D.44 H
v
= 2.706,3 kJkg = 1.163,501 Btulb H
f
= 503,71 kJkg = 216,557 Btulb e
b
= efisiensi boiler = 90                       Tabel 4.8, Urich, 1984:109 F   = nilai kalor bahan bakar
Tabel 6-3, Ulrich, 1984:332 F   = 42 MJm
3
= 42000000 Jkg = 726.420,968 Btulbm
m
f
= Btulb
968 ,
420 .
26 7
90 ,
Btulb 557
, 216
501 ,
163 .
1 lbjam
4 323.767,73
 
= 287,321 lb
m
jam = 468,951 kgjam = 212,712 m³jam = 244,497 literjam
Daya boiler:
5 ,
34 3
, 970
 
f f
h h
m hp
= 34,5
970,3 Btulb
216,557 -
1.163,501 lbjam
468,951 
= 1,327 hp = 2 hp
Kapasitas boiler :
1000
f s
h h
m Q
 
= 306.590,035 Btujam = 323.469,625 kJjam
D.45 Kebutuhan air   = 1,2 × Jumlah steam
= 1,2 x 1648.902 kgjam = 1762,30,498 kgjam
= 1774,98 m
3
jam Heating surface
: 1 hp boiler  = 10 ft
2
Heating surface total  = 10 × hp boiler
= 10 x 1,326 hp = 13,266 ft
2
= 1,232 m
2
Spesifikasi Boiler ditunjukkan pada Tabel D.15.
Tabel D.15 Spesifikasi Boiler
Alat Boiler
Fungsi Menghasilkan low  pressure steam untuk
keperluan proses Tipe
Water tube boiler Jenis Steam
Low pressure satureted steam Heating surface
1,232 m
2
Kapasitas 323.469,625  kJjam
Bahan Bakar Solar
Kebutuhan BBM 0,244  m
3
jam Power
2 hp Jumlah
1 buah
D.46
l. Filter Water Tank TP-404
Fungsi alat   : Untuk menampung air keluaran sand filter
Tipe tangki  : Silinder tegak vertikal dengan dasar datar flat bottom dan atap head berbentuk kerucut conical
Tekanan : 101,15 kPa = 1 atm
Temperatur  : 30
o
C  = 86
o
F
1. Menghitung Volume Tangki
Kebutuhan air proses = Air output sand filter = 40,3448 m
3
jam = 40344,8 kgjam Waktu tinggal = 1 jam
V H
2
O = Jumlah air x Waktu tinggal = 40,3448 m
3
jam x 1 jam = 40,3448 m
3
Safety factor = 20              Peter and Timmerhaus, 1991, Hal:37
Volume tangki = 1,2 x V H
2
O = 1,2 x 40,3448 m
3
= 48,328 m
3
2. Menghitung Diameter dan Tinggi Tangki
Rasio  HD  yang  di  ambil  adalah  rasio  yang  memberikan  luas tangki  yang  paling  kecil.    Berdasarkan  Tabel  4-27,  Ulrich,  1984,
dimana  H
s
D    2.  Berdasarkan  Brownell  and  Young,  untuk  large tank
berlaku : D = 8H3
H = 0,375 D
D.47 V = 14 x π x D
2
x H D = 4V
π x H
0,5
= 32V3μ
0,5
Sehingga diperoleh: D = 11,08 m  =  36,34 ft H = 4,15 m  =  13,63 ft
Nilai standar Brownell and Young, App. E, Item 1, Hal. 346 : D = 40 ft  =  12,19 m = 480 in
H = 12 ft = 3,66 m = 144 in Maka,
Volume tangki = 15,079,645 ft
3
= 427,008 m
3
Diperoleh data Brownell and Young, App. E, Item 2, Hal. 347 : Number of courses
= 2 Lebar plate standar = 6 ft
3. Menghitung Tekanan Desain
P
abs
= P
operasi
+ P
hidrostatis
H
liquid
= V
liquid
V
tangki
x H
tangki
= 427,008 m
3
333,607  m
3
x 3,66 m
= 2,86 m = 9,38 ft = 112,50 in Dimana ρ = 992,8ηθ kgm
3
= 61,982 lbft
3
Dimana, P
hidrostatis
:
P
hidrostatis
=
144
c L
g g
H 
 Pers. 3.17, Brownell, 1959
= 4,035 psi P
operasi
= 14,7 psi
D.48 Maka, P
abs
= 18,735 psi Tekanan  desain  5-10    diatas  tekanan  absolut  Coulson,  1988,
Hal:637.  Tekanan  desain  yang  dipilih  5    diatasnya.  Tekanan desain pada ring ke-1 paling bawah :
P
desain
= 1,05 x 18,735 psi = 19,67 psi Tabel  D.16  Hasil  perhitungan  P
design
pada  berbagai  ketinggian cairan :
Course H
liquid
ft P
hid
psi P
abs
psi P
desain
psi 1
9,375 4,035
18,735 19,67
2 3,375
1,453 16,153
16,96
4. Menentukan Tebal Plate
Keterangan : F = 12.650 Brownell and Young, 1959, Tabel 13.1 untuk T = -20 -
650
o
F E = 0,8 Jenis sambungan las : single-butt weld
C = 0,125 Coulson, Vol 6, Hal. 217 Maka,
t
s
=
  
125 ,
67 ,
19 6
, 8
, 650
. 12
2 480
67 ,
19 
 
 
t
s
= 0,592 in Diambil tebal plate standar =
10 16
in C
P E
f ri
P t
s
 
 6
, .
.
D.49
5. Menentukan Panjang Plate
Untuk  menghitung  panjang  shell,  persamaan  yang  digunakan adalah :
L = Keterangan :
L   = panjang plate, in D
o
= diameter luar shell, in n   = jumlah plate
Weld length  =  Banyak  plate  pada  sekeliling  plate  x  Banyak
sambungan pengelasan vertikal = n x Butt welding
Panjang shell untuk course 1 : D
o
= D
i
+ 2 x t
s
= 480 + 2 x
10 16
= 481,25 in n = 2 buah
Butt welded = 0,156 Brownell and Young, Hal. 254
Maka, L =
= 62,99 ft
n weld
D
o
12. length
- π.
2 12
0,156 2
- 25
, 481
3,14