Workshop - General Battery Shop LeadAcid CAA EEL1-1

Page 160 Part 2 ✈ Chapter 3 - Checklists MRA – 1st Edition September 1998 Part 2 ✈ Chapter 2 - Airworthiness Audit Policy and Procedures References Result A-2 Is there potential for contamination of tools, protective clothing, ventilation, the tester? OK FDG NA A-3 Is the cleaning station segregated? OK FDG NA A-4 Are there spark-proof electrical fittings? OK FDG NA A-5 Does the door open outwards? OK FDG NA A-6 Is protective clothing used? OK FDG NA A-7 Is there bicarbonate for neutralizing? OK FDG NA A-8 Is the battery charger calibrated? OK FDG NA A-9 Describe the ventilation system. OK FDG NA A-10 Is there an emergency station, including a fire extinguisher? OK FDG NA A-11 Describe the lighting. OK FDG NA A-12 Is there proper certification, including records? OK FDG NA A-13 Describe the general shop appearance. OK FDG NA A-14 Are the proper tools such as a gravity tester and distilled water available? OK FDG NA A-15 Is there a panic button? OK FDG NA A-16 Is the maximum room temperature 27° C81° F observed? OK FDG NA A-17 Is there a gono-go connector tester? OK FDG NA Part 2 ✈ Chapter 3 - Checklists Page 161 Part 2 - Airworthiness Audit Policy and Procedures MRA – 1 st Edition September 1998 References Result A-18 Is there proper segregation in the shop and store? OK FDG NA Items Certified - Completed by:

3.13.15 Battery Shop Nicad CAA EEL1-3

References Result A-1 Are both battery shops segregated? OK FDG NA A-2 Is there potential for contamination of tools, protective clothing, ventilation, the tester? OK FDG NA A-3 Is the cleaning station segregated? OK FDG NA A-4 Are there spark-proof electrical fittings? OK FDG NA A-5 Does the door open outwards? OK FDG NA A-6 Is protective clothing used? OK FDG NA A-7 Is there boricacetic acid, lemon juice or vinegar for neutralising? OK FDG NA A-8 Is the battery charger calibrated? OK FDG NA A-9 Is the torque wrench calibrated? OK FDG NA A-10 Are there cleaning facilities i.e. a sink and running water and cleaning tools? OK FDG NA A-11 Describe the ventilation system. OK FDG NA A-12 Is there an emergency station, with a bottle of distilled water, a shower and a fire extinguisher available? OK FDG NA Page 162 Part 2 ✈ Chapter 3 - Checklists MRA – 1st Edition September 1998 Part 2 ✈ Chapter 2 - Airworthiness Audit Policy and Procedures References Result A-13 Are the proper tools a shorting clip, cell puller, vent cap remover, temp switch tester and multi-meter available? OK FDG NA A-14 Is there a vent cap tester? OK FDG NA A-15 Is there proper segregation in the store and shop? OK FDG NA A-16 Is there proper certification, including records? OK FDG NA A-17 Is there cannibalism of scrap cells and parts? OK FDG NA A-18 Is the lighting adequate? OK FDG NA A-19 Describe the general appearance with regard to cleanliness of the shop. OK FDG NA A-20 Is there a panic button? OK FDG NA A-21 Is the maximum room temperature 21° C70° F observed? OK FDG NA Items Certified - Completed:

3.13.16 Shipping

References Result A-1 Is there a shipper? If not, who is in charge of packing and shipping? MPM OK FDG NA A-2 Prior to shipping, are customers requirements checked against the parts being shipped e.g. the part number, quantity and packaging? MPM OK FDG NA