Area 431 Analisis Waktu Antar Kerusakan Mesin Electric Motor menggunakan Metode Failure Finding Interval di PT. Riau Andalan Pulp and Paper (PT. RAPP)
Tabel L5.8. Normal Plot TBF Electric Motor Fiberline Area 431
No t
1
0.1245 1.0000
0.0000
2
21.4186 0.3571
0.6429 0.3661
3
42.7128 0.1429
0.8571 1.0676
4 64.0069
0.0714 0.9286
1.4652
5
85.3011 0.0714
0.9286 1.4652
6
106.5952 0.0000 1.0000
Sumber : Hasil Pengolahan Data
Gambar L5.8. Normal Plot TBF Electric Motor Fiberline Area 431
] t
R ˆ
1 [
z
1
− φ
=
−
t R
ˆ 1
−
t R
ˆ
Tabel L5.9. Lognormal Plot TBF Electric Motor Fiberline Area 431
No t
1
0.1245 -2.0834
1.0000 0.0000
2 21.4186
3.0643 0.3571
0.6429 0.3661
3
42.7128 3.7545
0.1429 0.8571
1.0676
4 64.0069
4.1590 0.0714
0.9286 1.4652
5 85.3011
4.4462 0.0714
0.9286 1.4652
6
106.5952 4.6690 0.0000
1.0000 0.0000
Sumber : Hasil Pengolahan Data
Gambar L5.9. Logormal Plot TBF Electric Motor Fiberline Area 431
t ln
t R
ˆ
t R
ˆ 1
− ]
t R
ˆ 1
[ z
1
− φ
=
−
Tabel L5.10. Gamma Plot TBF Electric Motor Fiberline Area 431
No t
1
0.1245 0.3528
1.0000 0.0000
2 21.4186
4.6280 0.3571
0.6429 0.3661
3
42.7128 6.5355
0.1429 0.8571
1.0676
4
64.0069 8.0004
0.0714 0.9286
1.4652
5 85.3011
9.2359 0.0714
0.9286 1.4652
6
106.5952 10.3245 0.0000 1.0000
0.0000
Sumber : Hasil Pengolahan Data
Gambar L5.10. Gamma Plot TBF Electric Motor Fiberline Area 431
t
t R
ˆ
t R
ˆ 1
− ]
t R
ˆ 1
[ z
1
− φ
=
−
LAMPIRAN 6 Plot Distribusi TTR Electric Motor
1.
Area 411
Tabel L6.1. Eksponensial Plot TTR Electric Motor Fiberline Area 411
No t
1 3.4995
1
2
4.2884 0.3636
-1.0116
3 5.0773
0.2727 -1.2993
4 5.8662
0.1818 -1.7047
5
6.6551 0.1818
-1.7047
6
7.4440 0.0000
Sumber : Hasil Pengolahan Data
Gambar L6.1. Eksponensial Plot TTR Electric Motor Fiberline Area 411
] t
F 1
ln[ −
t F
1 −
Tabel L6.2. Weibull Plot TTR Electric Motor Fiberline Area 411
No t
1 3.4995
0.5440 1
2 4.2884
0.6323 0.3636
-1.0116 0.0115
3
5.0773 0.7056
0.2727 -1.2993
0.2618
4 5.8662
0.7684 0.1818
-1.7047 0.5334
5 6.6551
0.8232 0.1818
-1.7047 0.5334
6
7.4440 0.8718
0.0000
Sumber : Hasil Pengolahan Data
Gambar L6.2. Weibull Plot TTR Electric Motor Fiberline Area 411
t ln
t F
1 −
] t
F 1
ln[ −
]} t
F 1
ln[ {
ln −
−
Tabel L6.3. Normal Plot TTR Electric Motor Fiberline Area 411
No t
1
3.4995
2
4.2884 0.6364
0.3488
3
5.0773 0.7273
0.6046
4 5.8662
0.8182 0.9085
5
6.6551 0.8182
0.9085
6
7.4440 1
Sumber : Hasil Pengolahan Data
Gambar L6.3. Normal Plot TTR Electric Motor Fiberline Area 411
t Fˆ
] t
Fˆ [
z
1 −
φ =
Tabel L6.4. Lognormal Plot TTR Electric Motor Fiberline Area 411
No t
1
3.4995 1.2526
2
4.2884 1.4559
0.3488
3 5.0773
1.6248 0.6046
4
5.8662 1.7692
0.9085
5
6.6551 1.8954
0.9085
6
7.4440 2.0074
Sumber : Hasil Pengolahan Data
Gambar L6.4. Logormal Plot TTR Electric Motor Fiberline Area 411
t ln
] t
Fˆ [
z
1 −
φ =
Tabel L6.5. Gamma Plot TTR Electric Motor Fiberline Area 411
No t
1
3.4995 1.8707
2 4.2884
2.0708 0.3488
3
5.0773 2.2533
0.6046
4
5.8662 2.4220
0.9085
5 6.6551
2.5797 0.9085
6
7.4440 2.7284
Sumber : Hasil Pengolahan Data
Gambar L6.5. Gamma Plot TTR Electric Motor Fiberline Area 411
t ]
t Fˆ
[ z
1 −
φ =