6281 = 4876,712 lbh

g. Menghitung Bilangan Reynold Re

Annulus : T avg = 96,8 o F µ = 0,86 cp × 2,42 Kern, Fig. 15 = 2,080 lbjam ft Re a = De.G a µ Pers. 7.3 =16272,77 Pipa : Pada t avg = 572 o F µ = 0,0195cp × 2,42 Kern, Fig. 15 = 0,046 lbjam ft D = 3,06812 = 0,256 ft Kern, Tabel 10 Re p = D.G p µ Pers. 3.6 = 17335,755

h. Menentukan J

H Heat Transfer Factor

i. Menentukan Termal Function

j. Menghitung Outside Film Coefficient h

o dan Inside Film Coefficient h i Annulus: h o = 1230 Btuhr.ft 2 . o F [table 25 Kern, Hal: 164] Pipa: h io = 1500 Btuhr.ft 2 . o F

k. Menghitung Clean Overall Coefficient U

C U C = o io o io h h h h  [Pers. 6.38] = 675,824 Btujam.ft 2 . o F

l. Menghitung Design Overall Coefficient U

D R d = 0,002 hr.ft 2 . o FBtu Kern, Tabel 8 D U 1 = Rd Uc 1  = 002 , 675,824 1  = 0,00347 U D = 287,38 Btuhr.ft 2 . o F

m. Menghitung Luas Permukaan Perpindahan Panas Yang Dibutuhkan

A = t . U Q D  = 11 , 475 38 , 287 30581,7157  = 0,2239 ft 2 a” = 0,435 ft 2 ft Kern, Tabel 11 Panjang pipa : L = a A = 0,5148 ft linier Panjang hairpin = 12, 15, 20 ft Kern, Hal: 103 Diambil L h = 12 ft Hairpin terdiri dari 2 pipa n = 2 , maka jumlah hairpin yang diperlukan : Hairpin = h 2.L L = 12 2 0,2239  = 0,429 = 1 buah Koreksi panjang pipa: L kor = 2.L h x hairpin = 1 x 12 x 2 = 24 ft linier

n. Menghitung Luas Permukaan Perpindahan Yang Tersedia

Sebenarnya A = L kor x a” = 24 x 0,435 = 10,44 ft 2

o. Menghitung Actual Design Overall Coefficient U

Daktual U Daktual = t A. Q  = 118 , 475 36 , 73 30581,715  = 258 Btuhr.ft 2 . o F

p. Menghitung Dirt Factor R

d R d = d c d c U U U U   = 258 85 , 675 258 82 , 675   = 0,00239 hr.ft 2 . o F Btu